Bosch VEZ-400 Series Operation Manual

Autdome 4000 mini ptz
Hide thumbs Also See for VEZ-400 Series:
AUTDOME 4000 Mini PTZ
Dome
VEZ-400 Series
en
Operations Manual
Table of Contents
loading

Summary of Contents for Bosch VEZ-400 Series

  • Page 1 AUTDOME 4000 Mini PTZ Dome VEZ-400 Series Operations Manual...
  • Page 3: Table Of Contents

    Setting the protocol of the camera On-Screen Display (OSD) Menu Basic Navigation and Common Actions Main Menu 7.2.1 Editing Titles 7.2.2 Clearing Saved Functions System Setup Menu 7.3.1 System Information 7.3.2 Reboot 7.3.3 Initialize 7.3.4 Password Display Setup Bosch Security Systems, Inc. 2013.4 | |...
  • Page 4 Dome Motion Setup 7.6.1 General Setup 7.6.2 Motion Setup 7.6.3 Home Action 7.6.4 Calibration Preset Setup Pattern Setup Tour Setup 7.10 Scan Setup 7.11 Alarm Setup Troubleshooting Technical Specifications Dimensions Bosch Protocol Pelco Protocol 2013.4 | | Bosch Security Systems, Inc.
  • Page 5: Safety

    If not avoided, this could result in property damage or risk of damage to the unit. Notice! This symbol indicates information or a company policy that relates directly or indirectly to the safety of personnel or protection of property. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 6: Important Safety Instructions

    Only use attachments/accessories specified by the manufacturer. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use caution when moving the cart/apparatus combination to 2013.4 | | Bosch Security Systems, Inc.
  • Page 7 Bosch Security Systems, Inc. 2013.4 | |...
  • Page 8: Important Notices

    When unregulated power supply is applied, product warranty will be void. Bosch recommends using the camera with a monitor that has a CCTV-quality 75 Ohm video impedance level. If your monitor is switched to high impedance, please adjust accordingly.
  • Page 9 Bosch Security Systems, Inc. 2013.4 | |...
  • Page 10 AUTDOME 4000 Mini en | Safety PTZ Dome Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
  • Page 11 Network Voltage (TNV) circuits. The system ground is only used to comply with safety standards or installation practices in certain countries. Bosch does not recommend connecting system ground to safety ground unless it is explicitly required. However, if the system ground and...
  • Page 12: Fcc & Ices Compliance

    PTZ Dome Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 13 Cet appareil génère, utilise et émet de l'energie de fréquence radio, et peut, en cas d'installation ou d'utilisation non conforme aux instructions, engendrer des interférences nuisibles aux radiocommunications. Toutefois, rien ne garantit l'absence Bosch Security Systems, Inc. 2013.4 | |...
  • Page 14 Resolve Radio-TV Interference Problems (Comment identifier et résoudre les problèmes d’interférences de radio et de télévision). Cette brochure est disponible auprès du U.S. Government Printing Office, Washington, DC 20402, États-Unis, sous la référence n° 004-000-00345-4. 2013.4 | | Bosch Security Systems, Inc.
  • Page 15: Bosch Notices

    PERFORMANCE OR RELIABILITY OF ANY SECURITY- OR SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT. Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
  • Page 16 The ongoing development of products means that the content can change without notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults, incompleteness or discrepancies between this manual and the product described.
  • Page 17: Description

    2/8 Tours (consisting of Presets, Patterns, and Scans) – 4 Alarm inputs, 1 Alarm output (Off/N.C./N.O.) – Programmable PTZ Speed: Proportional to Zoom ratio, changeable preset speed – OSD with multiple display languages – Privacy mask zones Bosch Security Systems, Inc. 2013.4 | |...
  • Page 18 The AUTDOME 4000 Mini PTZ Dome uses a 30X zoom lens (fW=3.49 ±0.17mm fT=104.02 ±5.20mm). The polycarbonate bubble (part of the camera housing) causes image distortion, reducing the optical zoom performance. The effective optical zoom ratio is 26X +/- 10%. 2013.4 | | Bosch Security Systems, Inc.
  • Page 19: Unpacking

    Save it for possible future use. Verify that all the parts listed in the Parts List are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. Parts List...
  • Page 20 Make sure that appropriate mounting screws, rubber O-rings, and anchors are used for the surface to which the camera is mounted. The supplied plastic anchors and mounting screws are only suitable for mounting the camera on a concrete ceiling. 2013.4 | | Bosch Security Systems, Inc.
  • Page 21: Additional Tools Required

    No. 2 Phillips screwdriver – Drill with appropriate bit for pre-drilling anchor holes – Appropriate tool for cutting a hole in drywall or ceiling tile (if applicable) Accessories The following accessories are available for the camera: Bosch Security Systems, Inc. 2013.4 | |...
  • Page 22 PTZ Dome Model Description Drawing Number VEZ-A4-IC AUTDOME 4000 In- ceiling Mount (Charcoal color and white color ceiling plate included) VEZ-A4-PC AUTDOME 4000 Pipe mount (Charcoal color) AUTDOME 4000 VEZ-A4-PW Pipe mount (White color) 2013.4 | | Bosch Security Systems, Inc.
  • Page 23 AUTDOME 4000 Mini Unpacking | en PTZ Dome Model Description Drawing Number VEZ-A4-WC AUTDOME 4000 Wall mount (Charcoal color) VEZ-A4-WW AUTDOME 4000 Wall mount (White color) Bosch Security Systems, Inc. 2013.4 | |...
  • Page 24: Installation Overview

    In-ceiling mount, used in applications where the camera is mounted into a recessed ceiling. The installation should be made by qualified installation personnel and conform to the National Electrical Code and applicable local codes. 2013.4 | | Bosch Security Systems, Inc.
  • Page 25: Installing A Surface Mount

    Installing a Surface Mount Use the following illustration as a guide for installing the camera directly onto the ceiling (surface mount): Figure 5.1: Mounting diagram Numbe Description Drilling template 6 x 30 mm plastic anchor Bosch Security Systems, Inc. 2013.4 | |...
  • Page 26 Insert the four plastic anchors (item 2) inside the pre- drilled holes. Route the cables from the camera through the conduit in the ceiling. Remove the dome cover (item 6) from the camera base (item 3). 2013.4 | | Bosch Security Systems, Inc.
  • Page 27 13. Attach the dome cover to the camera base using the four M4 x 12 Torx screws (with O-rings (item 4) attached) using the supplied Torx wrench. Make sure that the large rubber O-ring between the camera base and dome cover is in place Bosch Security Systems, Inc. 2013.4 | |...
  • Page 28 O-rings seal the dome cover against water ingress. 14. Remove the plastic film protecting the dome cover from scratches. 2013.4 | | Bosch Security Systems, Inc.
  • Page 29: Connection

    To prevent humidity problems, the camera must be installed in dry conditions, and the cable leads should be sealed once connected. Use the following illustration as a guide for preparing and connecting the wiring: Bosch Security Systems, Inc. 2013.4 | |...
  • Page 30 4 8-pin I/O terminal (Alarm In/Out) 5 2-pin data terminal (RS-485 Connection) 6 Video Out (Female BNC connector) 7 Video In to monitor (Male BNC connector) 8 CCTV Monitor 9 Bosch keyboard controller 2013.4 | | Bosch Security Systems, Inc.
  • Page 31: Rs-485 Connections

    RS-485 duplexer. The total length of the cable for communication should not exceed 1 km (3937 ft). If the distance between the camera and the control room is greater than 1 km (3937 ft), Bosch recommends using a repeater (not supplied). Notice! The wire shield must be tied to signal at both ends, if 2-wire twisted pair is used.
  • Page 32 RxB, and TRX- should be connected to RxA. The camera's baud rate should be set to 9600, and the protocol should be set to Bosch OSRD. Also make sure that the camera ID is configured correctly. For further details on setting up the MIC-BP3, please refer to the separate MIC-BP3 Bi-Phase Converter Card Installation and Operation Manual.
  • Page 33: Video Connection

    Wire alarms either Normally Open (N.O.) or Normally Closed (N.C.); you must program the alarm inputs N.O. (the default) or N.C. through the on-screen display menus. The following table summarizes the maximum distances for alarm wires: Bosch Security Systems, Inc. 2013.4 | |...
  • Page 34 Use the following table to connect alarm wires to the 8-pin terminal block from the camera: Number Signal Color Yellow Orang Green Blue Black Violet Gray Brown Table 6.4: 8-pin Terminal Block Connections 2013.4 | | Bosch Security Systems, Inc.
  • Page 35: Power Connections

    When (re)mounting the dome cover to the camera base, ensure that each screw has a rubber O-ring, and that the large rubber O-ring is in place on the camera base. This ensures protection against water ingress. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 36 AUTDOME 4000 Mini en | Connection PTZ Dome Figure 6.2: Dome Camera Switches Number Description SW301 Rotary switch SW303 Dip switches SW302 Rotary switch Figure 6.3: Close-up of Rotary Switches and Dip Switches 2013.4 | | Bosch Security Systems, Inc.
  • Page 37: Setting The Address (Id) Of The Camera

    SW303, using the data in the tables below. Note: The value marked * is the default setting. Protocol Off On Bosch OSRD* Off Off Pelco-D/Pelco- Table 6.6: Camera Protocol Setting (No. 1 & 2, Dip Switch SW303)
  • Page 38 Table 6.8: Camera’s RS-485 Termination Setting (No. 5, Dip Switch SW303) Notice! When the RS-485 signal is looped through, make sure that (only) the last device is properly terminated. Improper RS-485 wiring or termination may result in unreliable system operation. 2013.4 | | Bosch Security Systems, Inc.
  • Page 39: On-Screen Display (Osd) Menu

    Basic Navigation and Common Actions Camera operators can operate the camera by two methods: – Use of hot keys [Refer to Bosch Protocol, page 84]. – Use of the OSD Menu displayed on the monitor [Continue to read this chapter].
  • Page 40 Turn the joystick counterclockwise (zoom wide). [KEY] Press the defined key. In Bosch Stop an action; camera switches to protocol: Aux manual mode and pauses temporarily. code; In Pelco protocol: 96 + Preset or ESC button 2013.4 | | Bosch Security Systems, Inc.
  • Page 41 You may need to save settings for one function twice. For example, after {the position or the title of a Preset} is saved at the ‘Sub Menu’, {the status of the Preset Setup} must be saved at the ‘Preset Setup Menu’ again. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 42: Main Menu

    MAIN MENU on your monitor by pressing the keys [95] + [Preset], or by pressing and holding the [Menu] key for 2 seconds. When you use Bosch OSRD protocol with your controller, you can access the MAIN MENU on your monitor by pressing the keys [ON]+[46]+[Enter].
  • Page 43: Editing Titles

    Accesses scan setup. ALARM SETUP Accesses the alarm settings such as: inputs, outputs, and rules. EXIT Exits the menu. 7.2.1 Editing Titles To edit the title of a function (preset, pattern, tour, scan): Bosch Security Systems, Inc. 2013.4 | |...
  • Page 44: Clearing Saved Functions

    [Far] button to return to the previous menu. 7.2.2 Clearing Saved Functions To clear (delete) individual, saved functions: Select a function in any menu (PRESET/TOUR/PATTERN/ SCAN/ALARM). Move the joystick right. Select Clear. If necessary, follow additional prompts. 2013.4 | | Bosch Security Systems, Inc.
  • Page 45: System Setup Menu

    System. It is only for reference; you cannot make changes here. To display the System Information screen: From the MAIN MENU, select SYSTEM SETUP. The submenu SYSTEM SETUP appears. Select INFO.. The screen SYSTEM INFORMATION appears. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 46: Reboot

    Rebooting will recycle power without changing camera settings. To reboot the system: From the MAIN MENU, select SYSTEM SETUP. The submenu SYSTEM SETUP appears. Select REBOOT. The screen REBOOT appears. REBOOT CONTINUE? YES: NEAR NO: FAR 2013.4 | | Bosch Security Systems, Inc.
  • Page 47: Initialize

    ALL: Clear All items saved in the system. – CAM: Clear camera-related settings. – PRESET: Clear all saved presets. (To clear presets individually, refer to Preset Setup, page 68.) – TOUR: Clear saved Tours. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 48: Password

    "0000." To set/enable a password: From the MAIN MENU, select SYSTEM SETUP. The submenu SYSTEM SETUP appears. Select PASSWORD. The screen PASSWORD appears. PASSWORD CURRENT ENABLE CONFIRM 0123456789 -SET/CLEAR -EXIT Select the numbers that comprise the password. 2013.4 | | Bosch Security Systems, Inc.
  • Page 49: Display Setup

    To set up the on-screen display: From the MAIN MENU, select DISPLAY SETUP. The submenu DISPLAY SETUP appears. Select OSD SETUP. The screen OSD SETUP appears. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 50 Title (Label Position) – (Dwell) Time – Zoom (ratio) – (Camera) ID – (Operation) Mode – (PTZ) Angle Note: You can display only selected video or characters in the video. Each element may be configured. 2013.4 | | Bosch Security Systems, Inc.
  • Page 51: Privacy Zone

    The mask will stay in position even with changing pan and tilt angles, and will adjust in size according to the zoom ratio [Tele/ Wide]. Bosch recommends setting the size of the mask to be at least twice the size (height and width) of the object being masked.
  • Page 52: Image Setup

    This menu is for changing displayed image settings. To set up image setup: From the MAIN MENU, select DISPLAY SETUP. The submenu DISPLAY SETUP appears. Select IMAGE SETUP. The screen IMAGE SETUP appears. IMAGE SETUP MIRROR SAVE 2013.4 | | Bosch Security Systems, Inc.
  • Page 53: Motion/Face Detection

    OSD in the Alarm Out action. To set up motion/face detection: From the MAIN MENU, select DISPLAY SETUP. The submenu DISPLAY SETUP appears. Select MOTION/FACE. The screen MOTION/FACE DETECTION appears. MOTION/FACE DETECTION MD/FD SENSITIVITY ALARM Bosch Security Systems, Inc. 2013.4 | |...
  • Page 54: Language

    To select a different display language: From the MAIN MENU, select DISPLAY SETUP. The submenu DISPLAY SETUP appears. Select L ANGUAGE. The screen L ANGUAGE appears. Select the desired language: – English – Chinese – Dutch – French 2013.4 | | Bosch Security Systems, Inc.
  • Page 55: Camera Setup

    30X optical zoom. To set focus/zoom settings: From the MAIN MENU, select CAMERA SETUP. The submenu CAMERA SETUP appears. Select FOCUS/ZOOM. The screen FOCUS/ZOOM SETUP appears. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 56: Wb Setup

    In Manual mode, you can change the R or B gain value to adjust the colors displayed on the monitor. To set white balance settings: 2013.4 | | Bosch Security Systems, Inc.
  • Page 57 In this mode, the white balance is performed at a faster operating speed than ATW. Select the option "R Gain" to set the red gain. Select the appropriate value. Select the option "B Gain." Select the appropriate value. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 58: Ae Setup

    To set auto exposure settings: From the MAIN MENU, select CAMERA SETUP. The submenu CAMERA SETUP appears. Select EXPOSURE. The screen AE SETUP appears. AE SETUP MODE SHUT AGC GAIN AGC MAX BRIGHT SAVE 2013.4 | | Bosch Security Systems, Inc.
  • Page 59: D/N Setup

    The Day & Night filter is automatically switched according to the luminance level. To set day/night: From the MAIN MENU, select CAMERA SETUP. The submenu CAMERA SETUP appears. Select DAY/NIGHT. The screen D/N SETUP appears. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 60: Advanced

    Subjects being shot with dark details due to backlight ,will have the correct brightness levels. Sharpness enhances the picture 2013.4 | | Bosch Security Systems, Inc.
  • Page 61: Wdr/Dnr

    The DNR (Digital Noise Reduction) function creates ’noiseless’ Bosch Security Systems, Inc. 2013.4 | |...
  • Page 62 Select the value "On." Select the option "WDR Level." Set the appropriate level. Select the option "DNR Setup." Select the value "On." Select the option "DNR Level." Set the appropriate level. Save the settings. 2013.4 | | Bosch Security Systems, Inc.
  • Page 63: Dome Motion Setup

    To set these functions: From the MAIN MENU, select DOME MOTION. The submenu DOME MOTION appears. Select GENERAL SETUP. The screen GENERAL SETUP appears. GENERAL SETUP POWER-UP ACT. TURBO SPEED Bosch Security Systems, Inc. 2013.4 | |...
  • Page 64: Motion Setup

    This menu controls camera settings such as proportional pan/ tilt, auto flip, and over tilt. To set these functions: From the MAIN MENU, select DOME MOTION. The submenu DOME MOTION appears. Select MOTION SETUP. The screen MOTION SETUP appears. 2013.4 | | Bosch Security Systems, Inc.
  • Page 65 Select the appropriate value: – Mode 0 – Mode 1 – Mode 2 Each Mode restricts the vertical minimum tilt to prevent horizontal block on the view from the camera’s cover. Save the settings. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 66: Home Action

    DOME MOTION appears. Select HOME ACTION. The screen HOME ACTION SETUP appears. HOME ACTION SETUP ACTION NUMBER TIME MODE SAVE BACK Select the option "Action." Select the appropriate value: – Home – Preset 2013.4 | | Bosch Security Systems, Inc.
  • Page 67: Calibration

    From the MAIN MENU, select DOME MOTION. The submenu DOME MOTION appears. Select CALIBRATION. The screen CALIBRATION SETUP appears. CALIBRATION SETUP AUTO CAL ERROR MSG DISP Bosch Security Systems, Inc. 2013.4 | |...
  • Page 68: Preset Setup

    The camera has a maximum of 210 programmable preset positions. Each of the user-defined presets includes Pan/Tilt/ Zoom. To set up (program) a preset: From the MAIN MENU, select PRESET SETUP. The screen PRESET SETUP appears. PRESET SETUP EDIT 2013.4 | | Bosch Security Systems, Inc.
  • Page 69 Note: Select the option "Clear" to delete the preset. Notice! You can also edit the Preset title. Select the option "Title," then edit the title following the steps in Editing Titles, page 43. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 70: Pattern Setup

    The camera has a maximum of 8 Patterns in Pelco protocol mode, and 2 Patterns in Bosch protocol mode. Each of the user-defined scans includes Pan/Tilt/Zoom. To set up (program) a Pattern: From the MAIN MENU, select PATTERN SETUP.
  • Page 71: Tour Setup

    Tour Setup The camera has a maximum of 8 Tours in Pelco protocol mode, and 2 Tours in Bosch protocol mode. Each tour can have 28 configurable items. Each item can be a pre-defined preset, pattern, and scan in Tour 2-8. (Only Presets (28 maximum) can be inserted in Tour 1.) To set up (program) a tour:...
  • Page 72: Scan Setup

    The speed of Auto Scan can be changed from 1 to 35 degree/sec. To set up (program) an auto scan: From the MAIN MENU, select SCAN SETUP. The screen SCAN SETUP appears. SCAN SETUP EDIT 2013.4 | | Bosch Security Systems, Inc.
  • Page 73 12. Select the option "DTime" to set the dwell time for the scan. 13. Set the desired time (from 3 minute to 60 seconds). 14. Select the option "Direction." 15. Select the appropriate value for the direction of the scan. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 74: Alarm Setup

    This menu controls alarm inputs and outputs. To set alarms: From the MAIN MENU, select ALARM SETUP. The screen ALARM SETUP appears. Select the option "NO.###" to select a preset number. ALARM SETUP PRIORITY ACTION 2013.4 | | Bosch Security Systems, Inc.
  • Page 75 Momentary (On): When an alarm is triggered, the camera will maintain alarm activation continuously, until it is stopped manually (96+preset in Pelco protocol; [Off]+[65]+[Enter] in Bosch protocol). 14. Save the settings. Note: Select the option "Clear" to delete the alarm.
  • Page 76 AUTDOME 4000 Mini en | On-Screen Display (OSD) Menu PTZ Dome Notice! In order to call an action (Preset, Pattern, Tour, or Scan), you must save Preset, Pattern, Tour, or Scan first. 2013.4 | | Bosch Security Systems, Inc.
  • Page 77: Troubleshooting

    - Check the quality and length of video cables, and possible EMC interference. - Check the quality of connectors and potential moisture/corrosion. - If the lens or the dome window is dirty, clean it with a clean cloth. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 78 24VAC (+/- 10%). The communication - Check that the RS-485 cable is between controller and connected correctly. camera (via RS-485 - Check the ID/Protocol/Baud rate/ cable) is not working Termination setting. properly. 2013.4 | | Bosch Security Systems, Inc.
  • Page 79 The image on the screen - Check to see if the camera faces flickers. directly into the sun or a fluorescent lamp. If so, reposition the dome. - Check for flickers on the screen. Bosch Security Systems, Inc. 2013.4 | |...
  • Page 80: Technical Specifications

    On/Off (WDR) Dynamic Noise Reduction 3 DNR (DNR) Privacy Masking 15 zones maximum Maximum Preset Speed 360°/sec Flip Rotate 180° at bottom of tilt Auto Scan 2/8 Auto Scan modes including vector scan 2013.4 | | Bosch Security Systems, Inc.
  • Page 81 4 Normal Dry Contact (Selectable NC/NO) Alarm Output 1 Normal Relays 5VDC/40mA Max (Selectable NC/NO) Control RS-485 baud rate: 2400~38.4Kbps (default: 9600bps) Access Time 0.75 second maximum preset recall time Camera Address / ID Physical 99 Bosch Security Systems, Inc. 2013.4 | |...
  • Page 82 -40 °C to +10 °C (-40 °F to 50 °F) (heater on) Heater (Built-in) On/Off: 0 °C to 10 °C Operating Humidity ~80% relative humidity (RH) Storage Temperature -20 °C to +60 °C (-4 °F to +140 °F) 2013.4 | | Bosch Security Systems, Inc.
  • Page 83: Dimensions

    AUTDOME 4000 Mini Dimensions | en PTZ Dome Dimensions Ø112 (4.41) Ø151.3 (5.96) Ø154 (in.) (6.06) Figure 10.1: Dimensions - Camera 4-Ø4.8 (0.19) (in.) 85.6 (3.37) Figure 10.2: Dimensions - Mounting Holes Bosch Security Systems, Inc. 2013.4 | |...
  • Page 84: Bosch Protocol

    AUTDOME 4000 Mini en | Bosch Protocol PTZ Dome Bosch Protocol The following table lists camera functions in Bosch protocol. Preset Preset Example Number Function Activate Command Example Deactiv Auto Scan 1 On/Off Scan 1 +1+Enter Auto Scan 2 On/Off...
  • Page 85 AUTDOME 4000 Mini Bosch Protocol | en PTZ Dome Preset Preset Example Number Playback B On/Off Pattern 2 (Continuous) +52+Enter Playback B On/Off Pattern 2 (Single) +53+Enter Enters Alarm Alarm Menu Menu +64+Enter Acknowledge Alarm Action Alarms and stopped +65+Enter...
  • Page 86 AUTDOME 4000 Mini en | Bosch Protocol PTZ Dome Preset Preset Example Number Set-recalibrate Run Calibration Home Position +110+Enter Restores all Factory Reset settings +899+Enter * SW Version Number displays 5seconds. *OSD message “D.ZOOM” in D.Z range displays 2 seconds.
  • Page 87: Pelco Protocol

    Run PAN ZERO Preset 34+Prese +Preset Scan Setup Preset 60+Prese +Preset Scan Preset/Scan 61-68 61+Prese +Preset 1+Scan Tour Setup Preset 70+Prese +Preset Tour Preset/Tour 71-78 71+Prese +Preset 1+Tour Pattern Setup Preset 80+Prese +Preset Bosch Security Systems, Inc. 2013.4 | |...
  • Page 88 - To save position of the dome, press the desired preset number and hold the [PRESET] key for 2 seconds.- To go to the MAIN MENU, press and hold the [MENU] key for 2 seconds. 2013.4 | | Bosch Security Systems, Inc.
  • Page 90 Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, PA, 17601 www.boschsecurity.com © Bosch Security Systems, Inc., 2013...

This manual is also suitable for:

Autodome 4000 mini

Table of Contents