Specifications (Technical Data) - Bosch C 1210 ES/ESC Manual

Natural gas liquefied petroleum gas indoor residential and commercial models
Table of Contents
3.2

Specifications (Technical data)

Approved in US/Canada
Technical characteristics
Capacity
Maximum flow rate at a 45 °F
(25 °C) rise
Maximum flow rate at a 63 °F
(35 °C) rise
Maximum flow rate at a 99 °F
(55 °C) rise
Maximum flow rate at a 135 °F
(75 °C) rise
Maximum flow rate at a 162 °F
(90 °C) rise
Maximum output
Maximum input
Thermal efficiency (Efficiency
in %)
Minimum Input
Temperature Control
C 1210 ES - Selection range
C 1210 ESC - Selection range
Default temperature
Stability
Gas Requirement
Gas connection
Inlet gas pressure under operation (with a high hot water flow rate)
Propane
Natural Gas
Water
Hot water connection
Cold water connection
2)
Minimum water flow
Minimum recommended water
pressure
Minimum well pressure
Water valve material
Connections:
Combustion
CO level
CO
level (set from factory)
2
Dimensions
Depth
Width
Table 3
C 1210 ES/ESC
Units
C 1210 ES/ESC
GPM (l/min)
9.2 (35)
GPM (l/min)
6.6 (25)
GPM (l/min)
4.2 (16)
GPM (l/min)
3.1 (12)
GPM (l/min)
2.6 (10)
BTU/hr (kW)
210,000 (61.5)
BTU/hr (kW)
225,000 (65.9)
%
> 94%
BTU/hr (kW)
25,000 (7.3)
°F ( °C)
100 - 140 (38) - (60)
°F ( °C)
100 - 180 (38) - (82)
°F ( °C)
122 (50)
 2 ( 1)
°F ( °C)
inches
¾ "
water column 8" - 13"
water column 3.5" - 10.5"
inches
¾ "
inches
¾ "
GPM (l/min)
0.5 (1.9)
PSI (bar)
30 (2.07)
PSI
40
Polymer (PPS)
(Polypropylene
Sulfide)
Bottom of heater
 290 (measured)
ppm
%
see table 33
inches (mm)
11 ¼ (286)
7
inches (mm)
17
/
(452)
8
Technical characteristics
Height
Weight
Gas types
Natural Gas
LP Gas
Voltage
Tension
Frequency
Amperage
Idle
Operation
Noise
3)
Water protection
Table 3
1) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.14, page page
31.
2) Activation varies with inlet water temperatures from 0.5 - 1.6 gallon/minute (1.9
- 6.1 l/m).
3) Protection against water drops.
If appliance is installed at elevations above 2000ft, refer
to chapter 4.3.7 Fan speed adjustment.
Safety devices
1)
• Flame failure device (ionization flame rod sensor)
• Overheat prevention (temperature limiter/ECO)
• Inlet temperature sensor
• Outlet temperature sensor
• Back flow temperature sensor
• Exhaust gas temperature sensor
Appliance details | 7
Units
C 1210 ES/ESC
inches (mm)
30½ (775)
pounds (kg)
74 (33.5)
V AC
120
Hz
60
mA
40
 2.5
A
db (A)
45 - 65
IP
X4D
6 720 644 887 (2013/02)

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

C 1210 esC 1210 esc

Table of Contents