Preface Preface Thank you for using EV1000 Series variable speed drive made by Emerson Network Power Co., Ltd. EV1000 Series satisfies high performance requirements by using a unique control method to achieve high torque, high accuracy and wide speed-adjusting range. Its anti-tripping function and capabilities of adapting to severe power network, temperature, humidity and dusty environment exceed those of similar product made by other companies, which improves the product’s reliability noticeably;...
·Keep the drive away from combustible materials. · When using optional parts, it is recommended to use those provided by Emerson Network ·Keep the drive away from explosive gas. Power, to secure safety. ·Only qualified personnel shall wire the drive.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 1 Safety Information damaged. Lubrication of mechanical devices ·Cable lugs must be connected to main Over time, the lubricants in mechanical devices, terminals firmly. such as gear box, geared motor, etc. when ·Don’s apply supply voltage (AC 110V or running at low speed, will deteriorate.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 1 Safety Information or damage to components may occur as shown in Derating due to Altitude Fig.1-1. Derating must be considered when the drive is installed at high altitude, greater than 1000m. EV1000 This is because the cooling effect of the Drive is Drive less effective in the thin air.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 2 Specifications and Optional Parts Chapter 2 Specifications and Optional Parts 2.1 Specifications Table 2-1 EV1000 Specifications Item Description EV1000-4Txxxxx: 380V~440V; 50Hz/60Hz Rated voltage & frequency EV1000-2Sxxxxx: 200V~240V; 50Hz/60Hz Input Continuous fluctuation rate: ≤±10%, Permissible fluctuation range short time fluctuation rate: ≤–15%~+10%;...
Page 10
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 2 Specifications and Optional Parts Item Description V/F curve is optimized automatically according to the load condition Auto-energy saving operation to perform energy-saving operation. Auto voltage regulation (AVR) Constant output voltage even if electric network voltage fluctuates Operating current is limited automatically to avoid frequent tripping Auto current limiting of the drive.
Max. Usage Torque continuous rate Model Specs work time (%) (%) (s) EV1000-2S0004G 200Ω/100W Attention: the panel is EV1000-2S0007G 150Ω/200W for status display only. EV1000-2S0015G 100Ω/400W EV1000-2S0022G 70Ω/500W Fig. 2-5 TDP-LED03 EV1000-4T0007G 300Ω/400W TDP-LED03 indicators definitions: EV1000-4T0015G 300Ω/400W Mark Color of LED MEANING EV1000-4T0022G 200Ω/500W...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 2 Specifications and Optional Parts one side 2. Cable for the Flush Mount Faceplate Model: FRC21W1 (3.0M) FRC21W2 (30M) For connecting the flush mount faceplate and the drive. 3. Profibus Adapter Model: TDS-PA01 Able to connect EV1000 drive to PROFIBUS network via the TDS-PA01.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Chapter 3 Installation and Wiring 3.1 Installation Please mount the drive vertically indoors, with good ventilative conditions. When selecting mounting environment, the DRIVEⅡ DRIVEⅠ Electric cabinet followings should be taken into account: Ambient temperature should be within the range of -10℃~40 ℃.
Page 16
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring shielded and may be disturbed lightly. The cables are a few sensitive devices on site, just install are the main EMI source, if you connect the power line filter beside them is enough. Note that cables according to the manual, the EMI can be the drive and contactor are noise source, and the suppressed effectively.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring ·The shortest distance between areas should be 20cm. ·Earthing bars should be used for decoupling among areas, the cables from different area should be placed in different tubes. ·The filter should be installed at the interfaces between different areas if necessary. ·Bus cable(such as RS485) and signal cable must be shielded.
Page 18
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Table 3-1 Method of Noise Suppression Noise emission paths Actions to reduce the noise If the external equipment shares the same AC supply with the drive, the drive’s noise Install noise filter at the input side of the drive, and use an isolation may be transmitted along its input power transformer or line filter to prevent the noise from disturbing the external equipment.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring The drive and other equipment should use 3.1.3 Using Surge Suppressor leakage current circuit breaker designed for protecting the product against high-order The devices such as relay, contactor and harmonics/surge leakage current. electro-magnetic braking kit, which may generate great noises, should be installed with surge Leakage current between lines...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring is protected. At the same time, leakage current Common mistakes in using power line filter and unexpected trigger are reduced. 1. Too long power cable 3.2 Wiring The filter inside the cabinet should be located near to the input power source.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Attention ·The control terminals of the drive is of ELV (Extra Low Voltage) circuit. Do not touch them once energized; ·If the external device has touchable terminals of SELV (Safety Extra Low Voltage) circuit. Remember to connect isolating protections in between.
Page 22
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring P(+) PB (-) circuit breaker 3-phase Power circuit 380V 50/60Hz Auxiliary Power FWD/STOP REV/STOP Multifuction input 1 0/4~20mA 0/2~10V DC current meter Multifuction input 2 CN16 Multifuction input 3 0/4-20mA current Multifuction input 4 0/4~20mA signal 0/2~10V...
If the control circuit uses multi-strand cable, the single-core cable section area can be 0.5mm 3.2.2 Power Terminals Note: The tig htening torque is 14kgf.cm. Protective earth 1. EV1000-2S0004G,EV1000-2S0007G wire should be connected to the heater’s screw marked 。 with The power terminal layout is shown in the figure 2.EV1000-4T0007G,EV1000-4T0015G,...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Table 3-6 Function of Control Terminals Note: Mark Function The tightening torque should be 17kgf.cm. For Relay outputs EV1000-2S0015G, power cable can be connected to any two of R, S, T. Analog I/O, digtial I/O 3.EV1000-4T0037G,EV1000-4T0037P,...
Page 25
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring EV1000 Series General Purpose Variable Speed Drive User Manual...
Page 26
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring 3.CN5 Terminals Wiring The layout of CN5 is shown in the figure below: TA-TB: normally closed; TA-TC: normally open Contact capacity: 250VAC/2A(COSφ=1) ,250VAC/1A(COSφ=0.4) ,30V TA, TB and TC can be defined as multi-functional digital output signals. Please refer to Section 5.8. If there are inductive loads, such as: electro-magnetic relay and contactor, surge snubber circuit, e.g.
Page 27
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Category Terminals Name Function Specification Be able to output analog voltage/current (total 12 kinds of signals). Jumper CN16 can select Analog output voltage or current input mode, Voltage input mode is the default mode. Refer to F7.26 for Output current range: details.
Page 28
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Category Terminals Name Function Specification +10V power Output: +10V, Provide +10V power supply supply Power Setpoint accuracy: ±10% supply GND of +10V reference ground of analog signal and 10V Max. output current: 100mA power supply power supply TA-TB: normally closed;...
Page 29
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring RS485/RS232 Sign-a EV 1000 converter shielded Function Terminal RS485 port cable Enclo- 5V power + 5V ● sure Transmit Receive Ground ● Function terminal Terminal Function - RS485 - RS485 - - RS485 +...
Page 30
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring When using External power supply, remember to +24V disconnect PLC and P24. +3.3V External controller EV1000 3.3V ● current ● 9~30V ● ● X1、X2 . . . X5 ● ● FWD、REV EV1000 3.3V Fig.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring 4. The control cables should be as far away (at least +24V 20cm) as possible from the main circuits and high DC 9~30V voltage cables (including power supply cables, motor cables, relay cables and cables of contactor). The cables should be vertical to each other to reduce the Relay disturbance to minimum.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 3 Installation and Wiring Use conductive plate and dentate pad to clear Other away the paint between the screws and metal drive equipment casing, to ensure good conductivity. PE(G) enclosure enclosure Fig. 3-28 Earthing Diagram 3 Fig.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 4 Operation Procedures Chapter 4 Operation Procedures 4.1 Definitions of Terms How to set Frequency The output frequency is decided after calculating In the follow-up sections, you may encounter the the values from one or more of the 7 frequency terms describing the control, running and status setting channels, which involves the concept of of drive many times.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 4 Operation Procedures loop operation>PLC>MS>Simple operation” F4.00 setting is a non-zero value. The drive will according to the priority. run according to the preset mode, see F4 function group. It can be disabled by multi-function Jog: terminal (function No.21).
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 4 Operation Procedures 4.2.2 Keypad Function Explanation There are 7 keys on the LED keypad display unit, refer the function of each key in Table 4-1. Table 4-1 Key’s Function Name Function Program key To shift between stop state and program state FUNC/DATA Function/data key To shift between function code menus, confirm modification...
Page 36
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 4 Operation Procedures 2.Menu Structure and Parameter When setting parameter through LED keypad display unit, function group is listed in menu level 1, parameter in menu level 2, and settings of parameters in menu level 3. See Appendix 1. 3.Examples of Parameter Setting The setting of parameter is presented in decimal (DEC) and hexadecimal (HEX) format.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 4 Operation Procedures Refer to the figure below. Reference Frequency is decided by the BIT2 of the one’s place of F8.01. If BIT2=1, it means the parameter will be displayed. For those parameters you don’t want to display, you may set the corresponding bit at Zero.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 4 Operation Procedures 4.2.6 How to Lock/Unlock Keypad Lock Keypad: Set the hundred’s place of F9.07 at non-zero value. Press FUNC/DATA key and PRG key at the same time, thus the keypad is locked. FUNC DATA 50.00 -F9- F9.00...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Chapter 5 Parameters Note: Note: The contents in the“ 【】 ”are factory default. For method 3, 4 and 5, the frequency calculation curve is given in F1.00~F1.11, please refer to 5.2. 5.1 Basic Parameters (F0) F0.01 Digital Frequency Control Range: 00~11 【00】...
Page 40
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters the drive. output voltage 1: Terminal control: Input operating commands via terminals Use terminals FWD, REV, to start and stop the drive. 2: Serial port control: Input operating commands output frequency via serial port Use serial port to start and stop the drive.
Page 41
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Note: Note: 1. Wrong parameter setting can cause overheating of It is possible for the actual output frequency to the motor or triggers the over-current protection of the fluctuate within ±2.5Hz in the bus-voltage control drive.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters F1.08~F1.11 respectively. Both of them can work ③ 1kHz input for reference frequency 50Hz, as positive or negative logic, as shown in Fig. 5-8. 20kHz input for reference frequency 5Hz; To meet the above requirement, you should set: Reference freq.
Page 44
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters If the brake time at startup is set at 0.0s, no brake Note: process. 1. Start mode 1 applies to small-inertia motor when the drive stops, the motor is still rotating. For Output large-inertia load, do not restart until the motor stops. frequency 2.
Page 45
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters reduce output frequency to zero and stop within Frequency preset deceleration time. 1. Coast to stop When the drive receives Stop command, it will stop outputting frequency and stop gradually relying on load inertia. 2: Deceleration+DC braking Time When the drive receives Stop command, it will...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters rotation changes from FWD to REV or REV to Output Freq. FWD, see Fig. 5-16 as t Output Initial Freq.of braking frequency Output Waiting time volt Braking Time Energy (RMS value) Braking time Fig. 5-16 Transition time from FWD to REV Operating command F3.02~F3.04...
Page 47
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Table 5-1 Relation of Model and Carrier Freq. Range: 0.0~300.0% F3.07 Slip compensation gain Default 【100.0%】 Model (kHz) Range: 0.0~250.0% F3.08 Slip compensation limit EV1000-2S0007G 【200.0%】 Others Range: 0.1~25.0s F3.09 Compensation time Table 5-2 Carrier Freq. and Performance 【2.0s】...
Page 48
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters between jog (F3.14), f is jog frequency (F3.13). different combinations of control terminals, refer to F7.00~F7.07 for the definitions of terminals Actual jog Acc and Dec time are calculated by the used to select Acc/Dec time. formula below: F3.13×F3.15 Note:...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters F3.30~F3.35 are used to skip the mechanical Y2 of open collector output or relay output. See resonant frequency of load. F7.10~F7.12. The drive’s preset frequency can skip some Range: 0000~1123 frequency as shown in Fig. 5-19. Three skip F4.00 Simple PLC mode 【0000】...
Page 50
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Stopping signal Output freq.Hz Time Operating Remnant time of Stage 1 time of stage 2 stage 2 : Acc time of stage 1 : Acc time of stage 2 : Acc time of stage 3 : Dec time of stage 2 command : Freq.
Page 51
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters time will be saved when poweroff, and the drive Ten One will start according to the setting of ten’s place of Frequency setting F4.00 after powerup. 0: Preset frequency i 1: Determined by F0.00 Thousand’s place: Selection of time unit 2: Preset close-loop reference i 3: Determined by F5.01...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters 5.6 Close-loop Control (F5) controlled by terminal FWD. The above system can also use a TG (speed Usually, the close loop control can be divided into measuring generator) as speed close speed-loop two types: analog close loop and pulse close loop control according to feedback.
Page 53
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters ε KP × (F5.12) ε Error limit Regulation Reference Reference Output (F5.16) (F5.15) regulation ε Ki × ∑ (F5.08 and F5.10) (F5.13) Feedback regulation Feedback (F5.09 F5.11) Fig. 5-30 PI Working Mechanism Where: increased, this control characteristic is called negative response.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters F5.23 MS close-loop Range: 0.0 ~ 10.00V 【 0.00V 】 Output Freq. setting 4 Preset freq. F5.24 MS close-loop Range: 0.0 ~ 10.00V 【 0.00V 】 setting 5 F5.25 MS close-loop Range: 0.0 ~ 10.00V 【 0.00V 】 setting 6 hold time F5.26 MS close-loop...
Page 57
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Freq. (Hz) Traverse amplitude Aw=Fset*F6.04 Upper limit of freq. F + Aw Central Freq. Fset - Aw Lower limit of freq. F Step freq.=AW*F6.05 Preset freq. Rising Waiting time Accelerate Decelerate F6.03 time=F6.06*F6.07 according according to Acc time Traverse...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters corresponding parameter is set at 33, the drive F0.05×F6.04 will enter traverse mode. If the terminal is Note: disabled, the drive will exit traverse mode and The traverse frequency is limited by upper and lower stay at preset frequency F6.02.
Page 59
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters The multi-function terminals can realize various Setting Functions functions. You may assign functions to them by Terminal control mode is forcibly enabled setting parameters F7.00~F7.04. Please refer to Control mode 1 Table 5-3. Take X1~X3 for example in the Control mode 2 following description.
Page 60
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Table 5-5 Acc/Dec Time Defined by Terminal Freq. State Commination MS freq. 4 Terminal 2 Terminal 1 Acc/Dec time selection MS freq. 5 Acc time 1/Dec time 1 MS freq. 6 Acc time 2/Dec time 2 MS freq.
Page 61
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters terminal for reverse jog operation command. Jog Note: frequency, jog interval and jog Acc/Dec time are Different from function 6~7, the external interrupt defined in F3.13~F3.16. signal will not cause alarm, and the drive will resume previous running once the signal removed.
Page 62
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Table 5-6 Frequency Setting Mode Selection X1~X5) Mode Table 5-8 MS Close-loop Setting Selection MS close-loop reference None By F5.01 Digital setting1 MS Close-loop setting 1 Digital setting 2 MS Close-loop setting 2 Digital setting 3 MS Close-loop setting 3 VCI analog setting MS Close-loop setting 4...
Page 63
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters zero. 48: Speed measuring input SM2 This function is effective only to multi-function 40: Clear the setting of auxiliary reference input terminals X4 and X5. See section 3.2.3 for frequency input characteristics. The speed control accuracy This function is valid for auxiliary reference is ±0.1%.
Page 64
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Where: Refer to section 3.3.2 for the output characteristics of Y1, Y2 and the relay’s output SB1:Stop button terminal. Table 5-9 shows the functions of the SB2: Run forward button above 3 terminals. Note that one function can be SB3: Run reverse button selected repeatedly.
Page 65
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters current is bigger than the value defined by FL.05 Setting Function Range and the overload time is longer than the time Freq. before slip 0 ~ Max. output freq. defined by FL.06. This function is usually used for compensation overload pre-alarm.
Page 66
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters 15: drive ready (RDY) Output The RDY signal is output when the drive has no fault, its DC bus voltage is normal, the Start detecting range Preset Prohibit function is disabled. It is ready to start. freq.
Page 67
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters 10V (20mA). Please refer to Appendix 2. F7.27 AO2 output selection Range: 0 ~ 12 【 3 】 Suppose you want: F7.28 Reserved AO1 outputs 4~20mA, which means the bus AO1 and AO2 are analog output terminals. voltage is 0~800V.
Page 68
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters It defines the max. pulse frequency from terminal Thou. Hun. Ten One's place Y2. Refer to F7.12. BIT0 : positive/negative logic of X1 BIT1: positive/negative logic of X2 F7.33 Preset counting value Range: F7.34 ~ 9999 【 0 】 BIT2: positive/negative logic of X3 BIT3 : positive/negative logic of X4 F7.34 Specified counting...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Binary Thousand Hundred Ten One (LED display) BIT3 BIT2 BIT1 BIT0 BIT0: output freq. ( before compensation) BIT1: output freq. (after comensation) BIT2: set freq. BIT3: output current (A) BIT0 :actual speed (rpm) BIT1:set speed (rpm) BIT2:actual line speed (m/s) BIT3 :set line speed (m/s)
Page 70
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters The displayed terminal information includes Thousand Hundred Ten One status of terminal X1~X5, bi-direction BIT0: reference freq. open-collector output terminals Y1 and Y2, and BIT1: external counting value relay output terminal TC. The status of terminals BIT2: actual speed (rpm) are indicated by the “On”...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters For example: 【 100.0 %】 In order to realize remote and local control, it It is used to calibrate the error between preset or requires that: feedback parameters and the actual ones. It has ①Control modes selection: The control modes no effect on close-loop PI regulation.
Page 72
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters factor main freq. ∑ F9.05, F9.06 3-phase preset freq. EV1000 power supply common operation freq. (F0.00=0~5) MS freq. ( F3.23~F3.29 ) auxiliary freq. simple PLC freq. ( F4.00~F4.14 ) no auxiliary freq. (F9.01=0) close-loop freq. (F5.00~F5.26) digital setting (...
Page 73
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters serial port to change auxiliary frequency. It is valid when F9.01=1~3. See Fig. 5-62. If VCI-5 or CCI-5 is selected, take 5V input as the Thou. Hun. Ten One point corresponding to zero frequency, 0~5V input Save corresponds to negative output, 5~10V input 0: Save ref.
Page 74
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters 0: disabled and the drive will stop in specified manner. But in terminal or serial port control mode, pressing this No additional summing operation to the sum of key will trigger E015 alarm and the drive will coast main freq.
Page 75
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters frequency hysteresis control. Take analog CCI for example, see Fig.5-66: Load Conveyer Startup process: Motor When the Run command is given out, only after CCI current arrives at I and the corresponding Drive frequency reaches fb, does the drive start and Fig.
Page 76
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters F9.18 Shaft Range: 0.01 ~ 100.00cm circumference 【 10.00cm 】 F9.19 Pulse per Range: 1 ~ 9999 【1】 revolution The above parameters are used for length control, i.e. the drive will stop when arriving certain length. The counting pulse is input from X4 or X5 which is defined as function No.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters recommended to set F9.21 according to load and 5.12 Communication (FF) its inertia. FF.00 Communication Range: 0000 ~ 1127H 【 0005 】 F9.22 Conditions of restart Range: 0, 1 【 0 】 config after power failure F9.23 Restart delay after Range: 0.0~10.0s 【0.5 s 】...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Note: FH.06 Rotor Range: 0.0 ~ 50.00 %【 Depending resistance % R2 ”127” is the broadcasting address. When it is set so, on model 】 the slave can receive and execute the command by FH.07 Mutual host, but will not answer back.
Page 79
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters If motor’s parameters are available, please set When starting a rotating auto-tuning, at first, the FH.04 ~FH.07 to the values calculated according motor is in standstill status, and the stator’s to the above formula. resistance (%R1), rotor’s resistance (%R2) and the leakage inductance (%X1) will be measured, If the drive performs auto-tuning of motor’s...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Time 100% FH.10 Motor stabilization Range: 0 ~ 255 fator 【 Depending on model 】 Motor overload FH.10 is used to suppress the oscillation caused protective coefficient by the drive and the motor. If the drive’s output current changes constantly at fixed load, the 1min oscillation can be reduced by adjusting FH.10.
Page 81
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters reducing its output frequency. When the detected Thou. Hun. Ten bus voltage is lower than the point, the Overload detection mode deceleration will continue. Please refer to in Fig. 0: Detect all the time 1: Detect in case of constant speed 5-71.
Page 82
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters FL.09=0: disabled; Output current Overload threshold FL.09=1: auto current limiting is effective during acceleration or deceleration but ineffective at alarm delay alarm delay constant speed, no silencing function; Time Alarm FL.09=2: effective all the time, no silencing Effective period function;...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Thou. Hun. Ten One FL.18 Output current at Range:0 ~ 999.9A 【 0.0A 】 the last fault Action for communication fault 0: Alarm and coast to stop 1: No alarm, continue operation FL.19 Freq. at the last Range:0.00~650.00Hz 2: No alarm, stop fault...
Page 84
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 5 Parameters Press PRG, input the old password, and then select FP.00 (at this time FP.00=0000), input new password and press FUNC/DATA to confirm. The password will become effective if not pressing any key within 5 minutes. Note:...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 6 Troubleshooting Chapter 6 Troubleshooting All the possible faults of EV1000 have been given in Table 6-1. Fault code range is E001~E024. You can user can check the faults according to the following table and record detailed fault phenomena before seeking service.
Page 86
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 6 Troubleshooting Fault Fault Possible reasons Actions code descriptions Abnormal AC supply voltage Check the AC supply voltage Over voltage in Too short Acc/Dec time Prolong the Acc/Dec time constant-speed E006 operating Abnormal change of input voltage Install input reactor process Too high load inertia...
Page 87
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 6 Troubleshooting Fault Fault Possible reasons Actions code descriptions Press STOP key when operating at Check the present operating mode non-keypad mode Press STOP when the drive is in stall Set the operating parameters correctly Emergency stop status E015 or external...
Page 88
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 6 Troubleshooting Table 6-1 Operation Related Faults and Counteractions Phenomena Conditions Possible reasons of fault Actions to take In stop or operating state, keep pressing FUNC/DATA key, when pressing ▼ key Keypad locked three times. No response Part of the keys or all the Power off the drive and then power on again.
Page 89
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 6 Troubleshooting Phenomena Conditions Possible reasons of fault Actions to take Alarm occurs Find out the reason and reset. Single cycle of PLC finishes Check PLC configuration Preset length arrives Clear the actual length value or set F9.14 at Interruption of the The drive stops communication between the...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 7 Maintenance Chapter 7 Maintenance Many factors such as ambient temperature, humidity, dust, vibration, internal component aging, wear and tear will give rise to the occurrence of potential faults. Therefore, it is necessary to conduct routine maintenance to the drives.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 7 Maintenance Refer to the table below. General Inspection: Part Life 1. Whether screws of control terminals are loose. 30 ~ 40 thousand hours If so, tighten them with a screwdriver; 2. Whether the main circuit terminals are properly Electrolytic capacitor 40 ~...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Chapter 7 Maintenance 2. Long-term storage will cause the deterioration 3. Even within 18 months, maintenance would be of electrolytic capacitors. Therefore, the drive charged under the following conditions: must be switched on for a test within 2 years, for ①...
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Appendix 1 Parameter Set EV1000 Series drive’s parameters are organized the user.) in groups. Each group has several parameters The drive provides passwords to protect the that are identified by “Group No.+ Parameter SN.”. parameters against unauthorized modifications.
Page 94
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Table 1 Parameter Set Group 0: Basic Operating Parameters Para. Name Range Min unit Default Modification 0: digital setting 1, set by ▲ or ▼ key. 1: digital setting 2, set by terminal UP/DN 2: digital setting 3, set through serial port Frequency 3: VCI analog setting ( VCI-GND)
Page 95
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 0: Basic Operating Parameters Para. Name Range Min unit Default Modification F0.08 Reserved F0.09 Torque boost 0: (auto) 0.1 %~ 30.0 % 0.1 % 0.0 % ○ F0.10 Acc time 1 0.1 ~ 3600 6.0s ○...
Page 96
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 1: Reference Frequency Para. Name Range Unit Default Modification One’s place of F1.00: VCI curve selection 0: curve 1 1: curve 2 Ten’s place of F1.00: CCI curve selection F1.00 Freq. Curve selection 0: curve 1 ○...
Page 97
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 1: Reference Frequency Para. Name Range Unit Default Modification Ratio of Min. input of F1.08 0.0 %~ F1.10 0.1 % 0.0 % ○ curve 2 to F1.03 Frequency F1.09 corresponds to min. 0.00 ~...
Page 98
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 2: Start/Brake Parameters Para. Name Range Unit Default Modification G type: 0.0~150.0 % of drive’s rated current (max. among phases) DC brake current at 0.1 % 0.0 % F2.03 ○ startup P type: 0.0~130.0 %...
Page 99
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 2: Start/Brake Parameters Para. Name Range Unit Default Modification G type: 0~150% of drive’s rated current (max. among the 3 phases), F2.11 DC brake current 0.1 % 0.0 % ○ P type: 0~130% of drive’s rated current (max. current among the 3 phases).
Page 100
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 3: Auxiliary Operating Parameters Para. Name Range Unit Default Modification F3.08 Slip compensation limt 0.0 %~ 250.0 % 0.1 % 200.0 % ○ F3.09 Compensation time 0.1 ~ 25.0s 0.1s 2.0s × 0.7k ~...
Page 101
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 3: Auxiliary Operating Parameters Para. Name Range Unit Default Modification F3.27 MS freq. 5 40.00Hz 0.01Hz F3.28 MS freq. 6 45.00Hz F0.13~ F0.12 F3.29 MS freq. 7 50.00Hz F3.30 Skip freq. 1 0.00 ~...
Page 102
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.00, PLC running mode selection 0: Disabled 1: stop after a single cycle 2: Maintain value of the last stage after 1 cycle 3: continuous cycle Ten’s place of F4.00: Restart mode after PLC interruption 0: start from the first stage...
Page 103
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.01: 0: select MS frequency 1, (F3.23) 1: decided by F0.00 2: MS close loop setting 1 (F5.20) 3: decided by F5.01 Ten’s place of F4.01: running direction 0: forward F4.01 Stage 1 setting...
Page 104
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.03: 0: select MS frequency 2, (F3.24) 1: decided by F0.00 2: MS close loop setting 2 (F5.21) 3: decided by F5.01 Ten’s place of F4.03: running direction 0: forward F4.03 Stage 2 setting...
Page 105
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.05: 0: select MS frequency 3, (F3.25) 1: decided by F0.00 2: MS close loop setting 3 (F5.22) 3: decided by F5.01 Ten’s place of F4.05: running direction 0: forward F4.05 Stage 3 setting...
Page 106
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.07: 0: select MS frequency 4, (F3.26) 1: decided by F0.00 2: MS close loop setting 4 (F5.23) 3: decided by F5.01 Ten’s place of F4.07: running direction 0: forward F4.07 Stage 4 setting...
Page 107
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.09: 0: select MS frequency 5, (F3.27) 1: decided by F0.00 2: MS close loop setting 5 (F5.24) 3: decided by F5.01 Ten’s place of F4.09: running direction 0: forward F4.09 Stage 5 setting...
Page 108
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.11: 0: select MS frequency 6, (F3.28) 1: decided by F0.00 2: MS close loop setting 6 (F5.25) 3: decided by F5.01 Ten’s place of F4.11: running direction 0: forward F4.11 Stage 6 setting...
Page 109
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 4: PLC Parameters Para. Name Range Unit Default Modification One’s place of F4.13: 0: select MS frequency 7, (F3.29) 1: decided by F0.00 2: MS close loop setting 7 (F5.26) 3: decided by F5.01 Ten’s place of F4.13: running direction 0: forward F4.13 Stage 7 setting...
Page 110
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set F5: Close-loop Control Para. Name Range Unit Default Modification 0: disabled F5.00 Close loop control × 1: enabled 0: digital setting Take the value of F5.05 if F5.02 = 1~5; Take the value of F5.06, if F5.02 = 6. 1: VCI (0 ~...
Page 111
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set F5: Close-loop Control Para. Name Range Unit Default Modification 1 ~ 9999 F5.07 Pulse number per 1024 ○ revolution of encoder 0.0% ~ (F5.10) (pecentage of the min. input to F5.08 Min. input 0.1 %...
Page 112
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set F5: Close-loop Control Para. Name Range Unit Default Modification 0.0 ~ 3600s Preset frequency hold F5.19 0.1s 0.0s × time F5.20 MS close-loop setting 1 0.00V ~ 10.00V 0.01V 0.00V ○ F5.21 MS close-loop setting 2 0.00V ~ 10.00V 0.01V 0.00V ○...
Page 113
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 6: Traverse Operating Parameter Para. Name Range Unit Default Modification F6.00 Traverse function selection 0: disabled × 1: enabled One’s place of F6.01: transfer mode 0: auto (according to F6.03) 1: terminal configuration (manually) en’s place of F6.01: amplitude control 0: varied amplitude 1: fixed amplitude...
Page 114
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification Function of multi-function 0: No function terminal X1 1: MS frequency 1 F7.00 2: MS frequency 2 3: MS frequency 3 4: Acc/Dec time 1 F7.01 Function of multi-function terminal X2 5: Acc/Dec time...
Page 115
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification 14: PLC operation pause 15: Acc/Dec prohibit 16: 3-wire operation control 17: External interrupt signal normally-open input 18: External interrupt signal normally-close input 19: DC injection braking command (DB) 20: Disable close-loop 21: Disable PLC...
Page 116
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification 36: Reserved 37: Drive operation prohibiting 38: Reserved 39: Clear length 40: Clear auxiliary reference frequency 41: Reset PLC Stop status 42: Clear counter’s record ×...
Page 117
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification 0: Drive running signal (RUN) 1: Frequency arrival signal (FAR) 2: Frequency detection threshold (FDT1) Open collector output 3: Frequency detection threshold (FDT2) F7.10 ×...
Page 118
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification 14: Preset length arrival 15: Drive ready (RDY) 16: Drive fails 17: Extended function 1 of host 18: Upper and lower limits of traverse frequency 19: Preset operation time out 20: Freq.
Page 119
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification F7.13 Freq. arrival detection 0.01Hz 2.50Hz ○ 0.00 ~ 650.0Hz range (FAR) F7.14 FDT1 level 0.00 ~ 650.0Hz 0.01Hz 50.00Hz ○ F7.15 FDT1 lag 0.00 ~...
Page 120
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification F7.27 AO2 output function ○ F7.28 Reserved One’s place of F7.29: AO1 bias 0: 0 ~ 10V or 0 ~ 20mA 1: 2 ~ 10V or 4 ~ 20mA F7.29 Analog output range ○...
Page 121
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 7: Multi-function Terminals Para. Name Range Unit Default Modification 0.0 ~ 200.0 % 0.1 % 100.0 % F7.30 AO1 output gain ○ F7.31 AO2 output gain 0.0 ~ 200.0 % 0.1 % 100.0 %...
Page 122
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 8: Display Control Parameters Para. Name Range Unit Default Modification 0~999.9km F8.00 Accumulated length 0.1km ○ Note: This parameter can be viewed or cleared only. Binary code implication: 0: not displayed 1: displayed One’s place BIT0: output freq.
Page 123
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 8: Display Control Parameters Para. Name Range Unit Default Modification Binary code implication: 0: not displayed 1: displayed One’s place BIT0: output voltage (V) BIT1: bus voltage BIT2: VCI (V) BIT3: CCI ( V) LED displayed F8.02 Hundred’s place...
Page 124
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 8: Display Control Parameters Para. Name Range Unit Default Modification Binary code implication: 0: not displayed 1: displayed One’s place BIT0: reference frequency ( Hz) BIT1: external counter value (no unit) BIT2: rotating speed (r/min) BIT3: preset rotating speed ( r/min) Ten’s place: BIT0: actual line speed ( m/s)
Page 125
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 8: Display Control Parameters Para. Name Range Unit Default Modification 0.1 ~ 999.9 % Mechanical speed=measured speed×F8.04 ( PG) Mechanical speed =120×actual freq.÷FH.00×F8.04 Rotating speed display (non-PG) F8.04 0.1 % 100.0 % ○...
Page 126
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 9: Enhanced Function Para. Name Range Unit Default Modification One’s place: in keypad control mode 0: no binding 1: digital setting 1 (adjust by ▲ and ▼ key) 2: digital setting 2 (adjust by terminal UP/DN) 3: digital setting 3 (adjust by serial port ) 4: VCI analog setting Operating command...
Page 127
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 9: Enhanced Function Para. Name Range Unit Default Modification 0: No auxiliary freq. 1: Digital setting 1, adjust by ▲ and ▼ 2: Digital setting 2, adjust by UP/DN 3: Digital setting 3, set by serial port 4: VCI analog setting 5: CCI analog setting 6: terminal pulse setting...
Page 128
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 9: Enhanced Function Para. Name Range Unit Default Modification One’s place: save auxiliary freq. at power-off 0: save 1: not save Ten’s place: 0: maintain the aux. Freq. after stop Digital auxiliary ref. F9.04 ○...
Page 129
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 9: Enhanced Function Para. Name Range Unit Default Modification One’s place: STOP/RESET key function 0: valid only in keypad control mode 1: valid in keypad, terminal, serial port mode, to stop the drive in specified manner 2: to stop the drive in keypad control mode in specified manner, for other control mode, display E015 fault and coast to stop...
Page 130
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group 9: Enhanced Function Para. Name Range Unit Default Modification 0.000 ~ 65.535 ( km) (save after power off) F9.15 Actual length 0.001 0.000 ○ ( km) ( km) F9.16 Length factor 0.001 ~ 30.000 0.001 1.000 ○...
Page 131
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FF: Communication Parameters Para. Name Range Unit Default Modification One’s place: baud rate 0: 300BPS 1: 600BPS 2: 1200BPS 3: 2400BPS 4: 4800BPS 5: 9600BPS 6: 19200BPS 7: 38400BPS Ten’s place: data format FF.00 Communication config 0005 ×...
Page 132
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FH: Motor’s Parameters Para. Name Range Unit Default Modification 2 ~ 14 FH.00 Motor’s poles × FH.01 Rated power 0.4 ~ 999.9kW 0.1kW Depending on model × FH.02 Rated current 0.1 ~ 999.9A 0.1A Depending on model ×...
Page 133
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FL: Protection Parameters Para. Name Range Unit Default Modification 0: disabled Motor 1:Common motor (with low speed compensation) FL.00 overload × 2: Variable frequency motor (without low speed protection compensation) Motor 20.0 ~ 110.0 % overload 0.1 %...
Page 134
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FL: Protection Parameters Para. Name Range Unit Default Modification G type: 20.0 %~ 180.0 % Overload 130.0 % 0.1 % FL.05 detection × P type: 20.0 %~ 130.0 % 120.0 % threshold Overload FL.06 0.0 ~...
Page 135
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FL: Protection Parameters Para. Name Range Unit Default Modification One’s place: action if communication fault 0: alarm and coast to stop 1: not alarm and continue the operation 2: not alarm and stop in specified manner (only for serial port control mode) Protective FL.12...
Page 136
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FL: Protection Parameters Para. Name Range Unit Default Modification 0: not fault Fault type of 1: overcurrent during acceleration (E001) FL.14 the first time 2: overcurrent during deceleration (E002) 3: overcurrent during constant-speed running (E003) 4: overvoltage during acceleration (E004) Fault type of 5: overvoltage during deceleration (E005)
Page 137
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set Group FL: Protection Parameters Para. Name Range Unit Default Modification Bus voltage 0 ~ 999V FL.17 at the last fault Output 0.0 ~ 999.9A FL.18 current at the 0.1A 0.0A last fault Freq. at the 0.00Hz ~...
Page 138
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 1 Parameter Set FP: Protection of Parameters Para. Name Range Unit Default Modification 0: All parameters are allowed to be changed; 1: No parameters can be changed except the F0.02 Write-in FP.01 ○ and FP.01; protection 2: No parameters can be changed except FP.01.
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Appendix 2 Communication Protocol 1. Networking Mode Host is PLC Host is PC Host is PC RS232 RS232 RS232-RS485 RS232-RS485 adapter adapter RS485 RS485 EV1000 TD1000 TD2000 TD2100 EV1000 single master and single slave single master and multi-slave Fig.
Page 140
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol 3. Protocol Format c o m m a n d fr a m e o f m a s te r c o m m a n d fr a m e o f m a s te r s e n d in g s e q u e n c e d e fin itio n...
Page 141
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Note: Report whether the response code is Table 2 Response Code of Command Code “00” related to the current configuration status of the Meaning slave. Refer to the notes of “command code = 5”. Response Slave Host contol...
Page 142
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Fault Fault 6) Frame Tail Description Description Index Index Hex OD, Single byte. Control power supply Reserved overvoltage Phase loss at Reserved input side Heatsink Reserved overheat Drive overload Motor overload External device PROM fault or damaged...
Page 143
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol 5. Command list of protocols In the following table, frame head 7E, frame tail OD, address and checksum are omitted. The format is ASCII character. Note For those parameters that are constantly modified, such as reference frequency, Acc/Dec time, MS frequency, close loop setting, auxiliary frequency set by serial port, please use command 08 to avoid damaging E PROM.
Page 144
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Host control(C lanuguage, Host Secondary Command Name Data Range character string format, slave Data accuracy Description Command index Index address 01) Read Set speed None ~010100050187\r 1rpm Slave Actual line speed None ~010100060188\r 0.01 m/Min Parameter Set line speed...
Page 145
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Host control(C lanuguage, Host Secondary Command Name Data Range character string format, slave Data accuracy Description Command index Index address 01) Present status None ~0101000D0196\r Frequency after None ~010100140187\r 0.01 Hz compensation Slave power-on None ~010200000183\r None...
Page 146
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Host control(C lanuguage, Host Secondary Command Name Data Range character string format, slave Data accuracy Description Command index Index address 01) Slave power-on, 0Hz~upper forward, with reference ~0102000503E80268\r 0.01 Hz Reference frequency =10.00Hz limit frequency given Slave power-on,...
Page 147
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Host control(C lanuguage, Host Secondary Command Name Data Range character string format, slave Data accuracy Description Command index Index address 01) Slave coast to stop None ~0102000D0197\r None Slave emergency stop None ~0102000E0198\r None 0~65535 Set analog output AO1...
Page 148
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Host control(C lanuguage, Host Secondary Command Name Data Range character string format, slave Data accuracy Description Command index Index address 01) Set analog contorl bit0~4: virtual terminal X1~X5, 0~FFFF ~01020017FFFF02A3\r terminal status BIT8~12, FWD, REV, Y1, Y2, TC Frequency digital None ~010300010185\r...
Page 149
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Host control(C lanuguage, Host Secondary Command Name Data Range character string format, slave Data accuracy Description Command index Index address 01) Read Dec time 1 F0.11 0~8CA0 ~0104000A03E80276\r 0.1s parameter Digital setting F5.05 0~03E8 ~0104006603E80271\r 0.01V...
Page 150
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Table 5 Status Word’s Meaning Meaning Description bit0 Stop/run status Stop bit1 Undervoltage flag Normal undervoltage bit2 ~ 6 Reserved bit7 Count value arrives Invalid Valid bit8 Preset count value arrive flag Invalid Valid bit9 Traverse mode...
Page 151
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Table 6 Reading Slave’s Parameter Values Function Read all slave parameter values except user password and factory password. Meaning Head Address Command Command index Operating data Checksum Tail Host ADDR See the remak None command Number of...
Page 152
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Set parameter (Hex: function group No. + SN) Using this command can set all the parameters of EV1000, except those whose property is “*” and FP.02~FP.04. See Appendix 1. When setting a bit of the parameter, make sure the validity of it, e.g. when setting F9.00, the operating data of the frame is ASCII code, it can be 0000 or 0777 or 0543, but not 0128 or 1000.
Page 153
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Appendix 2 Communication Protocol Note: the usage of command group 7 and 8 is the same. For those parameters that are changed frequently, you may use command group 8 if not required to save to E PROM considering its service life. 6.
Table 9 EV1000 Output Reactor Model reactor, EMI filter. The following models have Drive Input Reactor Model been proved compatible with the drive. If you need them, please contact us. EV1000-2S0004G TDL-2AO01-0004 1. Input/output reactor EV1000-2S0007G TDL-2AO01-0007 AC input reactor: TDL-4AI01-0015, where “0015”...
Page 156
Table 10 EMI Filter Dimentions and Weight Size [mm] Drive Filter model Gross weight [kg] C D E F G H I J K M N P EV1000-2S0004G EV1000-4T0007G DL-5EBT1 M4 6.4 × 9.4 EV1000-4T0015G 184 160 202 42 60 86 18 58 M4 38 -...
Page 157
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Em erson Netw ork Pow er Co. L td. Maintenance Record Customer Company: Address: Zip Code: Contact person: Fax: Tel: Machine SN: Power: Model: Contract No: Date of purchase: Service provider: Contact person: Tel: Maintenance person: Tel: :...
Page 158
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312 Warranty Agreement 1. The scope of warranty is confined to the drive only. 2. Warranty period is 18 months, ENP conducts free maintenance and repair services to the drive that has fault or damage under the normal operation conditions. 3.
Page 159
Product Quality Feedback Form. Furthermore, if you can give us some advices on improving the product and service quality, you will be awarded a special gift. Thank you very much! Emerson Network Power Co., Ltd. Product Quality Feedback Form Tela...