Programming Example - Allen-Bradley 1305 Series User Manual

Adjustable frequency ac drive 0.37 - 4 kw (0.5 - 5 hp) frn 6.01 and up
Table of Contents
Programming
5-4

PROGRAMMING EXAMPLE

The following is an example of the programming steps required to change a parameter setting. In this example, the parameter
[Freq Select 1] is being programmed from its' factory default setting of "Adapter 1" to a new setting, "Adapter 2".
ACTION
❏ 1. Press any key to go from the Status Display to the ''Choose Mode" menu.
ESC
SEL
To Select Mode
❏ 2. Press the Up/Down keys until ''Program" appears on the display.
or
❏ 3. Press the Enter key to go to the ''Program" menu.
To Select a Group
or
❏ 4. Press the Up/Down keys until "Setup" appears on the display.
❏ 5. Press the Enter key to go to the "Setup" menu.
To Select a Parameter
within a Group
❏ 6. Press the Up/Down keys until [Freq Select 1] appears on the display.
or
SEL
❏ 7. Press the SEL key. The first character of line 2 will flash indicating the
To Change a Parameter
Setting or Enter a Value
❏ 8. Press the Up/Down keys until ''Adapter 2" appears on the display.
or
❏ 9. Press the Enter key to program [Freq Select 1] to ''Adapter 2."
DESCRIPTION
parameter setting/value can be changed.
HIM DISPLAY
Stopped
+0.00 Hz
Choose Mode
Program
Choose Group
Setup
Freq Select 1
Remote Pot
Freq Select 1
Adapter 2
Freq Select 1
Adapter 2