Emerson Rosemount 5081 Quick Start Manual
Emerson Rosemount 5081 Quick Start Manual

Emerson Rosemount 5081 Quick Start Manual

Explosion-proof, single-input intelligent explosion-proof, single-input intelligent transmitter
Hide thumbs Also See for Rosemount 5081:

Quick Links

Quick Start Guide
00825-0100-3581, Rev AA
April 2019
Rosemount
5081
Explosion-Proof, Single-Input Intelligent
Transmitter
loading

Summary of Contents for Emerson Rosemount 5081

  • Page 1 Quick Start Guide 00825-0100-3581, Rev AA April 2019 ™ Rosemount 5081 Explosion-Proof, Single-Input Intelligent Transmitter...
  • Page 2 Emerson products. Failure to follow the proper instructions may cause any one of the following situations to occur: loss of life, personal injury, property damage, damage to this instrument, and warranty invalidation.
  • Page 3: Table Of Contents

    April 2019 Quick Start Guide execute the programming instructions provided by Seller and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expiration of the applicable warranty period. Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller, whichever period expires first.
  • Page 4 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 5: First Steps

    April 2019 Quick Start Guide First steps Unpack and inspect To unpack the instrument: Procedure 1. Inspect the shipping container(s). If there is damage, contact the shipper immediately for instructions. 2. If there is no apparent damage, unpack the container(s). 3.
  • Page 6 Zone 0 environment. Certification standards IEC 60079-0:2011, IEC 60079-11:2011 1.3.2 ATEX ™ Certificate Bas02ATEX1284X (Rosemount 5081A/P) Baseef03ATEX0099X (Rosemount 5081C) Baseefa03ATEX0399X (Rosemount 5081T) Intrinsically safe marking Ex ia IIC T4 Ga (-20 °C ≤ T ≤ +65 °C) Emerson.com/Rosemount...
  • Page 7 April 2019 Quick Start Guide Certification conditions The Rosemount 5081 enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to prevent it from impact or abrasion if located in a Zone 0 environment.
  • Page 8 Class I, Division 2, Groups B, C, D certification T4 T max. 70 °C 4X enclosure type Certification conditions For non-incendive field wiring, see installation drawings 1400676 or 1400677. Certification standards Certified to FM Approvals standards: 3600:2011, 3610:2015, 3611:2016, 3615:2006, 3810:2005, and ANSI/NEMA 250:1991 Emerson.com/Rosemount...
  • Page 9: Wire...............................................................9 Eu Declarations Of Conformity

    April 2019 Quick Start Guide Wire Wiring overview To find wiring diagrams for specific sensors, check the wiring sections of the reference manuals for those particular sensors. Power supply/current loop 2.2.1 Power supply overview The tables below display the minimum and maximum voltages needed to ™...
  • Page 10 Power supply voltage needed to provide 30 Vdc for a 22 mA current Maximum current About 24 mA Minimum load for digital 250 Ohms communications Minimum power supply voltage to 17.5 Vdc supply the 12.0 Vdc lift off voltage at the transmitter Emerson.com/Rosemount...
  • Page 11 April 2019 Quick Start Guide ® ™ 2.2.2 Wire the transmitter with HART or F Fieldbus OUNDATION Procedure 1. Run the power/signal wiring through the opening nearest terminals 15 and 16. 2. Use shielded cable and ground the shield to the power supply. 3.
  • Page 12 Quick Start Guide April 2019 Figure 2-2: General wiring architecture A. Filter B. Terminator C. Trunk D. Spur Emerson.com/Rosemount...
  • Page 13: Display And Operate

    April 2019 Quick Start Guide Display and operate User interface and main display The following are examples of the main (process) display screen (Figure 3-1) and the program display screen (Figure 3-2). Figure 3-1: Main Display Screen A. Conductivity value B.
  • Page 14 Advance to the next sub-menu. menu. 4. PROG 9. EXIT • Access to Program • End current operation. menu. • Return to the first 5. DIAG prompt in the • Access to present sub-menu. diagnostics. • Changes are not saved. Emerson.com/Rosemount...
  • Page 15 April 2019 Quick Start Guide Guidelines for using IRC • Do not use harsh chemicals or abrasive brushes when cleaning the remote control. • If the green LED does not light when you press a key, the issue is probably a weak battery. To restore operation, remove four screws to access and replace the two batteries.
  • Page 16 NONHAZARDOUS AREA. AVERTISSEMENT: LA SUBSTITUTION DE COMPOSANTS PEUT COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE. POUR PREVENIR L'INFLAMMATION D'ATMOSPHERE, NE CHANGER LES BATTERIES QUE DANS DES EMPLACEMENTS DESIGNES NON DANGEREUX. USE ONLY ENERGIZER E92/EN92 OR DURACELL MN2400/PC2400 (2) 1.5 V AAA BATTERIES. Emerson.com/Rosemount...
  • Page 17 April 2019 Quick Start Guide Menu system There are three main menus: Calibrate, Program, and Diagnose. Calibrate and Program menus have additional sub-menus as shown in the figures below. Table 3-1: Program Menu Displayed item Definition OUtpUt Current output menu header Quick Start Guide...
  • Page 18 Current output test value tAUtO Automatic temperature compensation tMAn Manual temperature compensation dISPLAY Display menu header Measurement type tEMP ° C/° F toggle selection OUtPUt Current (mA) or percent of full scale display COdE Access code OFFSt Offset value Emerson.com/Rosemount...
  • Page 19 April 2019 Quick Start Guide Quick Start Guide...
  • Page 20 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 21 April 2019 Quick Start Guide Figure 3-6: HART Contacting Conductivity Menu Tree HART Contacting conductivity menu tree CALIbrAtE Process display screen SEnSOr 0 tEMP AdJ µS/cm 5000 CALIBRATION Mtr CAL 25.0C 12.00mA CELL COnSt CAL key PROG key tEMP SLOPE DIAG key HOLD key OUtPUt CAL...
  • Page 22 25.0C 12.00mA CELL COnSt CAL key PROG key tEMP SLOPE DIAG key HOLD key OUtPUt CAL OutPut tEMP dISPLAY Process Display PROGRAM HArt SEtUP CuST dEFAULT AbS C OFFSt CELL COnSt tSLOPE DIAGNOSTICS CAL F 5081-T-Ht SoFt HArd FaULTs Emerson.com/Rosemount...
  • Page 23 April 2019 Quick Start Guide Quick Start Guide...
  • Page 24 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 25 April 2019 Quick Start Guide Quick Start Guide...
  • Page 26 CALIBRATION 25.0 C Mtr CAL CAL key PROG key CELL COnSt DIAG key HOLD key tEMP SLOPE tEMP dISPLAY Process Display PROGRAM SEtUP CuST dEFAULT AbS C 0 air CELL COnSt tSLOPE DIAGNOSTICS CAL F 5081-C-FF SoFt HArd FaULTs Emerson.com/Rosemount...
  • Page 27 April 2019 Quick Start Guide Figure 3-12: F Fieldbus Toroidal Conductivity Menu Tree OUNDATION Foundation Fieldbus toroidal conductivity menu tree CALIbrAtE SEnSOr 0 5000 µS/cm tEMP AdJ CALIBRATION 25.0C 12.00mA CELL COnSt CAL key PROG key tEMP SLOPE DIAG key HOLD key tEMP dISPLAY...
  • Page 28 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 29: Startup

    April 2019 Quick Start Guide Startup Procedure 1. Using the infrared remote control (IRC), press PROG, NEXT, NEXT, and ENTER in this order. 2. Select the measurement type and unit of measurement. 3. Use the arrow keys to toggle between Celsius and Fahrenheit. 4.
  • Page 30 Quick Start Guide April 2019 EU Declarations of Conformity The following pages are the EU Declarations of Conformity for the ™ Rosemount 5081-C Contacting Conductivity Transmitter, 5081 P/A Amperometric/pH Transmitter, and 5081-T Toroidal Conductivity Transmitter. Emerson.com/Rosemount...
  • Page 31 April 2019 Quick Start Guide Quick Start Guide...
  • Page 32 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 33 April 2019 Quick Start Guide Quick Start Guide...
  • Page 34 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 35 April 2019 Quick Start Guide Quick Start Guide...
  • Page 36: China Rohs Table

    Quick Start Guide April 2019 China RoHS Table Emerson.com/Rosemount...
  • Page 37 April 2019 Quick Start Guide Quick Start Guide...
  • Page 38 Quick Start Guide April 2019 Emerson.com/Rosemount...
  • Page 39 April 2019 Quick Start Guide Quick Start Guide...
  • Page 40 Linkedin.com/company/Emerson- Automation-Solutions The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a twitter.com/rosemount_news mark of one of the Emerson family of companies. Facebook.com/Rosemount All other marks are the property of their youtube.com/RosemountMeasurement respective owners.