Parameter
12.001
Threshold Detector 1 Output
12.002
Threshold Detector 2 Output
12.003
Threshold Detector 1 Source
12.004
Threshold Detector 1 Level
12.005
Threshold Detector 1 Hysteresis
12.006
Threshold Detector 1 Output Invert
12.007
Threshold Detector 1 Destination
12.008
Variable Selector 1 Source 1
12.009
Variable Selector 1 Source 2
12.010
Variable Selector 1 Mode
12.011
Variable Selector 1 Destination
12.012
Variable Selector 1 Output
12.013
Variable Selector 1 Source 1 Scaling
12.014
Variable Selector 1 Source 2 Scaling
12.015
Variable Selector 1 Control
12.016
Variable Selector 1 Enable
12.023
Threshold Detector 2 Source
12.024
Threshold Detector 2 Level
12.025
Threshold Detector 2 Hysteresis
12.026
Threshold Detector 2 Output Invert
12.027
Threshold Detector 2 Destination
12.028
Variable Selector 2 Source 1
12.029
Variable Selector 2 Source 2
12.030
Variable Selector 2 Mode
12.031
Variable Selector 2 Destination
12.032
Variable Selector 2 Output
12.033
Variable Selector 2 Source 1 Scaling
12.034
Variable Selector 2 Source 2 Scaling
12.035
Variable Selector 2 Control
12.036
Variable Selector 2 Enable
12.040
BC Brake Release
12.041
BC Enable
12.042
BC Upper Current Threshold
12.043
BC Lower Current Threshold
12.044
BC Brake Release Frequency
12.045
BC Brake Apply Frequency
12.046
BC Brake Delay
12.047
BC Post-brake Release Delay
12.050
BC Initial Direction
12.051
BC Brake Apply Through Zero Threshold
RW
Read / Write
RO
Read only
ND
No default value
NC
Not copied
IP
IP address
Mac
Mac address
126
Electrical
Getting
Basic
installation
started
parameters
the motor
Range ( )
OL
Off (0) or On (1)
Off (0) or On (1)
0.000 to 30.999
0.00 to 100.00 %
0.00 to 25.00 %
Off (0) or On (1)
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Input 1 (0), Input 2 (1), Add (2), Subtract (3),
Multiply (4), Divide (5), Time Const (6), Ramp (7),
Modulus (8), Powers (9)
0.000 to 30.999
±100.00 %
±4.000
±4.000
0.00 to 100.00
Off (0) or On (1)
0.000 to 30.999
0.00 to 100.00 %
0.00 to 25.00 %
Off (0) or On (1)
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Input 1 (0), Input 2 (1), Add (2), Subtract (3),
Multiply (4), Divide (5), Time Const (6), Ramp (7),
Modulus (8), Powers (9)
0.000 to 30.999
±100.00 %
±4.000
±4.000
0.00 to 100.00
Off (0) or On (1)
Off (0) or On (1)
Disable (0), Relay (1), Digital IO (2), User (3)
0 to 200 %
0 to 200 %
0.00 to 20.00 Hz
0.00 to 20.00 Hz
0.0 to 25.0 s
0.0 to 25.0 s
Ref (0), Forward (1), Reverse (2)
0.00 to 25.00 Hz
Num
Number parameter
Bit
Bit parameter
PT
Protected parameter
RA
Rating dependent
Date
Date parameter
Time
Time parameter
Running
NV Media Card
Optimization
Operation
RFC-A
OL
Txt
Text string
US
User save
SMP
Slot,menu,parameter
Onboard
Advanced
Diagnostics
PLC
parameters
Default ( )
RFC-A
RO
Bit
RO
Bit
0.000
RW
Num
0.00 %
RW
Num
0.00 %
RW
Num
Off (0)
RW
Bit
0.000
RW
Num
0.000
RW
Num
0.000
RW
Num
Input 1 (0)
RW
Txt
0.000
RW
Num
RO
Num ND NC
1.000
RW
Num
1.000
RW
Num
0.00
RW
Num
On (1)
RW
Bit
0.000
RW
Num
0.00 %
RW
Num
0.00 %
RW
Num
Off (0)
RW
Bit
0.000
RW
Num
0.000
RW
Num
0.000
RW
Num
Input 1 (0)
RW
Txt
0.000
RW
Num
RO
Num ND NC
1.000
RW
Num
1.000
RW
Num
0.00
RW
Num
On (1)
RW
Bit
RO
Bit
Disable (0)
RW
Txt
50 %
RW
Num
10 %
RW
Num
1.00 Hz
RW
Num
2.00 Hz
RW
Num
1.0 s
RW
Num
1.0 s
RW
Num
Ref (0)
RW
Txt
1.00 Hz
RW
Num
Bin
Binary parameter
PS
Power-down save
DE
Chr
Character parameter
Ver
Unidrive M400 Control User Guide
Issue Number: 1
UL
information
Type
ND NC
PT
ND NC
PT
PT
US
US
US
US
DE
PT
US
PT
US
PT
US
US
DE
PT
US
PT
US
US
US
US
PT
US
US
US
US
DE
PT
US
PT
US
PT
US
US
DE
PT
US
PT
US
US
US
US
ND NC
PT
US
US
US
US
US
US
US
US
US
FI
Filtered
Destination