Alarm; Connections; Connecting To The Biphase; Direct Control - Bosch VEZ Series Installation And Configuration Manual

Autodome easy
Hide thumbs Also See for VEZ Series:
Table of Contents
AutoDome Easy
4.4

Alarm

The recommended optional alarm input cable is a 2-conductor, 18-22 gage cable, depending
on the distance. Refer to the wiring distance guide Table 4.1 on page 5.
AWG
22
18
Table 4.1 Wiring Distance Guide
5

Connections

Follow the instructions below to terminate all connections as described.
Color
Black
Brown
Red
Orange
Blue
Violet
Table 5.1 Connection Cable Description
5.1

Connecting to the Biphase

The AutoDome Easy camera can be controlled remotely by an external device or control sys-
tem, such as a control keyboard, using biphase.
5.1.1

Direct Control

To connect the biphase configuration, do the following:
1.
2.
3.
4.
AutoDome Easy
Fig. 5.1 Biphase Direct Control
Bosch Security Systems, Inc.
Wire Size
Maximum Distance
mm
feet
meters
0.644
500
152.4
1.024
800
243.8
Description
Biphase (+)
Biphase (-)
AC24 V / DC12 V
AC24 V / DC12 V
ALARM COMMON
ALARM IN
Locate the cable assembly with a two (2) pin black mating connector on one end and the
brown and black flying leads on the other end.
Connect the biphase+ from the controller to the black lead and secure.
Connect the biphase- from the controller to the brown lead and secure.
Connect shield of the cable to the Head End controller.
Brown
Black
Not Connected X
Installation and Configuration Manual
Connections
Head End
Biphase
C-
C+
SHIELD
December 06, 2006 | F01U074570 | 3.0