Menu 11: General Drive Set-Up - Emerson 2202 Advanced User's Manual

Commander sk series ac variable speed drive for 3 phase induction motors from 0.25kw to 110kw, 0.33hp to 150hp
Table of Contents
Parameter
Menu 11
Introduction
x.00
10.12

Menu 11: General drive set-up

Table 10-22 Menu 11 parameters: single line descriptions
Parameter
11.01
Pr 61 set-up
11.02
Pr 62 set-up
11.03
Pr 63 set-up
11.04
Pr 64 set-up
11.05
Pr 65 set-up
11.06
Pr 66 set-up
11.07
Pr 67 set-up
11.08
Pr 68 set-up
11.09
Pr 69 set-up
11.10
Pr 70 set-up
11.11
Not used
11.12
Not used
11.13
Not used
11.14
Not used
11.15
Not used
11.16
Not used
11.17
Not used
11.18
Not used
11.19
Not used
11.20
Not used
11.21
Customer defined scaling
11.22
Parameter displayed at power up
11.23
Serial comms address
11.24
Modbus RTU / user serial mode
11.25
Serial comms baud rate
11.26
Silent period extension
11.27
Drive configuration
11.28
Not used
11.29
Software version
11.30
User security code
11.31
Not used
11.32
Maximum heavy duty drive current rating
11.33
Drive voltage rating
11.34
Software sub-version
11.35
DSP software version
11.36
Not used
11.37
Not used
11.38
Not used
11.39
Not used
11.40
Not used
11.41
Status mode timeout
11.42
Parameter copying
11.43
Load defaults
11.44
Security status
11.45
Select motor 2 parameters
11.46
Defaults previously loaded
11.47
PLC ladder program enable
11.48
PLC ladder program status
11.49
Not used
11.50
PLC ladder program maximum scan time
138
Parameter
Keypad and
description format
display
communications
{71}
{72}
{73}
{74}
{75}
{76}
{77}
{78}
{79}
{80}
{24}
{44}
{43}
{05}
{45}
{25}
{28}
{29}
{10}
{59}
{60}
www.controltechniques.com
Serial
CT Modbus
PLC Ladder
RTU
programming
Range
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
Pr 1.00 to Pr 21.51
0.000 to 9.999
OFF(0) or On(1)
0 to 247
0 to 4
2.4(0), 4.8(1), 9.6(2),
19.2(3), 38.4(4)
0 to 250 ms
AI.AV(0), AV.Pr(1), AI.Pr(2),
Eur:AI.AV(0)
Pr(3), PAd(4), E.Pot(5),
USA: PAd (4)
tor(6), Pid(7), HVAC(8)
0.00 to 99.99
0 to 999
0.00 to 290.00 A
0 to 3
0 to 99
0.0 to 9.9
0 to 250 s
no(0), rEAd(1), Prog(2),
boot(3)
no(0), Eur(1), USA(2)
L1(0), L2(1), L3(2), LoC(3)
OFF(0) or On(1)
0 to 2
0 to 2
-128 to 127
0 to 65535 ms
Advanced parameter
CTSoft
Menu 0
descriptions
Default
Setting
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
1.000
OFF(0)
1
1
19.2(3)
2
Edit mode exit
0
240
no(0)
Edit mode exit
no(0)
Edit mode exit
L1(0)
Edit mode exit
OFF(0)
0
0
User program
Commander SK Advanced User Guide
Issue Number: 9
Update Rate
B
B
B
B
B
B
B
B
B
B
B
N/A
B
B
B
B
N/A
B
N/A
N/A
N/A
N/A
B
B
BW
BR
BW

Hide quick links:

Table of Contents
loading

Table of Contents