Ec1: Water Fill Solenoids Blocked - Electrolux EWM25 series Service Manual

Washing machines & washer-dryers
Hide thumbs Also See for EWM25 series:
Table of Contents
EC1
The flowmeter detects water filling even if the solenoid is not controlled
Checks to perform:
Does the
appliance fill in
water when the
main switch is off?
YES
Open the drawer
and check which
solenoid leaks and
replace it.
Restart the
diagnostic cycle to
check for further
alarms.
Version WM
Across J8-1 and J8-3 bleach solenoid
Across J9-1 and J9-3 wash solenoid
Across J9-4 and J9-6 prewash solenoid
Version WD
Across J8-1 and J8-3 condensation solenoid
Across J9-1 and J9-3 wash solenoid
Across J9-4 and J9-6 prewash solenoid
07-2010 SOI/DT-mdm FCPD-dp Quality-fz

EC1: Water fill solenoids blocked

Check that all the connectors are inserted correctly
As soon as the
appliance is switched
NO
on does the solenoid
start to fill water?
Open the drawer and check which
solenoid leaks and measure between
the wiring connector of the relative
solenoid and the appliance housing
if there is any current leakage
(fig. 6 and tab. 1).
Is there any leakage?
YES
Replace the wiring and restart the
diagnostic cycle to check for further
Fig. 6
Tab. 1
NO
YES
NO
alarms.
Ω
Ω
Ω
Main circuit
board
95/121
Replace the main circuit
board and restart the
diagnostic cycle to check for
further alarms.
Replace the main circuit
board and restart the
diagnostic cycle to check for
further alarms.
If there are traces of burning on the
circuit board, refer to pages
EC1
119-120
599 70 99-00
Table of Contents