GE CyberDome Series Installation Manual page 16

Cyberdome series
Table of Contents
Housing Installation
16
CAUTION!
DO NOT connect the 24VAC power cable to the video or RS422 connection in step 5 (below), or the
CyberDome will be damaged.
Step 5)
Connect the prepared cables to the interface module. See Figure 19.
There are two versions of the CyberDome interface module depending on whether
video is being sent via coaxial cable (CyberDome Coaxial Interface Module) or
unshielded twisted-pair wire (CyberDome UTP Interface Module).
NOTE: When using the CyberDome UTP Interface Module, the unshielded twisted-
pair video and RS422 control wires can share the same wire jacket, but must remain
as separate twisted pairs.
Step 6)
Insert the interconnect cable from the CyberDome into the RJ45 jack in the inter-
face module. See Figure 19.
Figure 19: Connecting the Cables to Either CyberDome Interface Module
Step 7)
Proceed to RS422 Termination on page 31.