(1) Pilot lamp indication
The indications of the pilot lamp will be as shown
in Table 2, according to the condition of the charger
or the rechargeable battery.
The pilot
Before
lamp lights
charging
or blinks in
red.
While
charging
Charging
complete
Charging
impossible
The pilot
Overheat
lamp lights
standby
in green.
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in Table 3, and batteries that have
become hot should be cooled for a while before
being recharged.
Table 3
Rechargeable
Temperatures at which the
batteries
battery can be recharged
BSL1830
32°F —122°F (0°C — 50°C)
4.
Disconnect battery charger from the receptacle.
CAUTION:
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5.
Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary
phenomenon, and normal time required for
recharging will be restored by recharging the
batteries 2 – 3 times.
01Eng_DS18DSDL_US1
Table 2
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
Blinks
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Flickers
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Lights
Lights continuously
(1) Recharge the batteries before they become
(2) Avoid recharging at high temperatures.
13
Malfunction in the battery
or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
How to make the batteries perform longer.
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its
battery. If you continue to use the tool and exhaust
the electric current, the battery may be damaged
and its life will become shorter.
A rechargeable battery will be hot immediately
after use. If such a battery is recharged immediately
after use, its internal chemical substance will
deteriorate, and the battery life will be shortened.
Leave the battery and recharge it after it has cooled
for a while.
CAUTION
● When the battery charger has been continuously
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes rest
until the next charging.
● If the battery is rechraged when it is warm due to
battery use or exposure to sunlight, the pilot lamp
may light in green.
The battery will not be recharged. In such a case,
let the battery cool before charging.
● When the pilot lamp flickers rapidly in red (at 0.2–
second intervals), check for and take out any
foreign objects in the charger's battery installation
hole. If there are no foreign objects, it is probable
that the battery or charger is malfunctioning. Take
it to your authorized Service Center.