The Honeywell/Ademco Vista 128BPT, 250BPT are security panels that integrate with the g! system
using an RS-232 serial connection. The panel has an on board serial interface to enable the RS-232
communication between the g! system controller and the control panel.
Integration of the security system provides monitoring and control from any touch screen or computer
both locally and remotely. Additionally, events occurring in the security system can trigger system
commands in other sub-systems in the home. For example, a burglar alarm can turn all the lights on and
send out email alerts.
T
HESE PANELS SUPPORT THE FOLLOWING FEATURES
Arm – Disarm: Arm and disarm from the Viewer interface is supported for all partitions and user codes.
Status information is available for all partitions.
Zone Status: Zone status information is available for all zones (in any partition), and is properly shown in
the Viewer. See exceptions below.
History View: The history view is properly supported on any Viewer.
Auto Zone and Partition Detection: The g! system will automatically detect zones and partitions upon
connection to the panel.
T
HESE PANELS DO NOT SUPPORT THE FOLLOWING FEATURES
Zone Bypass: Zones cannot be bypassed from the g! interface, only from the Ademco keypads. In the
Ademco panel zones can be configured to automatically bypass if they are faulted when arming the
panel. Using this feature works well to overcome this limitation.
Auto Arm: Arming as a System Command from the Event Mapper is not supported with this panel.
Zone Status: Zone status information for entry and exit zones is not communicated to g! during entry
and exit delays.
Entry/Exit Delay: This panel will not notify g! that it is in entry or exit delay, as a result entry/exit delay as
a System Trigger or Condition and Announce Security Events is not supported with this panel.
Relays: The relays on the panel can not be controlled from the g! interface or the Event Mapper.
Panic Button: The g! interface cannot send a panic command to the Ademco panel.
See Communication Details for warnings about BPT communication experiences.
Any feature not specifically noted as supported should be assumed to be unsupported.
ELAN Home Systems ● 1690 Corporate Circle ● Petaluma, CA 94954 USA
tech support: 800.622.3526 • main: 760.710.0990 • sales: 877.289.3526 • email: [email protected]
©2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.
Honeywell/Ademco
VISTA–128BPT, VISTA–250BPT
g! Core Module 5.9.26 or newer
8/6/2013
F
EATURES
:
:
Integration Note
loading

Summary of Contents for Honeywell Ademco VISTA-128BPT

  • Page 1 UPPORTED EATURES The Honeywell/Ademco Vista 128BPT, 250BPT are security panels that integrate with the g! system using an RS-232 serial connection. The panel has an on board serial interface to enable the RS-232 communication between the g! system controller and the control panel.
  • Page 2 7. Test the arming and disarming capability from a computer or touch screen and confirm history function. OMMUNICATION ETAILS Honeywell BPT series panels have some performance and integration features that dealers should be aware of:  Entry/Exit delay: BPT Panels do not communicate Entry/Exit Delays or Entry/Exit zone faults during an Entry/Exit delay.
  • Page 3: Wiring Diagram

    IRING IAGRAM 1: U J9 C PTION ONNECTOR ILL OF ATERIALS D ev ic e M anuf a ct urer P art N um be r P ro t o c o l C o nne ct o r T ype N o t e s A larm Panel Ho neywell-Ademco 1 28BPT,250BP T...
  • Page 4 2: U TB4 T PTION ERMINAL TRIP Pin Out (568B) Blue White/Blue Green ILL OF ATERIALS D ev ic e M anuf a ct urer P art N um be r P ro t o c o l C o nne ct o r T ype N o t e s A larm Panel Ho neywell-Ademco 1 28BPT,250BP T...
  • Page 5 ANEL ROGRAMMING Before communication can start between the g! system and the Ademco panel there are several fields that need to be changed in the panel configuration. You will need the installer access code to enter the programming mode. To enter programming mode press the installer code and then [8000]. Once in programming mode, changing the value of a field can be accomplished by pressing [*] + [Field #] + [ Value ].
  • Page 6 Communication Devices Name Type Serial Port Communication Type Standard Connection (Not Required) Location (Default: Secuirty) Comm Device Name...
  • Page 7 OMMON ISTAKES 1. Serial connections on both TB4 and J9. Only one of these connectors may be used. J9 with a VT-SERCBL is recommended. 2. Incorrect Settings for zone numbering. If duplicate zones/wrong zone numbers are auto- populating in the system, check the Security Panel Settings field. (6.2 and newer builds only) 7 of 7...