Cpu Electronic Removal (Cva 610) - Miele CVA 610 Technical Information

Coffee systems
Table of Contents
CVA 610/CVA 615 Coffee Systems
Figure 5-2: Interference Suppression Filter Mounting Location
5.3

CPU Electronic Removal (CVA 610)

1. Remove the lid; see Section 5.1.
2. Disconnect the door switch connections.
3. Disconnect all connections from the CPU electronic.
4. Remove the T10 screws securing the electronic at the corners.
5. Remove the CPU electronic from the appliance.
5.4
Power Electronic Removal (CVA 615)
1. Remove the lid; see Section 5.1.
2. Disconnect the door switch connections.
3. Disconnect all connections from the power electronic.
4. Remove the T10 screws (up to 9) securing the power electronic.
5. Remove the power electronic from the appliance.
5.5
Control Electronic Removal (CVA 615)
1. Remove the lid; see Section 5.1.
2. Disconnect all connections from the control electronic.
3. Remove the two T10 screws securing the electronic at the corners.
4. Remove the control electronic from the appliance.
5.6
Rear Panel Removal
1. Remove the lid; see Section 5.1.
2. Remove the interference suppression filter; see Section 5.2.
3. Remove the screws securing the rear panel.
4. Disconnect the ground connection from the rear panel.