Replacing The Slimline Odd Or Lsd; Required Tools; Preliminary Steps - Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual

Table of Contents

12.6.3 Replacing the slimline ODD or LSD

Upgrade and Repair Units (URU)
Average task duration: 10 minutes

12.6.3.1 Required tools

Preliminary and concluding steps: tool-less
Replacing a slimline ODD or LSD:
– Slotted screw driver (for bending in or out accessible drive mounting
brackets)

12.6.3.2 Preliminary steps

Before replacing a slimline ODD or LSD, perform the following steps:
Ê Locate the desired server as described in section
server" on page
Ê Remove all backup and optical disk media from backup and optical disk
drives as described in section
page
144.
Ê Shut down the server as described in section
page
71.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section
from the mains" on page
Ê When working on a rack-mounted server, extend it out of the rack as
described in section
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page
Ê Open the side / top cover as described in section
on page 79
(rack server) or
server).
TX300 S7 / RX350 S7
64.
"Removing backup and optical disk media" on
72.
"Extending the server out of the rack" on page
"Removing the side cover" on page 88
Upgrade and Maintenance Manual
Accessible drives
"Locating the defective
"Shutting down the server" on
"Disconnecting the server
77.
"Removing the top cover"
76.
(tower
735
Table of Contents
loading

This manual is also suitable for:

Primergy rx350 s7

Table of Contents