BIAS/GAIN FUNCTION SELECT, BIAS FREQUENCY,
GAIN FREQUENCY (Parameter P55, P56 and P57)
The relation with the output frequency and frequency setting signal (panel potentiometer,
external potentiometer, 0 to 5V, 0 to 10V, 4 to 20mA), can be changed randomly. Use this
function according to the application.
[Parameter P55: Bias/gain function select]
Data setting range
0
1
[Parameter P56: Bias frequency setting]
Data setting range
[Parameter P57: Gain frequency setting]
Data setting range
(When "000" is set, 0V stop will function.)
Note 1) A frequency exceeding the maximum output frequency or upper frequency clamp
cannot be output.
The frequency will not drop below the lower frequency clamp.
Note 2) Even if a minus frequency setting signal is input, the inverter will not run in reverse.
[When bias frequency setting is positive]
Max. output frequency
(Parameter P03, P15)
Frequency setting
signal
Bias frequency
(Parameter P56)
Function details
Bias/gain function disabled
Bias/gain function enabled
(Hz) –99 to 250
(Hz) 000 and 0.5 to 250
Gain frequency
(Parameter P57)
100%
Bias frequency
(Parameter P56)
[When bias frequency setting is negative]
Max. output frequency
Gain frequency
(Parameter P03, P15)
(Parameter P57)
100%
Frequency setting
signal