  • Page 4: Introduction

    INTRODUCTION The E-Plex 2000 (E2000) and the E-Plex PowerStar 2000 (EPS2000) are both easy to use PIN only lock series that do not require any software to operate. E2000 Operation The E2000 uses three (3) AA alkaline batteries. This means that...
  • Page 5 Important: When you pump the handle, the lock will flash the Green light once accompanied by a high pitched beep indicating that it is “ready”—either for you to enter your valid access PIN, or for you to start programming. If you do not pump the handle, there will be no response from the lock and consequently there will be no access granted.
  • Page 6: States Of The Lock

    STATES OF THE LOCK Factory Mode The factory mode is one of three primary states of the E-Plex 2000 and the E-Plex PowerStar 2000. The main characteristics of this state are: • The E2000/EPS2000 opens only when the 8-digit master combination (1-2- 3-4-5-6-7-8) is keyed in.
  • Page 7: Default Values Of The E-Plex 2000 Programmable Parameters

    DEFAULT VALUES OF THE E-PLEX 2000 PROGRAMMABLE PARAMETERS Parameters Factory Default Values Lock state Unprogrammed Passage mode open time limit 9 hours Passage mode De-Activated Lockout mode De-Activated Unlock time 2 seconds Buzzer volume control Tamper shutdown time 30 seconds...
  • Page 8: Reset Procedures

    Reset Procedures There are three different “Reset” levels available in the E-Plex 2000. Code 099# will reset the lock to the factory default settings except for the access code length (Master and Manager User codes are retained if already...
  • Page 9: Program The Access Code Length

    The master code must always be 8 digits Required User Level: Master A-1 To configure the E-Plex 2000 programmable pushbutton lock, it must first be placed in Programming Mode. Important: This is the only programmable function that can be done during the factory mode using the factory master code.
  • Page 10: Program The Unlock Time

    C. PROGRAM THE UNLOCK TIME Unlock time is the length of time the door will remain unlocked when a correct code is entered before automatically re-locking itself. Required User Level: Master, Manager Put the lock into Pushbutton Programming Mode. C-2 To establish Unlock Time, enter the following code: 004#TT#, where TT is the time in seconds, (TT=02 to 20 seconds, for example 10 seconds).
  • Page 11: Program The Lock For Tamper Time Parameters

    E. PROGRAM THE LOCK FOR TAMPER TIME PARAMETERS You can set a Tamper Time Wrong Tries parameter referring to the number of times the wrong code can be entered before the lock goes into Tamper Shutdown Mode. For example, if you program the lock to accept three wrong tries, the lock will tolerate three wrong entries, staying locked but providing visual feedback (see visual message chart in rear section).
  • Page 12: Users - General Information

    F-3 Example of Complete Entry: 008#02#. F-4 Enter another # to indicate the end of programming. F-5 The lock will now sound the buzzer at the desired volume Normal, until you change it. Users - General Information 1. Master and Manager Codes can do two different things: •...
  • Page 13: User Codes

    Service User - A user with an Access Code valid for a configurable period of time. This period of time starts on the first use of the code. Each Service User combina- tion is automatically deleted after its period of time expires. The number of service users is limited only by available user table space (99 maximum because one (000) is reserved for the Master Code).
  • Page 14 (2) years from initial instal- lation date. Kaba Access Control will repair or replace, at our discre- tion, E-Plex 2000 Locks found by Kaba Access Control analysis to be defective during this period. Our only liability, whether in tort or in con-...
  • Page 17: Add/Modify A User Access Code

    G. ADD/MODIFY A USER ACCESS CODE • When users no longer need access to the lock, delete the User Code. This permits you to use the number for a new user. • If you only de-activate the old code, you cannot add a user with the same number.
  • Page 18: Add/Modify Service User Access Code

    H-5 Enter the code 1224# again. H-6 Example of Complete Entry: 101#024#1224#1224#. H-7 Enter another # to indicate the end of programming. H-8 The Manager Access Code 1224 will now work in that door with all the access privileges assigned to a Manager User. H-9 Manager Users can open the door by just entering the Access Code without the # signs, or put the lock into Pushbutton Programming Mode by entering # before and after their Access Code.
  • Page 19: Delete User Access Codes

    J. DELETE USER ACCESS CODES User Access Codes should be deleted if no longer needed. This frees the num- bers to be assigned to another user. Codes that may be needed some time in the future should be de-activated rather than deleted. Required User Level: Master, Manager Put the lock into Pushbutton Programming Mode.
  • Page 20: Delete All Access Codes Except Master And Manager

    L-4 Example of complete entry: 202#025#. L-5 Enter another # to indicate the end of programming. L-6 You have now deleted a Service User ID location, and (indirectly) his access code, allowing you to assign that number to another Service User if you wish. M.
  • Page 21: Activate Manager Access Code

    O. ACTIVATE MANAGER ACCESS CODE A Manager Code should be activated if it has been de-activated for a certain time period - during a Manager’s vacation, for example, or if you created a Manager’s Code, but never assigned it to anyone. Required User Level: Master O-1 Put the lock into Pushbutton Programming Mode.
  • Page 22: Activate/De-Activate Passage Mode

    R. ACTIVATE/DE-ACTIVATE PASSAGE MODE You have already programmed a default duration for a door to remain in Passage Mode. When you enable Passage Mode, it becomes enabled for the duration you have set in Procedure 5 - Program the Duration of the Passage Mode period, on page 9.
  • Page 23: De-Activate Service User Access Code

    Required User Level: Master Put the lock into Pushbutton Programming Mode. T-2 Enter Command 401# to de-activate a Manager Access Code. Enter the code 401#NNN#, where NNN is the specific Manager ID location, 024 for example. T-4 Example of complete entry: 401#024#. T-5 Enter another # to indicate the end of programming.
  • Page 24: Activate/De-Activate Lockout Mode

    W. ACTIVATE/DE-ACTIVATE LOCKOUT MODE You may need to use Lockout Mode, for example, during a fire or fire drill when you do not want anyone to return to his or her office. This procedure will de- activate all regular User Access Codes that are active, including Manager Codes, but excluding the Master Code.
  • Page 25: Battery Life And Replacement

    In average conditions, you can expect a minimum of 100,000 openings for E-Plex 2000 models with 3 “AA” Alkaline Batteries. A Low Battery condition is identified by a flash of both red and green LEDs when a valid access code is entered and the lock will still give access.
  • Page 26 Summary of Pushbutton Programming Commands Name Command Description of Command Authorization Add/Modify 100 # ‘Add/Modify User Access Code’ NNN = spe- Master, Mgr Users cific User ID location (001 to 099) NNN # (Combination length can be 4 to 8 digits, UUUU {UUUU}# depending on access length LL setting) UUUU {UUUU}#...
  • Page 27 Summary of Pushbutton Programming Commands Name Command Description of Command Authorization Activate 300 # ‘Activate User Access Code’ Master, Mgr Users NNN# NNN = specific User ID location (001 to 099) Master 301 # ‘Activate Manager Access Code’ NNN# NNN = specific User ID location (001 to 099) Master, Mgr 302 # ‘Activate Service User Access Code’...
  • Page 28: Visual Feedback Message Definitions

    Visual Feedback Message Definitions Condition Parameters Green LED Red LED Duration Rate Valid pushbutton 1/10 sec Once pressed Timeout expired 1 sec; A Once Valid access 1 sec Once code keyed Access granted 1/10 sec 1 sec Access granted 1/10 sec 1 sec (battery low condition Access denied...
  • Page 29: User List Table

    E-Plex 2000 User List Table User # Access Code User Name User Type...