About Night Quiet Mode - Daikin R32 Series Installer's Reference Manual

Hide thumbs Also See for R32 Series:
Table of Contents
6
|
Installation
To set the priority room function

6.8.4 About night quiet mode

To turn on the night quiet mode
Installer reference guide
52
Operation mode priority: If the priority room function is set on an indoor unit,
all other indoor units enter the standby mode.
Priority during high-power operation: If the indoor unit on which the priority
room function is set operates at high power, the other indoor units will run with
reduced capabilities.
Quiet operation priority: If the indoor unit on which the priority room function is
set to quiet operation, the outdoor unit will also run quietly.
Ask the customer in which rooms he plans to use this function and make the
necessary settings during installation. Setting it in the guest rooms is convenient.
1 Remove the switch cover on the service PCB.
2 Set the switch (SW4) for the indoor unit for which you want to activate the
priority room function to ON.
1
3 Reset the power.
The night quiet mode function makes the outdoor unit run more quietly at
nighttime. This will reduce the cooling capacity of the unit. Explain Night quiet
mode to the customer and confirm if customer wants to use this mode.
1 Remove the switch cover on the service PCB.
1
2 Set the night quiet mode switch (SW6-1) to ON.
ON
OFF
E
D
C
B
A
E
D
A
2
C
B
A
1
SW4
2
3
4
5
ON
OFF
2
A
1
1
2
2
1
2
SW6
3
4
5
3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1B – 2020.05

Hide quick links:

Table of Contents
loading

Table of Contents