Panasonic VF0 Series 400V class Instruction Manual page 61

400v class compact inverter
Table of Contents
MONITOR SELECT and LINE SPEED MULTIPLIER
Used to select the details of the operation panel's main display.
[Parameter P60: Monitor details selection]
Data setting value
0
1
[Parameter P61: Line speed multiplier setting]
Used to set the multiplier with respect to the frequency when the line speed is displayed
on the operation panel's main display.
Data setting range
[Example: Display line speed ] ⇒ Line speed (m/min) = F (Hz) × K (multiplier)
· To display the line speed 25 (m/min) for 50Hz, set the multiplier (K) to "0.5".
Note) A line speed exceeding "999" cannot be displayed.
(The 4-pole motor speed cannot be displayed.)
MAX. OUTPUT VOLTAGE (Parameter P62)
Used to set the max. output voltage.
Data setting range (V)
Note 1) A voltage exceeding the power voltage
cannot be output.
Note 2) This setting does not affect the DC
brake level.
Details displayed on operation panel
Output frequency
Line speed
0.1 to 100 (can be set in 0.1 units)
0 • 1 to 500
(When "0" is set, the power voltage value will be output.)
(Parameter P60 and P61)
Max. output voltage
Base frequency
Output frequency
Power voltage
60