Panasonic JS-170FR Series Service Manual page 116

Front counter register
Table of Contents
13) Magnetic Card test
(1) Prior to turning ON the FR power supply, connect a magnetic card reader unit (JS-140MG-XXX or JS-170MG-010).
(2) Turn on the power supply and confirm that the LED for the magnetic card is lit in green.
(3) Enter "12-ENTER" through the keyboard.
(4) Let the magnetic card reader unit read out a card in the reverse direction and confirm that the LED for the magnetic
card is lit in red.
(5) Let the magnetic card reader unit read out a card in the forward direction and confirm that the LED for the magnetic
card is not lit in red. Confirm also that the card data are correctly displayed on the screen.
When the JS-140MG is used (JIS1 track 2/ISO2 card is used.)
***** TEST # 12 Magnetic Card Reader Test. *****
Magnetic Card Data
F1=STOP / CONTINUE
When the JS-170MG is used (JIS1 track 2/ISO2 card + JIS1 track 1/ISO1 card are used)
***** TEST # 12 Magnetic Card Reader Test. *****
Magnetic Card Data
*******************************?*
F1=STOP / CONTINUE
Main PWB SW1 setting
LCD DISPLAY
OK
B*****F*
Values somewhat change according
to the card presently used.
F2=STOP / MENU
Main PWB SW1 setting
LCD DISPLAY
OK
B****************************F*
%*********************************
Values somewhat change according
to the card presently used.
F2=STOP / MENU
3-32
1
2
3
4
ON
ON
1
2
3
4
ON
OFF
5
6
ON
ON
5
6
ON
ON
Table of Contents
loading

Table of Contents