GENERAL
IdentIPoint™ is an intelligent smart card based access control
system that integrates with Enterprise Buildings Integrator™
(EBI) to provide a secure, scalable and a cost effective
solution for securing defense installations, airports, and
buildings. This document describes how to install and
configure the IdentIPoint system.
Fig. 1. IdentIPoint system architecture
INSTALLATION INSTRUCTIONS
Put Bar Code Here
95−7767
Table of Contents
loading

Summary of Contents for Honeywell IdentIPoint

  • Page 1 Honeywell IdentIPoint™ Intelligent Smartcard System INSTALLATION INSTRUCTIONS GENERAL IdentIPoint™ is an intelligent smart card based access control system that integrates with Enterprise Buildings Integrator™ (EBI) to provide a secure, scalable and a cost effective solution for securing defense installations, airports, and buildings.
  • Page 2: Before Installation

    NOTE: Any currently available IdentIPoint reader can be used as an enrollment reader. All the IdentIPoint readers are designed to work with an optional remote IOM. The IOM is used when the control inputs and outputs of the door are desired to be on the secure side of OVERVIEW the door - for high security installations.
  • Page 3 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM WARNING Fire Safety and Liability Notice: Never connect card readers to any critical entry, exit door, barrier, elevator or gate without providing an alternative exit in accordance with all fire and life safety codes pertinent to the installation. These fire and...
  • Page 4: Drywall Mounting

    Input Power Supply earth or common Gang Box (concrete wall) Mounting ground available nearby. 1. Fig.2 and Fig.3 show the parts of the IdentIPoint reader. Ensure that the correct sized gang box is securely WARNING embedded in the concrete wall. The holes provided in...
  • Page 5 ON BACK-PLATE (4) HOLE FOR SECURING HOLE FOR SECURING READER TO BACK- READER TO BACK- PLATE (1) PLATE (1) BACK-PLATE BACK-PLATE KEYPAD KEYPAD READER FRONT READER FRONT Fig. 2. Parts of IdentIPoint reader - Front of reader and Back-plate 95-7767...
  • Page 6 HOLE FOR TAMPER- RESISTANT SCREW RESISTANT SCREW READER BACK READER BACK Fig. 3. Parts of IdentIPoint reader - Back of reader CUT AN OPENING IN THE DRYWALL FOR ROUTING THE WIRES THE OPENING MUST WIRES. THE OPENING MUST HAVE THE SAME DIMENSIONS AS THAT IN THE BACK-PLATE.
  • Page 7 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM GANG BOX EMBEDDED IN WALL USE THE SCREWS PROVIDED TO FIX THE READER BACK- PLATE TO THE EMBEDDED PLATE TO THE EMBEDDED GANG BOX. NOTE: USE A MINIMUM OF 2 SCREWS IN THE HOLES CIRCLED IN RED TO FASTEN THE BACK-PLATE Fig.
  • Page 8 AT THE BACK OF THE READER AS SHOWN Fig. 7. Plugging the connectors into the IdentIPoint reader NOTE: Square ferrite clip is required for the unit to limit emissions within FCC part 15 Class B level. Should be clipped on the reader's Ethernet pigtail and accommodated behind the drywall or inside the gang box. The connector wire colors shown above are only indicative.
  • Page 9 M a n u fa ctu re d : 2 0 0 9 .0 7 .1 3 2 0 0 9 .0 7 .1 3 MADE I N MADE I N CHINA CHINA Fig. 8. Aligning IdentIPoint reader with back-plate before mounting it 95-7767...
  • Page 10 DOWNWARDS UNTIL IT HOOKS INTO PLACE HOOKS INTO PLACE FIRMLY FIRMLY READER ASSEMBLY – READER ASSEMBLY – READER ASSEMBLY – READER ASSEMBLY – SIDE VIEW SIDE VIEW FRONT VIEW FRONT VIEW Fig. 9. Mounting IdentIPoint reader on the back-plate 95-7767...
  • Page 11 USE THE ALLEN USE THE ALLEN WRENCH TO WRENCH TO SECURE THE SECURE THE READER TO THE READER TO THE BACK-PLATE WITH BACK-PLATE WITH THE TAMPER- THE TAMPER- RESISTANT SCREW RESISTANT SCREW Fig. 10. Securing the IdentIPoint reader to the back-plate 95-7767...
  • Page 12 NOTE: • To install IdentIPoint devices in place of older devices that have been removed, you may use the • The IOM can be mounted either on a drywall or on a TRADELINE®...
  • Page 13 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM tances. Connect the wire terminals to the ends of the WARNING wires and plug the wire terminal(s) in their correct slots on the PCB. See Fig.16. For IOM connection details see Make all electrical field connections to reader and Fig.18 and Table.8.
  • Page 14 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM POWER, POWER, FRONT COVER FRONT COVER BACK HALF OF BACK HALF OF DATA AND DATA AND OF THE IOM OF THE IOM THE IOM THE IOM TAMPER TAMPER INDICATION INDICATION LEDS LEDS Power Power Data...
  • Page 15 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM IOM BACK HALF - OPEN IOM BACK HALF - OPEN HOLE FOR HOLE FOR TAMPER- TAMPER- RESISTANT RESISTANT SCREW SCREW BACK KNOCK- BACK KNOCK- OUTS FOR CABLE OUTS FOR CABLE HOLES (2) HOLES (2) COVER TAMPER...
  • Page 16 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM CUT OPENINGS IN THE DRYWALL FOR ROUTING THE WIRES. THE OPENINGS MUST HAVE THE SAME DIMENSIONS AS THAT IN THE BACK HALF OF THE IOM. PUNCH THREE HOLES IN THE DRYWALL FOR THE SCREWS USE THE SCREWS...
  • Page 17 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM GANG BOX EMBEDDED IN WALL PUNCH ADDITIONAL HOLES IN THE WALL FOR THE OTHER SCREWS USE THE SCREWS PROVIDED TO FIX THE BACK HALF OF IOM TO THE GANG BOX AND THE WALL. NOTE: USE ALL 3 SCREWS TO FASTEN THE IOM Fig.
  • Page 18 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM ROUTE THE WIRES ROUTE THE WIRES THROUGH THE KNOCK - THROUGH THE KNOCK - OUT HOLES AND FIX OUT HOLES AND FIX THEM TO THE CORRECT THEM TO THE CORRECT TERMINALS ON THE PCB TERMINALS ON THE PCB...
  • Page 19 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM USE THE ALLEN USE THE ALLEN WRENCH TO WRENCH TO SECURE THE FRONT SECURE THE FRONT COVER OF THE IOM COVER OF THE IOM TO THE BACK HALF TO THE BACK HALF WITH TAMPER- WITH TAMPER-...
  • Page 20 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Posi on Posi on Descrip on Descrip on Address value 1 Address value 1 Address value 2 Address value 2 Address value 4 Address value 4 S2: Ini aliza on Address value 8 Address value 8...
  • Page 21: Power Supply Recommendations

    HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Mounting and Installing the Power FOR IOM 1. Power must be provided to the IdentIPoint IOM from a Supply UL294 and/or UL1076 listed power supply for access control or one approved by local authority having juris- diction.
  • Page 22: General Descriptions

    Digital Inputs or Supervisory Inputs. See Figures Power to the Reader: 25 through 28. Power can be supplied to the IdentIPoint reader either via the Wire the Readers and IOM Ethernet cable when it is connected to a router/switch that is equipped with PoE (Power over Ethernet) PSE (Power Supply 1.
  • Page 23: Power Wiring

    HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Power Wiring 3. Connect the +ve and -ve of wires to IdentIPoint devices. For readers, connect the +ve to the red and the -ve to IMPORTANT the black wires of the 9-pin Molex terminal respectively.
  • Page 24 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM ALL WIRING MUST CONFORM TO APPLICABLE LOCAL NOTE: FOR COMMUNICATION CIRCUITS AND OTHER CODES, ORDINANCES, AND REGULATIONS. APPLICABLE WIRING CIRCUITS WHERE WIRING ENTERS AND EXITS THE BUILDING, REFER TO DO NOT ROUTE COMMUNICATION WIRES WITH POWER TABLE 13 FOR APPROPRIATE LIGHTNING PRO- OR LOCKING DEVICES.
  • Page 25 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Table 3. PoE Modes Model A Model B Vport positive Vport positive Vport negative Vport positive Vport positive Vport negative Vport negative Vport negative Table 4. PoE pin-outs for the two modes. STANDARD SOURCE LOAD...
  • Page 26 Min. 18 AWG Signal – Min. 18 AWG Fig. 21. Connections for single reader with REX and without IOM In the above configuration, one IdentIPoint reader operates in 3. Connect pin(s) 3/4/5 (Relay-C/Relay-NC/Relay-NO) of stand-alone mode to control door access. It authenticates port J9 to the door lock depending on the type of lock users as well as releases the door lock using its relay contact.
  • Page 27 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM NOTE: REX and Door Sense support only Normally Closed and not Normally Open positions, i.e., REX is detected when SAI switch is open, Door is sensed as open when SAI switch is open. Single Reader with REX and IOM...
  • Page 28 • The RS485 ground signal is not necessary if the IOM RS485 Communication and Termination Setting of Con- is powered by the IdentIPoint reader or if there is a nector and Switch Descriptions topic for details on common ground available between the two units.
  • Page 29 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Two Readers with IOM Secure Side Connec ons on Out- on In-reader Ethernet To LAN Ethernet Power-OUT Power-OUT SAI-1-GND SAI-1-GND * 1KΩ for 12V SAI-1 Power-GND 2KΩ for 24V SAI-1 Power-GND SAI-0-GND RS485-A SAI-0-GND RS485-A...
  • Page 30 • The RS485 ground signal is not necessary if the IOM details on power supply connections. is powered by the IdentIPoint reader or if there is a 3. Connect the RS485-A, RS485-B and RS485-GND (pins common ground available between the two units.
  • Page 31 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Reader with Multiple IOMs To LAN Ethernet Ethernet SAI-1-GND Power-OUT Frame-GND Frame-GND Power-IN Power-IN SAI-2-GND SAI-2-GND Power-GND Power-GND SAI-1 Power-GND SAI-2 SAI-2 Relay-C Relay-C SAI-0-GND RS485-A DOGnd DOGnd Relay-NC Relay-NC RS485-B SAI-0 – Relay-NO Relay-NO...
  • Page 32 • The RS485 ground signal is not necessary if the IOM sponding RS485 points on J14 of IOM1. See section is powered by the IdentIPoint reader or if there is a RS485 Communication and Termination Setting of Con- common ground available between the two units.
  • Page 33 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM 1. Connect 12VDC+ of the power supply to pin 5 (Relay- NOTE: The above describes one way of wiring the strike NO) or pin 3 (Relay-C) of the reader and 12VDC- to the latch. Wiring must be done strictly as per the -ve pin of the strike latch.
  • Page 34: Magnetic Lock

    HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Magnetic Lock Magnetic lock connected directly to the reader: LEGEND Power – Min. 18 AWG Power Gnd – Min. 18 AWG Ethernet Power-OUT SAI-1-GND SAI-1 Power-GND SAI-0-GND RS485-A DC – Power 12VDC/24VDC RS485-B SAI-0 RS485-GND...
  • Page 35 For description of IOM pins refer to Table.8. Such a termination circuit can be connected to the SAI of an IdentIPoint reader as well as the IOM. This loop can detect tampering by shorting across or cutting the loop. Four states can be detected by the IdentIPoint device: open, short, cut and closed.
  • Page 36 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM 1K Ω SAI-n Sensor Switch SAI-n GND Fig. 29. Connections for Supervisory Analog Inputs NOTE: REX and Door Sense support only Normally Table 6. Reader J10 connector signals Closed and not Normally Open positions, i.e., REX is detected when SAI switch is open, Door is sensed as open when SAI switch is open.
  • Page 37 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM For IOM: Table 8. IOM Connector Signals Connector Signal Description Connector: J1 12V DC Power 12VDC Power Input, tolerate up to 28VDC Power Ground Power Ground Connector J2 Supervisory Analog Output, repeats the input of SAI-3...
  • Page 38 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Connector Signal Description DO-1-GND Digital Output 1 Ground Connector J12 RL-0-Com Relay 0 Dry Contact Common RL-0-NO Relay 0 Dry Contact Normal Open RL-0-NC Relay 0 Dry Contact Normal Close Connector J13 RL-1-Com Relay 1 Dry Contact Common...
  • Page 39 RS485 is a 2-wire balanced multi-drop serial bus, which allows a master unit to send and receive data to and from its slave units. When an IdentIPoint reader is connected to one or more IOMs, the reader is the master unit while the IOMs are the slave units.
  • Page 40 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Reader (Master) Reader (Master) Reader (Master) Reader (Master) IOM (Slave 1) IOM (Slave 1) IOM (Slave 1) IOM (Slave 1) IOM (Slave 2) IOM (Slave 2) IOM (Slave 2) IOM (Slave 2) Termination ON Termination ON...
  • Page 41: Configuring The Hardware

    HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM IOM Address = 1 IOM Address = 2 IOM Address = 3 IOM Address = 4 Fig. 32. IOM Address set up - S3 Settings CONFIGURING THE HARDWARE The LEDs at the back of the reader glow as follows when power is applied to the device: •...
  • Page 42 • If no LCD screen, or some distance to the reader, then use the IdentIPoint Sync Application to discover the reader Wi-fi: • Need to create an ad-hoc network with the IdentIPoint reader • IP address of IdentIPoint is 192.168.0.200 NOTE: •...
  • Page 43 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM Out-of-the-box assumes that there is no IO Module. 1. If an IO Module is used, simply click the link and follow the prompts as shown in figures labeled 1 through 5. 2. Position 8 of this switch is the IOM setup "dip switch.
  • Page 44 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM 3. Slide it down as shown to turn it ON. Door 1. Select the door IO addresses. 2. Enter door timings. 3. Enter door behavior. Hint — If common wiring & behavior it is quicker to do this from EBI later.
  • Page 45 MAINTAINING THE IDENTIPOINT READERS System health tests All system health tests described in this section can be performed from the IdentIPoint device web pages. See Configuring the Hardware topic for details on accessing the Finishing same. 1. Logout of the webpage.
  • Page 46: Lightning Protection

    3. When the LED/LCD is off, release the factory reset Secondary Protection switch. 4. Wait for the reader to restart. 14507678-004 Ethernet Port Surge Protector 5. If using an LCD model, the Honeywell banner will appear on the display for a few seconds and then disap- pear. 95-7767...
  • Page 47 HONEYWELL IDENTIPOINT™ INTELLIGENT SMARTCARD SYSTEM CERTIFICATIONS WARNING Any changes or modifications not expressly READERS approved by the party responsible for compliance • CE could void the user's authority to operate the • C-tick equipment. • IP-65 (Basic Outdoor Version Only) This device complies with part 15 of the FCC Rules.
  • Page 48: Other Trademarks

    Support and other contacts In no event is Honeywell liable to anyone for any indirect, incidental, special or consequential damages. For technical assistance, call your nearest Honeywell office. The information and specifications in this document are Feedback subject to change without notice.