HP ProLiant ML350 Quickspecs

Generation 5
Hide thumbs Also See for ProLiant ML350:

Quick Links

QuickSpecs
Overview
Front View:
Front View:
Front View:
Front View:
1.
Five removable media bays
2.
Front display panel; includes power button, UID, two USB
2.0 ports, and system status LED's
3.
CD-ROM Drive (Dual-Core models), DVD-ROM Drive
(Quad-Core models)
4.
Eight SFF (2.5") (shown) or six LFF (3.5") SAS or SATA Hot
Plug drive bays
5.
Six expansion slots (three PCI Express, three PCI-X)
6.
Two system fans standard with support for optional
redundant system fans
7.
Support for two Intel® Dual-Core or Quad-Core Xeon®
5000 sequence processors
8.
Eight PC2-5300 FB-DIMM (DDR2 667) memory sockets
9.
Single Hot-Plug power supply standard, optional second
redundant supply for availability
At A Glance
At A Glance
At A Glance
At A Glance
Building on a tradition of excellence, the HP ProLiant family introduces the fifth generation HP ProLiant ML350 server. The HP
ProLiant ML350 G5 server provides Multi-Core performance, enterprise level management, and highly available redundant options
in a modular server form factor. New for this generation is a smaller and quieter chassis, embedded Smart Array E200i Controller
and 5 media bays.
Processors:
Processors
Processors
Processors
Quad-Core and Dual-Core Intel® Xeon® processors for blazing performance; systems support up to 2 processors
1333/1066/667 MHz front side bus (FSB)
DA - 12475
Worldwide — Version 52 — May 13, 2011
HP ProLiant ML350 Generation 5 (G5)
HP ProLiant ML350 Generation 5 (G5)
HP ProLiant ML350 Generation 5 (G5)
HP ProLiant ML350 Generation 5 (G5)
Rear View:
Rear View:
Rear View:
Rear View:
1.
Monitor port
2.
Serial port
3.
USB ports
4.
Integrated Lights-Out 2 (iLO2) port
5.
Network port
6.
PCI Express x4
7.
PCI-X 64/100
8.
PCI-X 64/133
9.
Access to add 2nd redundant power supply
10.
Mouse port
11.
Keyboard port
12.
Power
Page 1
loading

Summary of Contents for HP ProLiant ML350

  • Page 1 At A Glance At A Glance Building on a tradition of excellence, the HP ProLiant family introduces the fifth generation HP ProLiant ML350 server. The HP ProLiant ML350 G5 server provides Multi-Core performance, enterprise level management, and highly available redundant options in a modular server form factor.
  • Page 2 Warranty Warranty: This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of DA - 12475 Worldwide —...
  • Page 3 Mandatory CSR part; 2) Optional CSR parts are also designed for easy replacement but may involve added complexity. Customers may choose to have HP replace Optional CSR parts at no charge. Additional information regarding worldwide limited warranty and technical support is available at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html...
  • Page 4: Standard Features

    QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features NOTE: NOTE: NOTE: NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/4AA0-6362ENW.pdf.
  • Page 5 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features Chipset Chipset Chipset Chipset Intel® 5000Z Chipset NOTE: NOTE: NOTE: NOTE: For more information regarding Intel® chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/.
  • Page 6 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features NOTES: NOTES: NOTES: NOTES: * Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
  • Page 7 NOTE: NOTE: NOTE: Rack models (and rack conversion kit) support: Square or round hole racks 24"- 36" deep, including HP Rack System /E and HP Systems Telco racks with 3rd part option kit from Rack Solutions http://www.racksolutions.com/hp HP Insight management...
  • Page 8 In addition to the previous functional benefits, it also provides a cost-effective disaster recovery for physical and virtual environments that works with HP StorageWorks Continuous Access software for both the Enterprise Virtual Array and the XP storage array allowing application environments to be reactivated in minutes with the touch of a button to a remote location.
  • Page 9 UPS and PDU Power UPS and PDU Power UPS and PDU Power UPS and PDU Power Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page. Under Cord Matrix Cord Matrix Cord Matrix Cord Matrix Power Cords, click on the "HP Power Cord Matrix"...
  • Page 10 Installation of Server into Installation of Server into Installation of Server into Installation of Server into Support for all 2-post Telco racks requires the use of the HP ProLiant ML350 G5 rack kit and an Telco Racks Telco Racks Telco Racks Telco Racks additional option kit from Rack Solutions.
  • Page 11 Whether an SMB, or large global corporation, HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.
  • Page 12 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Models NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models"...
  • Page 13 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Models 458237-xx1 Power Supplies Power Supplies Power Supplies Power Supplies 800-Watt CE-mark compliant Hot-Plug power supply...
  • Page 14: Configuration Information - Factory Integrated Models

    NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
  • Page 15 800W Hot-Plug Power Supply Rack (5U) Form Factor SFF - 2.5" Drives SFF - 2.5" Drives SFF - 2.5" Drives SFF - 2.5" Drives HP ProLiant ML350G5 SFF SAS/SATA Rack CTO Chassis 395569-B21 Includes: Includes: Includes: Includes: Embedded NC373i Multifunction Gigabit Server Adapter...
  • Page 16 Insight Control suite Insight Control suite Insight Control suite Insight Control suite HP Insight Control suite, No Media 1-Server License Factory-Integratable Option 582765-B21 (FIO) including 1 year of 24x7 Technical Support and Updates Step 4: Choose Additional Options for Factory Integration...
  • Page 17: Core Options

    HP PCI-X Expander Kit (2 x 64-bit 100MHz PCI-X slots) 435670-B21 NOTE: NOTE: NOTE: NOTE: The HP PCI-X Expander kit converts a single PCI Express slot (slot 6) into two full height, full length 64-bit 100MHz PCI-X slots. NOTE: NOTE: NOTE: NOTE: The HP PCI-X Expander kit can support a maximum of one (1) HP Smart array, HBA, or SCSI PCI-X adapter.
  • Page 18 NOTE: Please note that SFF 2.5" (small form factor) drives can only be installed on tower or rack models with SFF chassis (models). HP 300GB 6G SAS 10K SFF DP ENT HDD 507127-B21 HP 300GB 3G SAS 10K SFF DP ENT HDD...
  • Page 19 SATA Hot Plug Midline (MDL) Solid State Drives SATA Hot Plug Midline (MDL) Solid State Drives SATA Hot Plug Midline (MDL) Solid State Drives HP 60GB 3G SATA 2.5in MDL 1y Wty SSD 572071-B21 HP 120GB 3G SATA 2.5in MDL 1y Wty SSD 572073-B21 SATA Hot Plug 3.5"...
  • Page 20 Adapter NICs allowed in this server. HP NC373F PCI Express Multifunction Gigabit Server Adapter 394793-B21 HP NC373T PCI Express Multifunction Gigabit Server Adapter 394791-B21 HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter 394795-B21 NOTE: NOTE: NOTE: NOTE: Supported on a full length-full height slot only.
  • Page 21: Additional Options

    Advanced. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service...
  • Page 22 The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service...
  • Page 23 NOTE: NOTE: NOTE: NOTE: The HP x4/x8 PCI Express Bus Expander kit converts 2 x4 PCI Express slots into a single x8 PCI Express slot for high performance x8 PCI Express cards. DA - 12475 Worldwide — Version 52 — May 13, 2011...
  • Page 24 NOTE: Please refer to the "Tape and Disk-Based Backup" table in the Storage section of this document for a list of SAS controllers with tape support. For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect.
  • Page 25 NOTE: NOTE: NOTE: NOTE: 500 GB of Disk Storage. NOTE: NOTE: NOTE: NOTE: Please see the HP RDX Removable Disk Backup System QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_div/13036_div.html D2D Backup D2D Backup D2D Backup D2D Backup HP StorageWorks D2D2502i Backup System...
  • Page 26 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Additional Options HP StorageWorks HP StorageWorks HP StorageWorks HP StorageWorks MSA SAN Storage Arrays MSA SAN Storage Arrays...
  • Page 27 NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13179_div/13179_div.html (Worldwide) NOTE: NOTE: NOTE: NOTE: For additional information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. HP Rack-mountable UPS HP Rack-mountable UPS HP Rack-mountable UPS HP Rack-mountable UPS HP R1500 G2 UPS...
  • Page 28 HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP Monitored Power Distribution Unit: Full Rack Version HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A (NA/JPN) AF503A HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A (NA/JPN) AF504A HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A (NA/JPN)
  • Page 29 NOTE: NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet...
  • Page 30 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Additional Options TFT7600 Rackmount Keyboard Monitor IT AG056A TFT7600 Rackmount Keyboard Monitor SP AG057A TFT7600 Rackmount Keyboard Monitor DEN...
  • Page 31 262587-B21 NOTE: NOTE: NOTE: NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. HP 1x4 Console Switch AF611A PS2 Server Console Cable, 6 ft, 2 pack AF612A...
  • Page 32 Support Plus Support Plus Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech U4524E support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays. (Electronic) Support Plus 24 Support Plus 24 Support Plus 24...
  • Page 33 HP ProLiant ML350 G5 Memory Configuration The HP ProLiant ML350 G5 requires memory interleaving when more than one DIMM is installed. For interleaving, DIMMs must be configured in identical pairs. The system will not boot properly if multiple DIMMs of varying density or type are installed in the system.
  • Page 34 When only bank A is being used, it must be fully populated with dual-rank FBDIMMs. For optimum memory usage, HP recommends all FBDIMMs be the same size with the same HP part number. If different sized FBDIMMs are used, a portion of the installed memory may not be utilized.
  • Page 35: Drive Support

    QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage 1 - 6 6 x 3.5" (LFF) Hot-Plug SAS/SATA hard drive bays 1 - 8 8 x 2.5"...
  • Page 36 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage Quantity Quantity Quantity Quantity Position Position Position Position Supported Supported Supported Supported Supported Supported...
  • Page 37 NOTE: NOTE: NOTE: NOTE: HP Systems Insight Manager should not be used to view the status of SATA hard drives and SATA RAID configurations. SATA Hot Plug 3.5" Entry (ETY) Drives SATA Hot Plug 3.5" Entry (ETY) Drives SATA Hot Plug 3.5" Entry (ETY) Drives SATA Hot Plug 3.5"...
  • Page 38 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage Quantity Quantity Quantity Quantity Position Position Position Position Supported Supported Supported Supported Supported Supported...
  • Page 39 Tape and Disk-Based Backup Tape and Disk-Based Backup Tape and Disk-Based Backup Tape and Disk-Based Backup NOTE: NOTE: NOTE: NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect. Position Position Position Position Controller Controller...
  • Page 40 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage External External External External LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-3 Ultrium 960 LTO-3 Ultrium 920...
  • Page 41 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage MSL2024 MSL4048 MSL8096 MSL6000 HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX HP StorageWorks RDX A,B,C,D USB 2.0 Port...
  • Page 42: Power Specifications

    Maximum Inrush Current duration (milliseconds) NOTE: NOTE: NOTE: NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient www.hp.com/go/hppoweradvisor To drill down to calculators: - Click on: "ProLiant Servers" - Click on the Server of interest. Example: ML350 G5 - Click on: "Power Calculator"...
  • Page 43: Technical Specifications

    Power Specifications Power Specifications Power Specifications NOTE: NOTE: NOTE: NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy- efficient www.hp.com/go/hppoweradvisor - Click on the system of interest. Example: ML350 G5 - Follow the instructions of the next screens.
  • Page 44 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Technical Specifications altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight.
  • Page 45 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Technical Specifications Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Disk Drive and Enclosure...
  • Page 46 Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.