Panasonic JS-170FR Series Service Manual page 120

Front counter register
Table of Contents
15) Inline test
15-1) LAN-ID setting
(1) Enter "14-ENTER" through the keyboard.
(2) Enter "1-ENTER" through the keyboard. (For Set Configuration, only keyboard can be operated.)
0 : EXIT
1 : Ethernet Address ************
2 : Set EEPROM
(3) Enter "1-ENTER" through the keyboard.
Ethernet Address Set
Set and press ENTER key
(4) After entering an Ethernet Address input, enter "ENTER" through the keyboard.
(5) If the contents of setting are checked and known to be correct, enter "2-ENTER" through the keyboard.
(6) Enter any key input.
(7) Enter "0-ENTER" through the keyboard. (To the Inline Test Menu)
(8) Enter "0-ENTER" through the keyboard. (To the Main Menu)
(9) Enter "0-ENTER" through the keyboard. (Withdrawal from the diagnostic program)
LCD DISPLAY
***** TEST # 14 Inline Test. *****
0 : Return to MAIN MANU
1 : Set Configutation
2 : Send Data
3 : Receive Data
4 : Self Test
Select and press ENTER key : 0
LCD DISPLAY
***** TEST # 14 Inline Test. *****
Select and press ENTER key : 0
LCD DISPLAY
***** TEST # 14 Inline Test. *****
1234567890AB
3-36