Fig. 1
The chart below shows the relationship between water temperature and
time until there is a risk of scalding. It can be used as the basis for
determining the safest water temperature for your application.
Temperature
Time to severe scalding
120 °F (48 °C)
longer than 5 minutes
125 °F (51 °C)
1.5 to 2 minutes
130 °F (54 °C)
approx. 30 seconds
135 °F (57 °C)
approx. 10 seconds
140 °F (60 °C)
less than 5 seconds
145 °F (62 °C)
less than 3 seconds
150 °F (65 °C)
approx. 1.5 seconds
155 °F (68 °C)
approx. 1 second
Table 2 Approximate time-temperature relationship until there is a risk
of scalding
1) Source: Moritz, A.R. and Henriques, F.C., Jr. (1947). Studies of thermal injury. II.
The relative importance of time and surface temperature in the causation of
cutaneous burns, Am J of Pathol, 23, 695-720.
3

Appliance details

3.1

Features

Residential / Commercial models
• C 1210 ES residential model
6 720 644 887 (2013/02)
– maximum temperature 140 °F
• C 1210 ESC commercial model
– maximum temperature 180 °F
Parts
• Key Pad interface control.
• High power pre-mix compact burner with low NOx emissions.
• Modulating Gas Valve with constant gas:air ratio control.
• Modulating water valve for improved comfort and temperature
control.
High quality materials for long working life
• Copper heat exchanger.
• High efficiency Ceramat Burner.
• Compact space saver: mounts on a wall with a supplied bracket.
Features
• Easily removable one-piece cover.
• LCD Display with backlight
• On/Off and Temperature control buttons.
• Reset button.
• Program button (Selectable temperature default).
• Failure codes for easy diagnostics and repair.
• Real-time diagnostics for troubleshooting/informational purposes.
• Built in freeze prevention.
Note: The freeze prevention kit is designed to provide protection for the
water heater down to approximately 5°F for short term conditions only.
It will not protect the appliance in areas where the temperature is
routinely expected to be below freezing.
- The freeze prevention kit will not protect plumbing outside the
appliance from freezing. Precautions should be taken.
Accessories (Bosch part #)
• Optional wireless remote control to operate with the appliance
(TSTAT2)
• Cascading kit (7709003962)
• Outdoor kit (BTOK)
• External water filter (part # 8 703 305 356)
• Concentric termination kit (196016)
• Exhaust/Intake bird screen (L2594)
• Condensate drain tee (196061) [included with Concentric
termination kit]
• Pipe Cover (PTPCES)
1)
• High temperature kit (7736500074)
• Recess box kit (7736500043)
• Pressure relief valve 150 PSI (7738001152)