HP ProLiant ML350 Quickspecs
HP ProLiant ML350 Quickspecs

HP ProLiant ML350 Quickspecs

Generation 5
Hide thumbs Also See for ProLiant ML350:

Quick Links

QuickSpecs
Overview
1. Five removable media bays
2. Front display panel; includes power button, UID, two USB 2.0
ports, and system status LED's
3. 48X Max IDE CD-ROM Drive (on standard models)
4. Eight SFF (2.5") (shown) or six LFF (3.5") SAS or SATA Hot
Plug drive bays
5. Six expansion slots (three PCI Express, three PCI-X)
What's New
What's New
What's New
What's New
Intel's new Quad-Core Xeon 5300 series processors with 8MB (2x4MB) L2 cache
Enhanced memory support on Quad-Core models for a maximum of 32 GB of FB-DIMM memory
PCI-X expander cage option kit provides 2 additional full length 64-bit PCI-X slots from a single PCI Express slot
Support for the expanded portfolio of Hot Plug 2.5" (SFF) and 3.5" (LFF) SAS and SATA hard disks.
DA - 12475
Canada — Version 6 — November 14, 2006
HP ProLiant ML350 Generation 5 (G5)
HP ProLiant ML350 Generation 5 (G5)
HP ProLiant ML350 Generation 5 (G5)
HP ProLiant ML350 Generation 5 (G5)
6. Two system fans standard with support for optional redundant
system fans
7. Support for two Intel Dual-Core and Quad-Core Xeon 5000
sequence processors
8. Eight PC2-5300 FB-DIMM (DDR2 667) memory sockets
9. Single Hot-Plug power supply standard, optional second
redundant supply for availability
Page 1
loading

Summary of Contents for HP ProLiant ML350

  • Page 1 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Overview 1. Five removable media bays 6. Two system fans standard with support for optional redundant system fans 2.
  • Page 2 At A Glance At A Glance Building on a tradition of excellence, the HP ProLiant family introduces the fifth generation HP ProLiant ML350 server. The HP ProLiant ML350 G5 server provides Multi-Core performance, enterprise level management, and highly available redundant options in a modular server form factor.
  • Page 3: Standard Features

    QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models"...
  • Page 4 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features Expansion Slots Expansion Slots Expansion Slots Expansion Slots Slot Slot Slot Slot Bus Speed/Connector...
  • Page 5 NOTE: NOTE: NOTE: NOTE: Rack models (and rack conversion kit) support: Square or round hole racks 24"- 35" deep, including HP Rack System /E and HP Systems Telco racks with 3rd part option kit from Rack Solutions http://www.racksolutions.com/hp ProLiant Essentials...
  • Page 6 HP ProLiant ML350 Generation 5 (G5) Standard Features Insight Management Insight Management Agents should be installed on all HP servers to present Agents system instrumentation, health and configuration information into HP Systems Insight Manager and the HP System Management Homepage. The...
  • Page 7 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features protection. The virus throttle feature of the solution slows the propagation of fast spreading virus...
  • Page 8 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Standard Features Remote Management Remote Management Remote Management Remote Management Integrated Lights Out 2 (iLO 2) Standard Management:...
  • Page 9 Installation of Server into Installation of Server into Installation of Server into Installation of Server into Support for all 2-post Telco racks requires the use of the HP ProLiant ML350 G5 rack kit and an Telco Racks Telco Racks Telco Racks Telco Racks additional option kit from Rack Solutions.
  • Page 10 Coverage of UPS Battery is not included, standard warranty terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP qualified rack options installed within the same rack.
  • Page 11 HP's discretion, 24x7 2hr response time incl. HP holidays Deployment Services - HP Installation and Start Up services designed to take time, risk, and worry out of the deployment of ProLiant servers - and free customers IT support staff to focus on what they do best, their business.
  • Page 12 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Models NOTE: NOTE: NOTE: NOTE: For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf.
  • Page 13 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Models Dual-Core Models Dual-Core Models Dual-Core Models Dual-Core Models Fans Fans 2 fans ship standard, 4 fans total supported (does not include power supply...
  • Page 14: Configuration Information - Factory Integrated Models

    NOTE: NOTE: NOTE: NOTE: Standard models of this product offering (see previous section of this document) do not support HP Factory Express Server Configuration Level 1. Step 1: Base Configuration (choose one of the following configurable models) Step 1: Base Configuration (choose one of the following configurable models)
  • Page 15 800W Hot-Plug Power Supply Rack (5U) Form Factor SFF - 2.5" Drives SFF - 2.5" Drives SFF - 2.5" Drives SFF - 2.5" Drives HP ProLiant ML350G5 SFF SAS/SATA Rack CTO Chassis 395569-B21 Includes: Includes: Includes: Includes: Embedded NC373i Multifunction Gigabit Server Adapter with TCP/IP Offload Engine...
  • Page 16 SAS SFF Hot Plug Drives SAS SFF Hot Plug Drives SAS SFF Hot Plug Drives SAS SFF Hot Plug Drives HP 146GB 3G SAS 10K SFF SP HDD 431958-B21 HP 72GB 3G SAS 10K SFF SP HDD 375861-B21 HP 36GB 3G SAS 10K SFF SP HDD...
  • Page 17 435670-B21 NOTE: NOTE: NOTE: NOTE: The HP PCI-X Expander kit converts a single PCI Express slot (slot 6) into two full height, full length 64-bit 100MHz PCI-X slots HP Tower to Rack Conversion Kit - ML350 G5 Kit 412640-B21 NOTE:...
  • Page 18 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Options Rapid Deployment Pack, Single-Server License 267196-B21 NOTE: NOTE: NOTE: NOTE: This license allows 1 server to be deployed and managed via RDP.
  • Page 19 Integrated Lights-Out Select Pack, 1 server License 413119-B21 Featuring: Featuring: Featuring: Featuring: sophisticated remote control and security features for HP BladeSystem servers and ProLiant ML/DL servers in text console environments. NOTE: NOTE: For additional Integrated Light-Out Select Pack License Kits please see the NOTE:...
  • Page 20 SAS SFF Hot Plug Drives SAS SFF Hot Plug Drives SAS SFF Hot Plug Drives SAS SFF Hot Plug Drives HP 146GB 3G SAS 10K SFF SP HDD 431958-B21 HP 72GB 3G SAS 10K SFF SP HDD 375861-B21 HP 36GB 3G SAS 10K SFF SP HDD...
  • Page 21 (Smart Array P400 Controller) http://h18000.www1.hp.com/products/quickspecs/12247_ca/12247_ca.HTML (Smart Array P600 Controller) http://h18000.www1.hp.com/products/quickspecs/12616_ca/12616_ca.HTML (Smart Array P800 Controller) SAS HBA SAS HBA SAS HBA SAS HBA HP 8 Internal Port SAS HBA with RAID 347786-B21 NOTE: NOTE: NOTE: NOTE: RAID 0,1 supported. NOTE: NOTE: NOTE: NOTE: Please see the HBA QuickSpecs for additional information: http://h18004.www1.hp.com/products/quickspecs/12332_ca/12332_ca.html...
  • Page 22 412648-B21 HP NC373F PCI Express Multifunction Gigabit Server Adapter 394793-B21 HP NC373T PCI Express Multifunction Gigabit Server Adapter 394791-B21 HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter 394795-B21 HP NC1020 PCI 1000T Gigabit Server Adapter 353377-B21 NOTE: NOTE:...
  • Page 23 NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional options such as controllers, media, and other related items: http://h18006.www1.hp.com/products/quickspecs/11739_ca/11739_ca.html http://h18006.www1.hp.com/products/quickspecs/12128_ca/12128_ca.html For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect. Internal DAT Drives Internal DAT Drives...
  • Page 24 Tape Libraries Tape Libraries HP StorageWorks MSL2024 1 Ultrium 960 Drive Library AG115A HP StorageWorks MSL2024 1 Ultrium 960 4GB FC Drive Library AG326B HP StorageWorks MSL2024 1 Ultrium 920 Drive Library AH169A HP StorageWorks MSL2024 2 Ultrium 920 Drive Library...
  • Page 25 NOTE: NOTE: NOTE: NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your ProLiant server's System Management Homepage (SMH) software (SmartStart 7.5 or later).
  • Page 26 HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 & 10 and Red 305199-B26 Hat EL 3 & 4 (2 node license cluster kit) HP Serviceguard for Linux A.11.16 for SUSE SLES 9 & 10 and Red Hat EL 3 & 4 307754-B26 (single license version)
  • Page 27 NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and Modular PDUs 1U/0U Modular PDUs 1U/0U Modular PDUs 1U/0U Modular PDUs 1U/0U 9000 series racks). (Up to 32 outlets) HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) 252663-D71 NOTE: NOTE: NOTE: NOTE: 1U/0U mounting NOTE:...
  • Page 28 HP Rack 5000 Series HP Rack 5000 Series HP Rack 5000 Series NOTE: NOTE: NOTE: NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical (Graphite Metallic) Specifications such as height, width, depth, weight, and colour: http://h18000.www1.hp.com/products/quickspecs/12074_ca/12074_ca.HTML NOTE: NOTE:...
  • Page 29 NOTE: NOTE: NOTE: NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. HP 1x 4 USB/PS2 KVM Switch, TT 371301-D71 HP 1x 4 USB/PS2 KVM Switch, RM...
  • Page 30 Support Plus Support Plus Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech U4524E support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays. (Electronic) Support Plus 24 Support Plus 24 Support Plus 24...
  • Page 31 HP ProLiant ML350 G5 Memory Configuration The HP ProLiant ML350 G5 requires memory interleaving when more than one DIMM is installed. For interleaving, DIMMs must be configured in identical pairs. The system will not boot properly if multiple DIMMs of varying density or type are installed in the system.
  • Page 32 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Memory Bank A Bank A Bank A Bank A Bank B Bank B Bank B...
  • Page 33: Drive Support

    QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage 1 - 6 6 x 3.5" (LFF) Hot-Plug SAS/SATA hard drive bays 1 - 8 8 x 2.5"...
  • Page 34 NOTE: NOTE: NOTE: NOTE: HP Systems Insight Manager should not be used to view the status of SATA hard drives and SATA RAID configurations. Hot Plug SFF SAS 2.5" Drives Hot Plug SFF SAS 2.5" Drives Hot Plug SFF SAS 2.5" Drives Hot Plug SFF SAS 2.5"...
  • Page 35 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Storage External Storage External Storage External Storage External Storage Quantity Quantity Position Position Quantity Quantity...
  • Page 36 DAT 72 DLT VS160 SDLT 600 HP StorageWorks Tape HP StorageWorks Tape HP StorageWorks Tape HP StorageWorks Tape HP 8 Internal Port SAS HBA with RAID 0/1 347786-B21 Drives, SAS Internal Drives, SAS Internal Drives, SAS Internal Drives, SAS Internal NOTE:...
  • Page 37 HP ProLiant ML350 Generation 5 (G5) Storage HP StorageWorks SAS HP StorageWorks SAS HP StorageWorks SAS HP StorageWorks SAS External HP 8 Internal Port SAS HBA with RAID 0/1 347786-B21 Rack-Mount Tape Drive Rack-Mount Tape Drive Rack-Mount Tape Drive Rack-Mount Tape Drive NOTE:...
  • Page 38: Power Specifications

    QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Power Specifications Part Number Part Number Part Number Part Number 380622-001 Spare Kit Spare Kit...
  • Page 39: Technical Specifications

    QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Technical Specifications System Unit - Tower System Unit - Tower System Unit - Tower System Unit - Tower...
  • Page 40 QuickSpecs HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) HP ProLiant ML350 Generation 5 (G5) Technical Specifications System Unit - Rack System Unit - Rack System Unit - Rack System Unit - Rack...
  • Page 41 Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

This manual is also suitable for:

Proliant ml350 generation 5