Philips Showline SL STRIP 10IP User Manual

Philips Showline SL STRIP 10IP User Manual

Led luminaire
SL STRIP 10IP
LED LUMINAIRE
Table of Contents
loading

Summary of Contents for Philips Showline SL STRIP 10IP

  • Page 1 SL STRIP 10IP LED LUMINAIRE...
  • Page 2 Document Number: SL STRIP 10IP LED Luminaires User Manual Version as of : 17th Sep 2015 SL STRIP 10IP User’s Manual 2015...
  • Page 3: Warnings And Notices

    SL STRIP 10IP IMPORTANT INFORMATION Warnings and Notices When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not mount near gas or electric heaters. c. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
  • Page 4: General Information

    SL STRIP 10IP GENERAL INFORMATION Thanks for your purchasing Showline SL STRIP 10IP lighting equipment, the SL STRIP 10IP is compatible of both DMX & RDM and with 10 channel LED intensity adjustable. Programs can be updated via RDM interface. It is available in master and slave control connection.
  • Page 5: Accessories Included

    SL STRIP 10IP Accessories(Included): 1. Wing screw(2pcs) 2. Mounting Assemble(2pcs) MAIN FEATURES 01 pixel, 02 pixel, 05 pixel,10 pixel DMX Channels selection 0.5m power / signal cable with bare end 10 built-in programs subject to Speed and Dimmer 0-255 dimming level Standard DMX-512 and RDM protocol 01 Thru 99 Chase Speed adjustment Power failure memory...
  • Page 6: System Connection

    SL STRIP 10IP Power: Before plugging your unit in, be sure the resource voltage in your area matches the unit required voltage. Because the line voltage may vary from venue to venue, you should be sure to plug the socket into a matching wall outlet before attempting to operate your unit.
  • Page 7: Layout Overview

    SL STRIP 10IP Layout Overview Rear Panel Overview POWER INPUT (15A Max.) POWER INPUT(输⼊电压): 110-240V~, 50/60Hz; CAUTION / ATTENTION: SL STRIP 10IP POWER CONSUMPTION(功耗): 150W Max. RISK OF ELECTRIC SHOCK DO NOT OPEN 0.2m 40 C RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR Minimum safety distance to flammable materials: 0.2m.
  • Page 8: Operation Modes

    SL STRIP 10IP OPERATION MODES The “SL STRIP 10IP” has four different operation modes. It can be used as a 01 pixel, 02 pixel, 5 pixel, 10 pixel channel DMX dimmer. Please follow illustrations below to operate the unit in your desired mode. Function Parameter Parameter Value...
  • Page 9 SL STRIP 10IP SL STRIP 10IP DMX Mapping (RGBW 16 Bit Mode) SL STRIP 10IP DMX Mapping (RGBW 8 Bit Mode) Red_1-10 Green_1-10 Blue_1-10 White_1-10 OPERATION MODES...
  • Page 10: Chase Mode

    SL STRIP 10IP 1. Setting DMX Address Press the “MODE’ button to select and activate “DMX” menu. In this menu, you can set the DMX address, DMX Bit, DMX Fade DMX Addr and DMX Channel. Press the “MENU” button to select and enter Addr:512 MODE DOWN...
  • Page 11: Manual Mode

    SL STRIP 10IP 2. Chase Speed Menu: Chase Press “MENU’ button to select and activate “Chase Speed” Speed:01 MODE DOWN MENU menu. In this menu, you can adjust the program chase speed. Use the "UP " and "DOWN" buttons to adjust the chase speed from 01 thru 99.
  • Page 12 SL STRIP 10IP RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with SL STRIP 10IP. Table 1: SL STRIP 10IP RDM Parameter IDs SL STRIP 10IP 0x1000 0x0105 Philips Entertain. Lighting Asia SL STRIP 10IP RDM PARAMETER IDS...
  • Page 13 SL STRIP 10IP Table 1: SL STRIP 10IP RDM Parameter IDs RDM PARAMETER IDS...
  • Page 14 SL STRIP 10IP Table 2: SL STRIP 10IP Manufacturer Status IDs Manufacturer Defined Status IDs Manufacturer Specific messages are in the range of 0x8000 —0xFFDF. Each Manufacturer-specific Status ID shall have a unique meaning, which shall be consistent across all products having a given Manufacturer ID.
  • Page 15: Program Update

    SL STRIP 10IP PROGRAM UPDATE Programs of this device can be updated via the RDM interface with proper tool named SC-NODE and RDM Program Tool. Connect the SL STRIP 10IP to the output terminal of the SC-NODE then connect the SC-NODE to the PC, run the TCP/IP setting, see the following figures for details. After the TCP/IP is set, run the RDM_Program_Tool.exe software, the tool will search RDM devices automatically for the first time, user may also search devices via ArtTod Control command.
  • Page 16: Technical Specifications

    SL STRIP 10IP TECHNICAL SPECIFICATIONS LED Source 10 pcs 4in1 RGBW (RGB+Cool White) Beam Angle 6 Degrees Power Thru/Input AC110~240V, 50/60Hz Control Protocols DMX512 (1990) / DMX512A (RDM) / On-Board Menu IP Rating IP65 Power Consumption 150W Max. Weight 7.5Kg Dimension 1077(L)*120(W)*201(H)mm.
  • Page 17 Sh wline Philips Entertainment Lighting Asia PELA Unit C , 14/F, Roxy Industrial Centre,NO. 41-49, Kwai Cheong Road,Kwai Chung, N.T.Hong Kong Tel: +(852)2796 9786 Fax: +(852)2798 6545 Philips Group 2014 All rights reserved. The Company reserves the right to make any variation in design or construction to the equipment described.

Table of Contents