8.2
Configuring the heating system
Contractor level: System configuration
An example system is shown in
chapter 2.5 on page 10. Other
examples can be found in the
instructions for the IPM or the
technical guides.
Use this menu if you want to configure the system
automatically or manually, e.g. when
commissioning or making changes to the system.
Connection type for the setting of the type of
•
connection with the Heatronic 3.
Start automatic system configuration for
•
starting automatic configuration.
Domestic hot water configuration for the
•
manual configuration of the DHW system.
CH system configuration for the
•
configuration of the assigned heating circuit.
DHW circulation pump: This menu point is
•
only active if a DHW circulation pump has
been installed in the DHW system.
Identification CH circuit for the selection of
•
the associated heating circuit (1 ... 10).
Menu settings INSTALLER SETTINGS (for contractors only) | 45
When commissioning a heating system, proceed
as follows:
B Code all BUS subscribers in accordance with
their function (e.g. IPM 1 for heating circuit 1
etc.).
B Start automatic configuration.
B Check the other menu points under System
configuration and, if necessary, adjust
manually to suit the current system.
For menu structure and setting ranges
page 42.
The heating system's solar thermal
system must be configured
manually (
chapter 8.4,
page 47). Automatic configuration
of the heating system does not
configure the solar thermal
system.
6 720 800 817 (2012/02)