Program Outputs [53] - Honeywell Galaxy Flex V3 Series Installer Manual

Table of Contents
Galaxy Flex Installer Manual

Program Outputs [53]

Use this option to modify the programming of the outputs on the system. You can also
change the attributes of the outputs. The programmable options are:
Attributes
1 = Output Function
2 = Output Mode
3 = Output Polarity
4 = Diag. Recording
5 = Descriptor
6 = Control
7 = Output Groups
Note: Groups only appear if the Group option is enabled (refer to Groups [63.1]).
Selecting Outputs
RIO Outputs
When you enter the option the first output on the system is displayed with the output address
and function on the top line, and the polarity and assigned groups on the bottom line.
Use
or
to scroll through the outputs, or enter the address of a specific output.
A
B
to programme an output. The first programming attribute 1=Op Function is
Press
ent
displayed.
Control panel outputs
Outputs 1 and 2 on the control panel use addresses 1001 and 1002 respectively
Horn (3)
The horn output is labelled as Output 3 on the PCB. The horn output is fully programmable,
Address
99 -.
Keypad Outputs
The keypad outputs are fully programmable. The address of the keypad output is the keypad
address prefixed with a star, for example the output for keypad 16 is
keypad outputs default to Entry/Exit Horn.
Description
Assign output type
1 = Latch - requires valid code to reset
2 = Reflex - follows activation status of zones
3 = Pulse (1 - 3000 secs) - activates for programmed period
0 = POS – 12 V going to 0 V in activation
1 = NEG – 0 V going to 12 V in activation
Assigns output to be active during Diagnostic Test
Assigns a descriptor of up to 12 characters for each output
1 = Mode (0=OFF, 1=Toggle, 2=Trigger)
2 = Show Status (0=OFF, 1=ON)
Assign groups to the output
Table 6 Output Attributes
Program Outputs [53]