Section 5; Data Field Descriptions; About Data Field Programming; Programming Data Fields - Honeywell VISTA-128BPT Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

About Data Field Programming

The following pages list this control's data fields in numerical order. Field numbers are listed in the left column, followed
by a "Title and Data Entries column, which lists the valid entries for each field. Experienced installers can simply follow
this column when programming the data fields. The "Explanation" column provides explanatory information and special
notes where applicable.
NOTE: Refer to the Programming Guide for the default values. They are not listed in this section.
Use the Programming Guide to record the data for this installation.
NOTE: All references in this manual for number of zones, number of user codes, number of access cards,
and the event log capacity, use the VISTA-250BPT's features. See SECTION 1: General Description for the
table listing the differences between the VISTA-128BPT and the VISTA-250BPT control panels. All other
features are identical.

Programming Data Fields

Data field programming involves making the appropriate entries for each of the data fields. Start Data Field
programming by entering the installer code + 8 + 0 + 0 + 0.
FIELD
TITLE and DATA ENTRIES
∗ ∗ ∗ ∗ 00
Installer Code
Enter 4 digits, 0-9
∗ ∗ ∗ ∗ 04
Enable Random Timers For
Partitions 1-8
0 = disable
1 = enable
∗ ∗ ∗ ∗ 05
System Events Notify
0 = disable
1 = enable
∗ ∗ ∗ ∗ 06
Quick Exit (partition-specific)
0 = disable
1 = enable
U L
Quick Exit is not permitted for use with the VISTA-128BPT/VISTA-250BPT Control Panel in a UL installation.

Data Field Descriptions

EXPLANATION
The Installer Code is a 4-digit code reserved for installation company use.
This is the only code that can be used to enter the Program Mode from the
keypad. This code cannot be used to disarm the system if it isn't used to arm
the system. This code cannot be used to re-enter Program Mode if Program
Mode is exited by the ∗98 command.
If enabled, the activation time of the window is randomized up to 30 minutes
and is initialized by either of two methods:
User Code + [#] + [41] Initiates the random schedule for all devices in the
partition.
User Code + [#] + [42] Initiates the random schedule for all devices in the
partition with a time window within 6 PM and 5 AM.
If enabled the system sends notification messages via the RS232 port (TB4).
Field ∗14 must be set for RS232 port (1).
NOTE: If enabled, the system also sends fault and restore messages via the
RS232 port (TB4).
NOTE: While in a communication session with Compass, system events will
not operate.
If enabled, allows users to exit the armed partition without disarming and then
rearming the partition.
Quick Exit is initiated by entering [#] + [9]. This restarts the exit delay. All rules
of exit apply, including exit error logic.
S E C T I O N
5
5-1
Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia

Table of Contents