Kta-20/Kta-20T Cybermount (Side Conduit Entry) - GE CyberDome Series Installation Manual

Cyberdome series
Table of Contents
CyberDome Series Installation Manual
A06-8SG0/B/April2006/1033921C

KTA-20/KTA-20T CyberMount (Side Conduit Entry)

Cabling will usually come out of the mounting surface and enter the CyberMount through the
rear opening in the base. For those applications where cabling is running along the mounting
surface and needs to enter the CyberMount through the side, these instructions are provided
for punching a hole that will accommodate a 1/2" conduit.
Step 1)
Loosen the two CyberMount cover screws enough to remove the cover (removing
the screws is not necessary). See Figure 63.
Step 2)
Remove the CyberMount cover and interface module. See Figure 63.
Step 3)
Align the template with the side of the CyberMount. See Figure 64.
Step 4)
Mark the center of the template's drill hole. See Figure 64.
Figure 63: Removing the Cover and Interface
Module of the CyberMount
CAUTION!
To maintain material integrity, DO NOT drill the conduit hole. Start with a pilot hole and enlarge it until
a knockout punch can be used to achieve the final hole size. (Hole sizes are given below.)
Step 5)
First, drill a 1/8 in. (.32 cm) pilot hole. See Figure 65.
Step 6)
Next, enlarge the pilot hole to 3/8 in. (.95 cm).
Step 7)
Finally, use a 1/2 in. (1.27 cm) conduit knockout punch to enlarge the hole to
7/8 in. (2.22 cm).
Figure 65: Drilling and Punching the Conduit Hole
Appendix A: Accessory Installation
Figure 64: Aligning the Template and Marking
the Drill Hole