WHAT IS A PROGRAMMER?
...an Explanation for Householders (as recommended by the Energy Savings Trust)
Programmers allow you to set 'On' and 'Off' time periods. Some models switch the central heating
and domestic hot water on and off at the same time, while others allow the domestic hot water
and heating to come on and go off at different times. Set the 'On' and 'Off' time periods to suit
your own lifestyle. On some programmers you must also set whether you want the heating and hot
water to run continuously, run under the chosen 'On' and 'Off' heating periods, or be permanently
off. The time on the programmer must be correct. Some types have to be adjusted in spring and
autumn at the changes between Greenwich Mean Time and British
Summer Time. You may be able to temporarily adjust the heating
programme, for example, 'Override', 'Advance', or 'Boost'. These
are explained in the manufacturer's instructions. The heating will
not work if the room thermostat has switched the heating off. And,
if you have a hot-water cylinder, the water heating will not work if
the cylinder thermostat detects that the hot water has reached the
correct temperature.
This product and its associated documentation and packaging are protected by various intellectual
property rights belonging to Honeywell Inc. and its subsidiaries and existing under the laws of the UK
and other countries. These intellectual and property rights may include patent applications, registered
designs, unregistered designs, registered trade marks, unregistered trade marks and copyrights.
Honeywell reserves the right to modify this document, product and functionality without notice. This
document replaces any previously issued instructions and is only applicable to the product(s)
described.
This product has been designed for applications as described within this document. For use outside of
the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible
for misapplication of the product(s) described within this document.
Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell
Technologies Sarl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell Inc.
Honeywell Control Systems Ltd.
Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
50022737-003 A
Technical Help Desk: 08457 678999
www.honeywelluk.com
© 2007 Honeywell International Inc.
ST9100S – User Guide
1 Day Timer, 1 channel
With Boiler Service Reminder / Shut-down Feature
This document is to be left with the user
and forms part of a Home Information Pack
Features
Easy to use slider and buttons combined with 'LoT'™ Technology and an
'OK' button, allows you to confirm changes and stay in control.
LoT™ Technology provides you with informative 'on-screen' feedback and operational
assistance as and when required.
Extra Large LCD (Liquid Crystal Display) with Backlight provides added user
friendliness and clearer viewing – even in the dark.
1-day Programme lets you choose settings built into ST9100S to match your lifestyle,
while maximising energy savings, or alter them to your personal settings.
Automatic Summer/Winter Time Change will adjust the clock forward and backward
automatically when the clocks change, saving you having to change your ST9100S
every time.
Built-in Memory holds your programme indefinitely - even if the mains power fails.
Boiler Service Reminder / Shut-down provides a reminder for when the boiler
service is due, and, if necessary, shuts down to ensure your safety.
Energy Efficiency and the Environment
Home energy use is responsible for more than ¼ of the total UK carbon emissions
which contribute to climate change. Heating and hot water systems based on
boilers account for
of this figure, so it is important to understand how your
controls can help to maximize energy efficiency while maintaining your comfort.
Your Timer should be used in conjunction with appropriate temperature controls. In
order to save energy the following general points should be observed:
1. Ensure your system contains a room thermostat and a hot water thermostat,
and that both are set to appropriate temperature levels: typically 20°C for the
room temperature and between 55 - 60°C for the hot water temperature.
2. Programme your heating and hot water to be off when you are not in the house. If
you are concerned about possible frost damage to any exposed pipe work, it is
advisable to fit a frost protection system – your installer can advise you about this.
3. Think about how you use your domestic hot water – if you have a storage
system, it is not necessary to have this switched on all the time, even when you
are in the house.
4. Consider the heat up times required for your central heating. Every home
responds differently when the heating is switched on. Adjust the start time so
that you are not cold when you get up in the morning. A shorter heat up time is
required for other heating periods.
5. In the evening, when the house is up to temperature, it is often possible to
switch off the heating up to an hour before you go to bed, without any noticeable
reduction in comfort.
Table of Contents
loading

Summary of Contents for Honeywell ST9100S

  • Page 1 Honeywell Inc. and its subsidiaries and existing under the laws of the UK and other countries. These intellectual and property rights may include patent applications, registered Your Timer should be used in conjunction with appropriate temperature controls.
  • Page 2: Table Of Contents

    FAQ & TROUBLESHOOTING LoT™ Technology Display Slider How do I set the time only, if the ST9100S clock is not correct? ....14 What do I do when the clocks go back in October and forward in March? .14 Programme Time Markers Operating Mode Button What should I do if I get ‘lost’...
  • Page 3: General Description

    ST9100S has 1-day programming and 2 on/off periods per day, making it very simple to use. ST9100S also has a Boiler Service reminder / Shut-down feature, which helps ensure your gas boiler is regularly serviced in compliance with UK Gas Safety regulations.
  • Page 4: Getting Started With Your St9100S

    Step 1: Setting the Date & Time Your ST9100S had the date and time set at the factory, and these are normally maintained by a backup battery in the event of power failures. If you wish to change the date or time, or if the LoT™...
  • Page 5: Step 2: Running A Built-In Programme

    Step 2: Running a Built-in Programme With the date and time correct, your ST9100S Timer will now be operating to the built-in programme. This has been designed to provide heating at typical times throughout the day, but if you want to customise the settings, please see the next...
  • Page 6: The Built-In Programmes

    The table below has been left blank for you to record your own personal programme. For ease of use, your ST9100S is supplied as standard with only 2 on/off’s enabled. To enable ON/OFF period 3 see Fine Tuning your ST9100S (page 12).
  • Page 7: Reviewing The Programme Times

    PrOGrAmmING YOUr ST9100S reviewing the Programme Times To review your programme, move the slider to the PrOGrAmme position. To review the programme times, press the button repeatedly. The appropriate ON and OFF markers will be displayed to show you which time is being reviewed.
  • Page 8 OFF marker may start to flash. This indicates you have tried to set a time equal to one of the previous programme times. If this happens the ST9100S simply moves both times together as long as you continue to press the buttons.
  • Page 9: Exiting Programming Mode

    PrOGrAmmING YOUr ST9100S exiting Programming mode: To exit programming mode, move the slider to the rUN position. This can be done at any time during the programming process, and any changes made and confirmed with the button will have been saved.
  • Page 10: Operating Your St9100S

    OPerATING YOUr ST9100S Choosing the Operating mode The operating mode may only be changed when the slider is set to the rUN position. DAY/TIME A green INDICATOr LAmP shows when the system is switched PROGRAMME A mODe button is provided to select the Operating Mode and therefore how the system is controlled.
  • Page 11: Override The Operation Without Changing The Programme

    OPerATING YOUr ST9100S Overriding the Operation Without Changing the Programme In AUTO and ONCe operating modes, the OVerrIDe button switches the system ON or OFF without altering the programme. When the indicator lamp is ON, pressing the OVerrIDe button switches the system OFF until the next programmed ON time.
  • Page 12: Fine Tuning Your St9100S

    Changing from Am/Pm Time Display to the 2 Hour Clock Your ST9100S can operate on the 12 hour AM/PM or 24 hour clock formats. To change the format, ensure the slider is in the rUN position then press and hold the buttons together for about 2 seconds.
  • Page 13 FINe TUNING YOUr ST9100S To enter Installer mode: a. Ensure the slider is in the rUN position, then press and hold buttons together for 8 seconds. Ignore the ‘NOT VALID’ message that is displayed for a few seconds. The message ‘SET UP MENU’ will show briefly, followed by ‘SET INSTALLER OK ?’...
  • Page 14: Faq & Troubleshooting

    What should I do if I get ‘lost’ while programming the ST9100S? The LoT™ Display on ST9100S will provide you with help and tips to work through the programming. Should you ever get ‘lost’, the simplest thing to do is to move the slider to the rUN position, and then move it back to the appropriate programming position where you got lost.
  • Page 15: Troubleshooting Guide

    FAQ AND TrOUBLeSHOOTING Troubleshooting Guide This is a quick guide to help you diagnose and cope with possible problems with ST9100S. For further assistance, please contact your Installer. Symptom Possible Cause remedy ST9100S has a blank No power to the...
  • Page 16: Boiler Service Reminder

    These features will be programmed by your Installer, maintenance Engineer, or Landlord. • If it has been set to do so, ST9100S will display a message on the screen to remind you that a boiler service is due. •...
  • Page 17: Shut-Down

    BOILer SerVICe remINDer Shut-down If your ST9100S shows the words “SerVICe DUe” and “OFF” then your boiler service is OVerDUe and the boiler has been automatically switched off to ensure your safety – you should arrange an immediate service visit.
  • Page 18: Configuration & Service Data

    CONFIGUrATION & SerVICe DATA Configuration Data (to be completed by Installer) The table below is for the Installer to complete to indicate how your ST9100S has been configured. Configurable Options Installer Configured Features tick appropriate box) 24hr or am/pm clock...