3. Enter the code 009 #LL #, where LL represents the length
(number of digits in a code). The range is from 04 to 08 digits.
You can leave the factory default Access Code length
(4 digits) if you wish.
4. Example of Complete Entry: 009#05#.
5. Key in another # to indicate the end of programming.
6. From now on, all the Access Codes you create must be the
length specified in this step, which is 5 digits.

Procedure 2 - Modify the Master User Access Code

Required User Level: Master
1. To change the factory code or current Master Code, follow the
next three steps:
2. Put lock into Pushbutton Programming Mode.
3. Use the command, 000, for Master, then the new Master
Code number.
4. You must use 8 digits between 00000000 and 99999999 as follows:
000#MMMMMMMM#, we'll use 000#87654321# as an example.
5. Enter the Master Code again 87654321# for confirmation.
6. Example of Complete Entry: 000#87654321#87654321#.
7. Key in another # to indicate the end of programming.
8. After that, you will always use your own Master Code. Please
write the code down and keep in a safe place. The factory
code is no longer valid.
Required User Level: Master

Procedure 3 - Program the Unlock Time

Unlock time is the length of time the door will remain unlocked when a
correct code is entered before automatically re-locking itself.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. To establish Unlock Time, enter the following code: 004#TT#,
where TT is the time in seconds, (TT=02 to 20 seconds, for
example 10 seconds).
8
3. Example of Complete Entry: 004#10#.
4. Enter another # to indicate the end of programming.
5. You have now programmed an Unlock Time of 10 seconds for
the door.
Procedure 4 - Program the Duration of the Passage
Mode Period
You might want to program locks for public areas, such as cafeterias, to
have free access (Passage Mode) during certain periods of the day, and
revert to required code access outside of these regular hours.
The length of time that the lock remains in Passage Mode is programmable.
The factory default length of time for Passage Mode is 9 hours - you may
leave the default.
Once the lock has been put into Passage Mode, it will automatically
relock after the designated duration.
Required User Level: Master, Manager
1. Put the lock into Pushbutton Programming Mode.
2. Enter command code 005#.
3. Then TT#, where TT= 01 to 24 hours.
4. A TT entry of 00 means there is no time limit - the door
remains unlocked.
5. Enter 005 #TT#; for example, 005#06# for six hours.
6. Example of Complete Entry: 005#06#.
7. Enter another # to indicate the end of programming.
8. In this example, the lock will remain unlocked for six hours,
starting from the time you put it in Passage Mode.
9. You have now configured the duration of the Passage Mode
period for that lock. This does NOT initiate Passage Mode.
10. The new length of time will take effect the next time you
put a lock into Passage Mode by following the correct
command sequence.