1.

Restoring the Panel to Factory Default Settings

1.
2.
3.
4.
5.
6.

Resetting the Panel

1.
1
1
S2
Selection
Off
RS-485_2 termination (EOL) DISABLED
(Default)
On
RS-485_2 termination (EOL) ENABLED (Future)
Both DIP Switch 1 and DIP Switch 2 need to be either On or Off to be properly
configured.
Note
When you use the DIP switches to reset a panel to the original factory default
values, the Event History is lost and any customzed databases are removed.
So the panel is reset with the original factory default database. This does not
affect the Ethernet IP address.
Note
You can also use the ASCII command _I=pn_R to reset a panel to the original
factory default values, but this command only removes the customized
databases and restores the original factory default database. The Event
History is retained.
Make a note of the existing settings on SW1 DIP switches.
While the panel is powered up, turn all of the DIP switches to the OFF position.
Power down; then power the panel back up.
Wait for the panel to come up. The RUN LED should flicker fast.
Set the DIP switches back to their original positions.
Power down; then power the panel back up. The RUN LED should flash normal.
The panel is now reset to the original factory default values.