Circuit breaker trips

Action:
Remove some of the load, and then press the circuit breaker to reset the load.

UPS operates on battery only

Action:
Save your work.
1.
Power down the load devices connected to the UPS output receptacles.
2.
Remove one or more load devices to reduce the power requirements.
3.
Be sure the UPS configuration matches the utility voltage. Refer to "Selecting the UPS voltage
4.
configuration (on page 22)."

UPS frequently switches between utility and battery power

Action:
Check the input voltage.
1.
Change the power sensitivity adjustment dial
2.
35) setting.
Contact a qualified electrician to verify that the utility power is suitable for the UPS.
3.

UPS does not provide the expected backup time

Action:
If the Output Load Level LED is red or flashing red, remove one or more load devices to reduce the
1.
power requirements.
Power down the UPS
2.
Verify that the batteries are connected.
3.
Allow the UPS batteries to charge for 24 hours.
4.
Initiate a self-test
5.
During extended power outages, save your work, power down the load devices, and then power
6.
down the UPS

UPS emits a slight clicking noise

Action: The UPS is automatically correcting high or low AC voltage on the utility line. No action is
required.

Power LED flashes

Action:
("Powering down the
("Initiating a
self-test" on page 35).
("Powering down the
UPS" on page 36) to conserve battery power.
("Setting the power sensitivity adjustment
UPS" on page 36).
dial" on page
Troubleshooting 43