Checking Rectifying Module (On Ac Input Drives Only) - Allen-Bradley PowerFlex 700H Hardware Service Manual

High performance/adjustable frequency ac drive
Hide thumbs Also See for PowerFlex 700H:
Table of Contents
2-14
Component Test Procedures
X3
X4
X5
X6
X7
Should measure -15V dc with respect to DC- with no light in WL cable
Should measure +15V dc with respect to DC- with light in WL cable
Should measure -15V dc with respect to DC- with no light in WL cable
Should measure +15V dc with respect to DC- with light in WL cable
Should measure -15V dc with respect to DC- with no light in UL cable
Should measure +15V dc with respect to DC- with light in UL cable
Should measure -15V dc with respect to DC- with no light in UL cable
Should measure +15V dc with respect to DC- with light in UL cable
Checking Rectifying Module
(on AC Input Drives Only)
Figure 2.3 Opto-Coupler Checks for Right-Hand Output Power Module
Should measure -15V dc with respect to DC- with no light in WH cable
Should measure +15V dc with respect to DC- with light in WH cable
X8
Should measure -15V dc with respect to DC- with no light in WH cable
Should measure +15V dc with respect to DC- with light in WH cable
X9
H8
H6
H4
H9
H7
H5
X8
X9
X10
X11
X10
X12
X13
X14
X15
X1
Important: This procedure requires special equipment and training. Only
qualified and trained personnel should perform these
procedures.
1. Remove power from the drive. Refer to
Drive on page
2. Remove the covers from the power structures. Refer to
Covers from the Power Structures on page
3. On Power Structure #1, visually inspect the pre-charging resistors. If
pre-charging resistors are damaged:
A. Replace the Rectifying Module (See
Output Power Modules and Rectifying Modules on page
B. Check the capacitors, rectifiers and external connections for
short-circuits. (See
C. Check the Output Power Modules (See
and Reverse Biased Diode Tests for Major Power Components on
page
2-4).
Should measure -15V dc with respect to DC- with no light in VH cable
Should measure +15V dc with respect to DC- with light in VH cable
Should measure -15V dc with respect to DC- with no light in VH cable
Should measure +15V dc with respect to DC- with light in VH cable
Should measure -15V dc with respect to DC- with no light in UH cable
Should measure +15V dc with respect to DC- with light in UH cable
Should measure -15V dc with respect to DC- with no light in UH cable
Should measure +15V dc with respect to DC- with light in UH cable
X11
Should measure -15V dc with respect to DC- with no light in VL cable
Should measure +15V dc with respect to DC- with light in VL cable
Should measure -15V dc with respect to DC- with no light in VL cable
Should measure +15V dc with respect to DC- with light in VL cable
3-3.
Checking the DC Bus Capacitors on page
Removing Power from the
Removing the
3-15.
Removing the Right-Side
3-33).
Conducting Forward
2-17)
Table of Contents
loading

This manual is also suitable for:

Powerflex 700s

Table of Contents