Summary of Contents for Emerson Rosemount 1057

  • Page 1 Quick Start Guide 000825-0100-3157, Rev AA September 2018 ™ Rosemount 1057 Single Channel Transmitter...
  • Page 2 Safety Information Read this page before proceeding! Your instrument purchase from Emerson is one of the finest available for your particular application.These instruments have been designed and tested to meet many national and international standards.Experience indicates that its performance is directly related to the quailty of the installation and knowledge of the user in operating and maintaining the instrument.To ensure its...
  • Page 3: Table Of Contents

    September 2018 Quick Start Guide Contents First steps............................. 5 Install............................8 Wire............................. 9 Navigating the display........................14 Start up transmitter........................20 Quick Start Guide...
  • Page 4 Quick Start Guide September 2018 Rosemount 1057...
  • Page 5: First Steps

    1. Inspect the shipping container. If it is damaged, contact the shipper immediately for instructions. 2. If there is no apparent damage, unpack the container. Be sure all items shown on the packing list are present. If items are missing, notify Emerson immediately. Quick Start Guide...
  • Page 6 Figure 1-1: Panel Mounting Dimensions Note The front panel is hinged at the bottom. The panel swings down for easy access to the wiring locations. Panel mounting seal integrity (4/4X) for outdoor applications is the responsibility of the end user. Rosemount 1057...
  • Page 7 September 2018 Quick Start Guide Figure 1-2: Pipe and Wall Mounting Dimensions NOTICE The front panel is hinged at the bottom. The panel swings down for easy access to the wiring locations. Quick Start Guide...
  • Page 8: Install

    3. Keep the transmitter and sensor wiring at least one foot from high voltage conductors. Be sure there is easy access to the transmitter. 4. The transmitter is suitable for panel, pipe, or surface mounting. Refer Figure 1-1 Figure 1-2. Rosemount 1057...
  • Page 9: Wire

    3.1.3 Alarm relays Emerson supplies four alarm relays with the switching power supply (85 to 264 Vac, 03 order code) and the 24 Vdc power supply (20 - 30 Vdc, 02 order code). You can use all relays for process measurement(s) or temperature.
  • Page 10 September 2018 Prepare conduit openings There are six conduit openings in all configurations of the transmitter. Note Emerson fits four of openings with plugs upon shipment. Figure 3-1: Conduit openings A. Front panel/keypad B. Power leads C. Alarm relay leads D.
  • Page 11 3.3.1 Power wiring ™ Emerson offers two power supplies for the Rosemount 1. 24 Vdc (20-30 V) power supply (02 ordering code) 2. 85-265 Vac switching power supply (03 ordering code) AC mains (115 or 230 V) leads and 24 Vdc leads are wired to the power supply board which is mounted vertically on the left side of the main enclosure cavity.
  • Page 12 3.3.3 Alarm relay wiring Emerson supplies four alarm relays with the switching power supply (85 to 265 Vac, 03 order code) and the 24 Vdc power supply (20-30 Vdc, 02 order code). Wire the relay leads on each of the independent relays to the correct position on the power supply board using the printed lead markings (NO/ Normally open, NC/Normally closed, or Com/Common) on the board.
  • Page 13 September 2018 Quick Start Guide COM4 Relay 4 3.3.4 Wire sensor to transmitter Procedure 1. Wire the correct sensor leads to the main board using the lead locations marked directly on the board. 2. After wiring the sensor leads, carefully slide the wired board fully into the enclosure slot and take up the excess sensor cable through the cable gland.
  • Page 14: Navigating The Display

    Help screens are displayed for most Warning fault and warning conditions to guide you in troubleshooting. During calibration and programming, key presses cause different displays to occur. The displays are self-explanatory and guide you step-by-step through the procedure. Rosemount 1057...
  • Page 15 September 2018 Quick Start Guide Instrument keypad There are four function keys and four selection keys on the instrument keypad. Function keys Four top-level menu items appear when you press MENU. • Calibrate: Calibrate the attached sensor(s) and analog output(s). •...
  • Page 16 GI imp 1, 2, 3 • Ref imp 1, 2, 3 • Raw 1, 2, 3 • mV input 1, 2, 3 • Temp 1, 2, 3 • Man temp 1, 2, 3 • Output 1 mA • Output 2 mA Rosemount 1057...
  • Page 17 September 2018 Quick Start Guide • Output 3 mA • Output 4 mA • Output 1% • Output 2% • Output 3% • Output 4% • Measure 1, 2, 3 • Blank Fault and warning banner If the transmitter detects a problem with itself or the sensor, the word will appear at the bottom of the display.
  • Page 18 To select the menu item, press ENTER. To return to a previous menu level or to enable the main live display, press EXIT repeatedly. To return immediately to the main display from any menu level, press MENU and then EXIT. The selection keys have the following functions: Rosemount 1057...
  • Page 19 September 2018 Quick Start Guide The Up key (above ENTER) increments numerical values, moves the • decimal point one place to the right, or selects units of measurement. The Down key (below ENTER) decrements numerical values, moves the • decimal point one place to the left, or selects units of measurement. The Left key (left of ENTER) moves the cursor to the left.
  • Page 20: Start Up Transmitter

    Press ENTER to store a setting. Press EXIT to leave without storing changes. Press EXIT during Quick Start to return the display to the initial startup screen (Select language). 3. Complete the steps as shown in the quick start guide flow diagram, Figure 5-1 Rosemount 1057...
  • Page 21 September 2018 Quick Start Guide Figure 5-1: Quick Start Guide After the last step, the main display appears. The outputs are assigned to default values. 4. To change output and temperature-related settings, go to the main menu and choose Program. Follow the prompts. For a general guide to the Program menu, see Figure 5-2 Quick Start Guide...
  • Page 22 September 2018 Figure 5-2: 1057 Menu Tree 5. To return the transmitter to the factory default settings, choose Reset Analyzer under the Program menu. ™ Please call Rosemount Customer Support Center at 1-800-854-8527 if you need further support. Rosemount 1057...
  • Page 23 September 2018 Quick Start Guide Quick Start Guide...
  • Page 24 Linkedin.com/company/Emerson- Automation-Solutions The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a twitter.com/rosemount_news mark of one of the Emerson family of companies. Facebook.com/Rosemount All other marks are the property of their youtube.com/RosemountMeasurement respective owners.