Motor Control File - Allen-Bradley PowerFlex 23P User Manual

Digital dc drive
Table of Contents

Motor Control File

Parameter Name & Description
See
page 117
for symbol descriptions
21
[Min Firing Angle]
Specifies the minimum SCR firing angle (Alpha) that the drive can command.
This parameter should only be changed in applications where full speed is
needed with a low AC line or operating in overload.
A
Note: See Parameter 21 [Min Firing Angle] Configuration on page
detailed configuration instructions. This parameter was added for firmware
revision 7.001.
45
[Max Ref Speed]
Highest speed reference that can be commanded. The value of this parameter
also scales external speed reference values (rpm) to internal units (counts),
including analog inputs (10V = Par 45 rpm). Rated motor speed is
determined via Par 456 [Fld Weaken Ratio] when field weakening is used. If
field weakening is not used, set this parameter to the motor base speed.
Notes: If a speed feedback device is used (encoder, resolver, or tachometer),
see Drive Reference and Feedback Scaling on page
maximum value was changed from "16383" for firmware revision 3.001.
162
[Max Feedback Spd]
Specifies the scaling between internal (counts) and external speed feedback
values. Typically, this parameter is set to the same value as Parameter 45
[Max Ref Speed]. If an analog (DC) tachometer is used, this parameter's value
must be set to be compatible with the S4 switches on the control board (see
DIP Switch and Jumper Settings on page 77). If armature voltage feedback is
used, this parameter must be set to the motor nameplate base speed. Set Par
585 [Overspeed Val] 10% higher than the value entered into Par 162. Rated
motor speed is determined via Par 456 [Fld Weaken Ratio] when field
weakening is used. If field weakening is not used, set this parameter to the
motor base speed.
Notes: If a speed feedback device is used (encoder, resolver, or tachometer),
see Drive Reference and Feedback Scaling on page
maximum value was changed from "16383" for firmware revision 3.001.
175
[Rated Motor Volt]
Maximum armature voltage of the drive. Typically, this value is set to the
Motor Nameplate Armature voltage. When Par 469 [Field Mode Sel] is set to 1
"Field Weaken", 4 "Wired FC FW", or 5 "Fiber FC FW" the value in this
parameter equals the voltage at which the field weakening phase begins.
Note: This parameter affects the threshold of an overvoltage condition, as
indicated by an "Arm Overvoltage" fault (F5).
179
[Nom Mtr Arm Amps]
Rated motor nameplate armature current. The settings for the current limit
and the overload function are based on this current value. Also, set this value
to be greater than 1/3 the value of Par 465 [Drive Size].
201
[Drive Type Sel]
Important: This parameter is only applicable to non-regenerative
(2-quadrant) drives.
A
Allows non-regenerative drives to use an external 4-quadrant controller.
• "On" = Ramp, Speed, Torque current references and Speed measurement
have the same behavior as a four quadrant drive.
ATTENTION: When the drive is capable of regenerating power back to the AC line, external inverting fault
protection must be provided in the form of circuit breakers or fuses. Failure to provide this protection could result in
machine or equipment damage.
296
for instructions. The
296
for instructions. The
ATTENTION: Failure to set this parameter to a value appropriate for the intended application could result in
equipment damage and/or personal injury.
Rockwell Automation Publication 20P-UM001M-EN-P - November 2017
Values
Default:
25
Min/Max:
5/ 25
Units:
Deg
320
for
Default:
1750
Min/Max:
1 / 6000
Units:
rpm
Default:
1750.00
Min/Max:
1.00 / 6000
Units:
rpm
Default:
240.0
Min/Max:
20.0 / 999.0
Units:
V
Default:
Based on drive current rating
Min/Max:
0.10 / Based on drive current rating
Units:
A
Default:
0 =
Options:
0 =
1 =
Programming and Parameters
Chapter 3
16-bit
Int
32-bit
Int
Real
Real
Real
"Off"
16-bit
Int
"Off"
"On"
165
2,
456
169,
414,
456,