Basic Parameter - Toshiba VF-S15 Instruction Manual

For 3-phase induction motors
Hide thumbs Also See for VF-S15:
Table of Contents
 Basic parameter 2
Communication
Title
No.

0170

0171

0172

0173

0185

0190

0191

0192

0193

0194

0195

0196

0197

0198

0199
 Frequency parameters
Communication
Title
No.

0200

0201

0202

0203

0204

0205

0206

0207
*1: Default setting values vary depending on the setup menu setting. Refer to section 11.5.
*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*12: When f701=1, adjustment range is 100%=rated current, or 100%=200V(240V class)/ 400V(500V class).
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Base frequency 2
Hz
0.1/0.01
Base frequency
V
1/0.1
voltage 2
Torque boost
%
0.1/0.1
value 2
Motor electronic-
%
1/1
thermal protection
(A)
level 2
Stall prevention
%
1/1
level 2
(A)
V/f 5-point setting
Hz
0.1/0.01
VF1 frequency
V/f 5-point setting
%
0.1/0.1
VF1 voltage
(V)
V/f 5-point setting
Hz
0.1/0.01
VF2 frequency
V/f 5-point setting
%
0.1/0.1
VF2 voltage
(V)
V/f 5-point setting
Hz
0.1/0.01
VF3 frequency
V/f 5-point setting
%
0.10.1
VF3 voltage
(V)
V/f 5-point setting
Hz
0.1/0.01
VF4 frequency
V/f 5-point setting
%
0.1/0.1
VF4 voltage
(V)
V/f 5-point setting
Hz
0.1/0.01
VF5 frequency
V/f 5-point setting
%
0.1/0.1
VF5 voltage
(V)
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Frequency priority
-
selection
VIA input point 1
%
1/1
setting
VIA input point 1
Hz
0.1/0.01
frequency
VIA input point 2
%
1/1
setting
VIA input point 2
Hz
0.1/0.01
frequency
VIA input point 1
%
1/0.01
rate
VIA input point 2
%
1/0.01
rate
Frequency setting
-
mode selection 2
Adjustment range
20.0-500.0
50-330 (240V class)
50-660 (500V class)
0.0-30.0
10-100 *12
10-199, *12
200 (disabled)
0.0-fh
0.0-125.0 *12
0.0-fh
0.0-125.0 *12
0.0-fh
0.0-125.0 *12
0.0-fh
0.0-125.0 *12
0.0-fh
0.0-125.0 *12
Adjustment range
0:  (Switchable to  by
-
terminal input)
1:  (Switchable to  at
1.0Hz or less of designated
frequency)
0-100
0.0-500.0
0-100
0.0-500.0
0-250
0-250
0-14 (Same as )
-
K-7
E6581611
Default
User
Reference
setting
setting
*1
6.8.1
*1
*2
100
5.6
6.8.1
6.29.1
150
6.8.1
6.29.2
0.0
6.3
6.9
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Default
User
Reference
setting
setting
0
5.8
6.10.1
0
6.10.2
7.3
0.0
100
*1
0
6.31
100
1
5.8
6.10.1
11