Hour Meter Function - Panasonic KW2G User Manual

Eco-power meter
Hide thumbs Also See for KW2G:
Table of Contents

5.5 Hour meter function

(KW2G/KW2G-H Main unit Ver.1.10 or more)
current
actual
work time
ON2
ON1
Cutoff
current
Available
Not
Maintenance
available
0
・When load current is under the setting current for time measurement (HM-A), it measures as OFF-time.
When load current is exceeded to the setting current for time measurement (HM-A), it measures as
ON-time. Current for time measurement (HM-A) is set to under cutoff current (CUTA), all current is
measured as OFF-time.
・Maintenance time
It measures maintenance time. Use it when you don't measure either OFF-time nor ON-time, for
example the load is under maintenance.
It measures ON signal input with the pulse input terminal as maintenance time. Actual work time is the
total time of ON-time2, ON-time1 and OFF-time.
Hour meter function can be used only with main unit and one expansion unit.
2 or more expansion units can't be used hour meter function.
・Ratio of ON-time
It displays ratio of ON-time calicurated with actual work time and ON-time as below.
[Calicuration method of Ratio of ON-time]
Ratio of ON-time1=ON-time1/(actual work time-Maintenace time) ×100(%)
Ratio of ON-time2=ON-time2/(actual work time-Maintenace time) ×100(%)
However, for ratio of ON-time, it uses measuring value inside every 1 sec., therefore it may be different
when you compare with displayed OFF-time, ON-time1, ON-time2, maintenace time and actual work
time.
①OFF-time
②ON-time1
Under cutoff current, it measures as 0A.
Not available
③ON-time2
④Maintenace time
51
KW2G-H Eco-POWER METER