Ê When working on a rack-mounted server, extend it out of the rack as
described in section
If further required, remove the server from the rack as described in section
"Removing the server from the rack" on page
Ê Bring the server to its horizontal position.
Ê Open the side / top cover as described in section
on page 79
(rack server) or
server).
Ê Remove the air duct as described in section
on page
100.

10.2.3 Installing a memory module

Ê Identify the correct memory slot according to the mounting order described
in section
"Memory sequence" on page
Figure 404: Installing memory modules (A)
Ê Press out the securing clip at each end of the memory module connector.
I
For lack of space, it is necessary to remove the left rear fan (fan 5) in
order to install or remove memory modules in channels E and F. For
further information, please refer to section
module" on page
TX300 S7 / RX350 S7
"Extending the server out of the rack" on page
"Removing the side cover" on page 88
397.
Upgrade and Maintenance Manual
77.
"Removing the top cover"
"Removing the system air duct"
584.
"Removing a rear fan