Fujitsu PRIMEQUEST 2000 Series General Description Manual

Primequest 2000 series server
Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents
FUJITSU Server
PRIMEQUEST 2000 Series

General Description

C122-B025-02EN
Table of Contents
loading

Summary of Contents for Fujitsu PRIMEQUEST 2000 Series

  • Page 1: General Description

    FUJITSU Server PRIMEQUEST 2000 Series General Description C122-B025-02EN...
  • Page 2 Preface Preface This manual describes the functions and features of the PRIMEQUEST 2000 series. The manual is intended for system administrators. For details on the regulatory compliance statements and safety precautions, see the PRIMEQUEST 2000 Series Safety and Regulatory Information (C122-E171XA).
  • Page 3 Manual. Appendix F Tree Structure of the MIB provided with the PRIMEQUEST 2000 series Appendix F provides a link to Appendix H Tree Structure of the MIB Provided with the PRIMEQUEST 2000 Series in the PRIMEQUEST 2000 Series Administration Manual.
  • Page 4: Revision History

    Preface Revision History Edition Date Revised location (type) (*1) Description 2014-02-18 2014-04-10 CHAPTER 1 Updated Product Overview CHAPTER 2 Updated Hardware Configuration CHAPTER 3 Updated Software Configuration CHAPTER 5 Updated Partitioning *1: Chapter, section, and item numbers in the "Revised location" column refer to those in the latest edition of the document.
  • Page 5: Safety Precautions

    Similarly, one space line is inserted before and after the alert statement. Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu. Customers must not perform these tasks under any circumstances.
  • Page 6 Preface Warning label location (the main cabinet top) C122-B025-02EN...
  • Page 7 Preface Warning label location (the main cabinet left) Warning label location (PCI_Box) C122-B025-02EN...
  • Page 8: About This Product

    For stable operation of the PRIMEQUEST 2000 series server, use only a Fujitsu-certified optional product as an added option. Note that the PRIMEQUEST 2000 series server is not guaranteed to operate with any optional product not certified by Fujitsu. Exportation/release of this product Exportation/release of this product may require necessary procedures in accordance with the regulations of the Foreign Exchange and Foreign Trade Control Law of Japan and/or US export control laws.
  • Page 9: Support And Service

    Be sure to keep this manual in a safe and convenient location for quick reference. Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage. Be sure to use the product according to the instructions in this manual.
  • Page 10 Includes the specifications of and the installation location C122-H007EN Hardware Installation Manual requirements for the PRIMEQUEST 2000 series. PRIMEQUEST 2000 Series Describes how to set up the PRIMEQUEST 2000 series C122-E174EN Installation Manual server, including the steps for installation preparation, initialization, and software installation.
  • Page 11 Defines the PRIMEQUEST 2000 series related terms and C122-E179EN Glossary abbreviations. Related manuals The following manuals relate to the PRIMEQUEST 2000 series. You can access these manuals at the following site: http://manuals.ts.fujitsu.com/ Contact your sales representative for inquiries about the ServerView manuals. Title...
  • Page 12 None Refer to the manual from the second DVD for ServerView Suite which you can purchase optionally or from the following URL: The Fujitsu Technology Solutions manuals server http://manuals.ts.fujitsu.com/ MegaRAID SAS Device Provides technical information on using array controllers. None...
  • Page 13: Command Syntax

    Font or symbols Meaning Example italics Title of a manual that you should refer to See the PRIMEQUEST 2000 Series Installation Manual (C122-E174EN). Window names as well as the names of Click the [OK] button. buttons, tabs, and drop-down menus in windows are enclosed in brackets.
  • Page 14 The PDF file of this manual is intended for display using Adobe® Reader® in single page viewing mode at 100% zoom. This manual shall not be reproduced or copied without the permission of Fujitsu Limited. Copyright 2014 FUJITSU LIMITED C122-B025-02EN...
  • Page 15: Table Of Contents

    Preface Contents Preface ..........................................i CHAPTER 1 Product Overview ................................. 1 Introduction of the PRIMEQUEST 2000 series..........................1 1.1.1 Features ....................................1 Product Lineup ....................................2 PRIMEQUEST 2000 series configuration ............................ 4 1.3.1 Hardware configuration ................................5 1.3.2 Hardware specifications ................................ 10 1.3.3...
  • Page 16 Firmware ....................................23 1.5.2 Operating system and virtualization software ........................24 1.5.3 Server management software ............................... 24 1.5.4 Fujitsu middleware products ..............................27 1.5.5 Clustering ....................................27 CHAPTER 2 Hardware Configuration ..............................28 Components ....................................28 Base cabinet ....................................30 CPU ......................................
  • Page 17 Bundled software ..................................62 Supplied Drivers ..................................63 Firmware ..................................... 63 Operations Management Software............................63 CHAPTER 4 Functions provided by the PRIMEQUEST 2000 series ....................64 Basic Architecture ..................................64 Management with MMB ................................64 4.2.1 MMB functions ..................................64 4.2.2...
  • Page 18 Preface 4.11.1 sadump firmware ................................74 4.12 Memory Dump Function (Linux) ..............................74 4.13 Memory Dump Function (Windows) ............................75 CHAPTER 5 Partitioning ..................................76 Partitioning Function ................................... 76 Physical Partitioning (PPAR) ..............................76 5.2.1 Partition granularity ................................77 5.2.2 Partition Configuration rule ..............................
  • Page 19 Appendix D Component Mounting Conditions ............................96 Appendix E Cable (Specifications ................................97 Appendix F Tree Structure of the MIB provided with the PRIMEQUEST 2000 series ................98 Appendix G Linkage functions and Services ..............................99 Linkage with Systemwalker Centric Manager ........................... 99 Remote Customer Support System (REMCS) .........................
  • Page 20 FIGURE 1.5 Hardware configuration image (PRIMEQUEST 2800E) ....................7 FIGURE 1.6 Hardware configuration image (PRIMEQUEST 2800B) ....................9 FIGURE 1.7 Configuration diagram of the PRIMEQUEST 2000 series operation management ............. 25 FIGURE 1.8 SVIM setup flow ................................26 FIGURE 2.1 PRIMEQUEST 2400E/2800E front view ........................30 FIGURE 2.2 PRIMEQUEST 2400E/2800E rear view .........................
  • Page 21 Preface FIGURE 4.4 REMCS (Automatic report function) ..........................68 FIGURE 4.5 Diagram of time synchronization (of three 3 NTP servers) .................... 71 FIGURE 4.6 Flow of Proactive monitoring ............................73 FIGURE 4.7 Sadump conceptual diagram ............................74 FIGURE 5.1 Conceptual diagram of the partitioning (PRIMEQUEST 2400E) ................... 76 FIGURE 5.2 Conceptual diagram of the partitioning (PRIMEQUEST 2800E) ...................
  • Page 22 Preface Tables TABLE 1.1 Hardware specifications..............................10 TABLE 1.2 Hardware RAID Level ................................. 15 TABLE 1.3 VT ......................................16 TABLE 1.4 PXE boot support (external) ............................... 18 TABLE 1.5 iSCSI boot ................................... 19 TABLE 1.6 iSCSI connections................................19 TABLE 1.7 FCoE boot ................................... 20 TABLE 1.8 FCoE connections ................................
  • Page 23 Preface TABLE 5.4 Partition configuration rule (component) ..........................78 TABLE 5.5 Partition granularity of each component that makes up the partition (Extended Partitioning) ......... 78 TABLE 5.6 Minimum and maximum configuration of Extended Partitioning ..................79 TABLE 6.1 System disk redundancy ..............................82 TABLE 6.2 Redundancy of external storage ............................
  • Page 24: Chapter 1 Product Overview

    PRIMEQUEST 2000 series. Introduction of the PRIMEQUEST 2000 series PRIMEQUEST 2000 series is a server with highest level scalability, availability and operability by considering the newest Intel architecture as its basis. In particular, PRIMEQUEST 2000 incorporates server integration and power-saving technologies, thereby contributing to cost savings and green ICT systems.
  • Page 25: Product Lineup

    Precision control of cooling fan rotation speed Support of Power Saving function Compliance with RoHS regulation (2011/65/EU) Product Lineup The PRIMEQUEST 2000 series includes the following models. PRIMEQUEST 2400E: 4 sockets, Enterprise model PRIMEQUEST 2800E: 8 sockets, Enterprise model PRIMEQUEST 2800B: 8 sockets, Business model The external view is shown below.
  • Page 26: Figure 1.2 External Overview Of 2800B

    CHAPTER 1 Product Overview 1.2 Product Lineup FIGURE 1.2 External Overview of 2800B C122-B025-02EN...
  • Page 27: Primequest 2000 Series Configuration

    CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration PRIMEQUEST 2000 series configuration The following figure shows a conceptual diagram of the configuration of the PRIMEQUEST 2000 series. FIGURE 1.3 Configuration conceptual diagram Remarks IOU_10GbE and IOU_1GbE are collectively referred as IO units (IOU)
  • Page 28: Hardware Configuration

    CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration 1.3.1 Hardware configuration Features of PRIMEQUEST 2400E The features of the PRIMEQUEST 2400E are listed below. Up to two CPUs can be mounted to each SB Up to two SBs can be mounted...
  • Page 29 CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration C122-B025-02EN...
  • Page 30: Figure 1.5 Hardware Configuration Image (Primequest 2800E)

    CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration Features of the PRIMEQUEST 2800E Features of the PRIMEQUEST 2800E are as below. Up to 2 CPUs can be mounted to each SB Up to 4 SBs can be mounted Up to 4 HDDs can be mounted to each SB...
  • Page 31 CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration C122-B025-02EN...
  • Page 32: Figure 1.6 Hardware Configuration Image (Primequest 2800B)

    CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration Features of the PRIMEQUEST 2800B Features of the PRIMEQUEST 2800B are as below. Up to 2 CPUs can be mounted to each SB Up to 4 SBs can be mounted Up to eight sockets SMPs...
  • Page 33: Hardware Specifications

    CHAPTER 1 Product Overview 1.3 PRIMEQUEST 2000 series configuration 1.3.2 Hardware specifications The hardware specifications of the PRIMEQUEST 2000 series are listed in the table below. TABLE 1.1 Hardware specifications PRIMEQUEST 2400E 2800E 2800B Number of mounted SBs Number of mounted IOUs...
  • Page 34: Partition Management

    Multiple production system can be operated on a PRIMEQUEST 2000 by installing different OS and applications in each partition. The configuration of a partition of the PRIMEQUEST 2000 series can be changed by static configuration control function (*1), and by dynamic configuration control function (*2).
  • Page 35: Hardware Technologies

    Via the CLI where the management terminal is connected to the MMB serial port Hardware technologies This section describes the main functions provided in the PRIMEQUEST 2000 series. Technology that attains high efficiency, high scalability (expandability) Intel ® Xeon ® processor E7 v2 product family...
  • Page 36: Cpu

    The default value is “enabled” 1.4.2 QuickPath Interconnect (QPI) The PRIMEQUEST 2000 series uses a high-speed system bus called Intel ® Quick Path Interconnect (QPI) to communication within the SB and between CPUs. The resource can be increased by connecting peer CPUs by the QPI.
  • Page 37: Memory Mirror Functions

    Capacity Keep Mode: The memory capacity is maintained by cancelling the memory duplication either partially or in full. For the details on the Memory Mirror function, see ‘3.2.5 Memory Mirror’ in “PRIMEQUEST 2000 Series Administration Manual” (C122-E175EN). 1.4.5 Memory Sparing Function The PRIMEQUEST 2000 series is provided with a Memory Sparing function.
  • Page 38: Pci Hot Plug Function

    1.4.8 PCI Hot Plug Function All PCI Express slots in the PCI_Box of the PRIMEQUEST 2000 series support the PCI hot plug function. This function is a technology that enables extraction or insertion of a PCI card during system operation.
  • Page 39: Extended Partitioning

    The Flexible I/O can configure a physical partition by combining any SB and IOU irrespective of the mounting location. The PRIMEQUEST 2400E/2800E supports Flexible I/O. 1.4.15 Virtual Support Virtualization Technology (VT) Function PRIMEQUEST 2000 series supports the Virtualization Technology (VT) listed in the table below. TABLE 1.3 VT VM Support Components...
  • Page 40: Management Board (Mmb)

    At least one MMB is required for operating the system in the PRIMEQUEST 2000 series. One more MMB can duplicate the MMB in PRIMEQUEST 2400E and 2800E; even if one of the MMBs fail, the process can be continued with the other MMB.
  • Page 41: Preboot Execution Environment (Pxe)

    1.4 Hardware technologies 1.4.18 Preboot eXecution Environment (PXE) The PRIMEQUEST 2000 series supports the PXE boot through LAN port on the IOU. It does not support PXE boot functions through other LAN ports or the PCI Express card. The PXE enables remote management operations, such as system startup and installation and updating of the operating system.
  • Page 42: Iscsi Boot And Iscsi Connection

    CHAPTER 1 Product Overview 1.4 Hardware technologies 1.4.19 iSCSI boot and iSCSI connection The PRIMEQUEST 2000 series supports iSCSI boot and iSCSI connections. TABLE 1.5 iSCSI boot iSCSI boot Component Port Legacy IPv4 IPv6 IPv4 IPv6 User port 1000Base-T (Management...
  • Page 43: Fcoe Boot And Fcoe Connection

    CHAPTER 1 Product Overview 1.4 Hardware technologies 1.4.20 FCoE boot and FCoE connection PRIMEQUEST 2000 series supports FCoE boot and FCoE connections. TABLE 1.7 FCoE boot FCoE boot Component Port Legacy IPv4/IPv6 IPv4/IPv6 User port 1000Base-T (Management LAN) REMCS port...
  • Page 44: Wake On Lan (Wol)

    The memory dump can be acquired by executing sadump when error occurs irrespective of the status of the RHEL that is operating in the PRIMEQUEST 2000 series. Then, investigation of the cause of error and support becomes possible thereby receiving a high degree of support.
  • Page 45: Optimal Fan Control Cooling (Optimization Of Rotation Per Minute Of Fans)

    1.4.27 Optimal Power Allocation (Optimization of the number of operation power sources) The PRIMEQUEST 2000 series supports Optimal Power Allocation as one of the energy saving functions. The following operations are performed in Optimal Power Allocation. Optimization of the number of operating PSUs Changing the number of operating PSUs based on the configuration of the device.
  • Page 46: Power Saving

    *1: SVAS does not monitor SAS RAID controller card. Since BMC firmware and MMB firmware monitor SAS RAID controller cards, monitoring SAS RAID controller cards can be done without installing SVAS. Software technologies The PRIMEQUEST 2000 series uses the following types of software to increase reliability, availability, and operability. Firmware...
  • Page 47: Operating System And Virtualization Software

    Linux PRIMEQUEST 2000 series supports Linux operating systems such as Red Hat Enterprise Linux and SUSE Linux Enterprise Server. PRIMEQUEST 2000 series also supports KVM adopted in Red Hat Enterprise Linux and SUSE Linux Enterprise Server. VMware PRIMEQUEST 2000 series supports VMware vSphere 5 as a virtualization platform.
  • Page 48: Figure 1.7 Configuration Diagram Of The Primequest 2000 Series Operation Management

    ServerView Agent (SV Agent) ServerView RAID Manager (SV RAID) ServerView Mission Critical Option (SVmco) The SVS manages the PRIMEQUEST 2000 series in the following configuration. FIGURE 1.7 Configuration diagram of the PRIMEQUEST 2000 series operation management ServerView Installation Manager (SVIM) SVIM allows the user to easily perform the setup operations, including the OS installation during the initial installation or reconfiguration of a server.
  • Page 49: Figure 1.8 Svim Setup Flow

    CHAPTER 1 Product Overview 1.5 Software technologies FIGURE 1.8 SVIM setup flow Item Description Automatic HDD You can configure RAID using configuration tool called RAID configuration WebBIOS. This tool is started after power-on and start of OS. SVIM can simplify setup for a RAID. You only need to enter information such as the RAID type, combination of HDDs, and spares, even if without having the knowledge on how to operate the RAID configuration tool.
  • Page 50: Fujitsu Middleware Products

    As long as virtualization software environment provides the function that is compatible with the physical hardware environment, Fujitsu middleware can operate on a guest OS. Operation on virtual software might not be assured depending on the middleware or operation pattern.
  • Page 51: Chapter 2 Hardware Configuration

    CHAPTER 2 Hardware Configuration 2.1 Components CHAPTER 2 Hardware Configuration This section describes the PRIMEQUEST 2000 series hardware configuration, system specification and each component specification. Components The table below lists the hardware components. Remarks The hierarchy in the component column represents an inclusive relationship. Components with hyphen (-) are included in the higher level component.
  • Page 52 CHAPTER 2 Hardware Configuration 2.1 Components TABLE 2.1 Maximum installation number of component list (continued) Maximum number mounted Redundancy Display Component Granularity PRIMEQUEST configuration format 2400E 2800E 2800B Per SB - FBU - HDDBP HDDBP - HDD/ SSD HDD#0, Possible by option HDD#3, etc.
  • Page 53: Base Cabinet

    CHAPTER 2 Hardware Configuration 2.2 Base cabinet Base cabinet An overview of the PRIMEQUEST 2000 series device is shown below. FIGURE 2.1 PRIMEQUEST 2400E/2800E front view FIGURE 2.2 PRIMEQUEST 2400E/2800E rear view FIGURE 2.3 PRIMEQUEST 2400E/2800E top view C122-B025-02EN...
  • Page 54: Figure 2.4 Primequest 2400E/2800E Right View

    CHAPTER 2 Hardware Configuration 2.2 Base cabinet FIGURE 2.4 PRIMEQUEST 2400E/2800E right view FIGURE 2.5 PRIMEQUEST 2400E/2800E perspective view FIGURE 2.6 PRIMEQUEST 2800B front view C122-B025-02EN...
  • Page 55: Figure 2.7 Primequest 2800B Rear View

    CHAPTER 2 Hardware Configuration 2.2 Base cabinet FIGURE 2.7 PRIMEQUEST 2800B rear view FIGURE 2.8 PRIMEQUEST 2800B top view FIGURE 2.9 PRIMEQUEST 2800B right view C122-B025-02EN...
  • Page 56: Cpu

    2.3 CPU FIGURE 2.10 PRIMEQUEST 2800B perspective view This section describes the CPU adopted in the PRIMEQUEST 2000 series. 2.3.1 Support CPU list Intel ® Xeon ® processor E7-8800 v2 product family and Intel ® Xeon ® processor E7-4800 v2 product family are installed in the PRIMEQUEST 2000 series.
  • Page 57: Supported Dimm

    ‘1.3.2 Hardware specifications’ 2.4.2 DIMM slot locations For details on the DIMM slot location on SB, see ‘G.2 DIMM’ of “PRIMEQUEST 2000 Series Administration Manual”. 2.4.3 DIMM installation group The DIMM mounting group differs according to the Memory Operation Mode in the PRIMEQUEST 2000 series.
  • Page 58: Figure 2.11 Sb External View

    CHAPTER 2 Hardware Configuration 2.5 SB (System board) FIGURE 2.11 SB External view Description Top view Front view Front perspective view Right lateral view C122-B025-02EN...
  • Page 59: Usb

    CHAPTER 2 Hardware Configuration 2.5 SB (System board) The outline of each component making up the SB is shown follows. Up to two Intel ® Xeon ® processors E7 v2 product family can be mounted. Three system buses called Intel ® QuickPath Interconnect (QPI) are output from each CPU. Large scale configuration (SMP) with up to 8CPUs can be made, by connecting to other CPUs.
  • Page 60: Vga

    External dimensions (mm) (remove protrusions) Width 192.6 x Depth 269.2 x Height 31.4 Weight 1.2 kg In each model of the PRIMEQUEST 2000 series, a redundant configuration can be established by mounting two MMBs. The following figure shows overviews of the MMB. C122-B025-02EN...
  • Page 61: Mmb Serial Interface

    MMB through a CLI. For details on accessing the MMB through the serial interface, see ‘3.3.1 Connecting the MMB console PC’ in the PRIMEQUEST 2000 Series Installation Manual (C122-E174EN). 2.6.3 MMB LAN interface The MMB has a total of three types of ports, namely, the GbE LAN port (for management), the CE port (for maintenance) and the REMCS port.
  • Page 62: External Ports Of The Mmb

    CE port (MMB [LOCAL] port) The CE port is used by a field engineer to install or repair the PRIMEQUEST 2000 series (server). It is a LAN port for connecting to the terminal of the field engineer (FST: Field Support Tool).
  • Page 63: Figure 2.14 External View Of Iou_1Gbe

    CHAPTER 2 Hardware Configuration 2.7 IOU (IO unit) Specifications Item GbE LAN Controller (IOU_1GbE) GbE LAN Controller (IOU_10GbE) Jumbo frame Supported Supported VMDq Supported Supported SR-IOV Supported Supported Energy Efficient Ethernet Supported Not Supported Supported Supported iSCSI boot Supported Supported Supported Supported Network...
  • Page 64: Iou Card Slot

    Front view Front perspective view Right view IOU (IOU_1GbE/IOU_10GbE) has an LED. For details, see ‘F.1.5 IOU’ of the “PRIMEQUEST 2000 Series Administration Manual” (C122-E175EN). 2.7.2 IOU card slot The PCI Express slot of the IOU does not have an LED.
  • Page 65: Du Specifications

    CHAPTER 2 Hardware Configuration 2.8 DU (Disk unit) TABLE 2.7 Connection of IOU with DU Connection destination HDD Connection source Destination For two HDD per For four HDD per SAS RAID controller card SAS RAID controller card IOU#0 DU#0-PCI Slot#0 HDD#2, #3 in DU#0 DU#0 HDD#0,#1,#2,#3 IOU#1...
  • Page 66: Figure 2.17 External View Of The Du

    CHAPTER 2 Hardware Configuration 2.8 DU (Disk unit) Weight (kg) (without HDD/SSD) 2.9 kg *1: Hot plug of HDD is enabled only when HDD is duplicated by the RAID. *2: Usable RAID levels are dependent on the number of SAS RAID controller cards and the number of HDDs mounted in the DU.
  • Page 67: Internal Storage Device

    This section describes the internal HDD and internal SSD (solid state drive) supported by the PRIMEQUEST 2000 series. Component that can include internal HDD/SSD in the PRIMEQUEST 2000 series is as below. HDD bays in the SB (Except for PRIMEQUEST 2800B) For number of slot built-in SB and DU, see TABLE 1.1 Hardware...
  • Page 68: Internal Ssd

    CHAPTER 2 Hardware Configuration 2.10 OPL (Operator panel) 2.9.2 Internal SSD The SSD capacity in maximum configuration and the maximum LUN capacity in a RAID configuration are listed in the table below. TABLE 2.11 The SSD capacity in maximum configuration and the maximum LUN capacity in a RAID configuration Maximum PRIMEQUEST capacity Maximum LUN...
  • Page 69: Figure 2.18 External View Of Opl

    CHAPTER 2 Hardware Configuration 2.10 OPL (Operator panel) FIGURE 2.18 External view of OPL Description Top view Front view Front side perspective view Right lateral view C122-B025-02EN...
  • Page 70: Opl Specifications

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box 2.10.1 OPL specifications The specification of the OPL is listed in the table below. TABLE 2.12 OPL specifications Item Specifications System Power, System Alarm, System Location, CSS Dimension (mm) (remove protrusions) Width 22 x Depth 101 x Height 112 Weight (kg) 0.06 kg 2.11 PCI_Box...
  • Page 71: Figure 2.19 Pci_Box Conceptual Diagram

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box FIGURE 2.19 PCI_Box conceptual diagram C122-B025-02EN...
  • Page 72: Pci_Box Mounting Structural Diagram

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box 2.11.3 PCI_Box mounting structural diagram The following figures show structural views of the PCI_Box cabinet. FIGURE 2.20 Orthographic view of the PCI_Box cabinet Description Top view Front view Right view Rear view C122-B025-02EN...
  • Page 73: Pci_Box Block Diagram

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box FIGURE 2.21 Perspective views of the PCI_Box cabinet 2.11.4 PCI_Box block diagram PCI_Box block diagram is shown below. FIGURE 2.22 PCI_Box block diagram C122-B025-02EN...
  • Page 74: Pci_Box Component List

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box 2.11.5 PCI_Box component list PCI_Box component list is shown below. TABLE 2.14 PCI_Box components Component Unit Display format Redundancy PCI_Box PCI_Box#0, #1, #2, #3 Possible by option IO_PSU 2/PCI _Box IO_PSU#0, IO_PSU#1 Possible by option IO_FAN 2/PCI _Box IO_FAN#0, IO_FAN#1...
  • Page 75: Figure 2.24 Pci_Box Connection Diagram (Maximum Configuration) For Mounted Four Iou_10Gbes

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box FIGURE 2.24 PCI_Box connection diagram (maximum configuration) for mounted four IOU_10GbEs C122-B025-02EN...
  • Page 76: Pci _Box Connection Conditions

    This section describes the PCI_Box connection conditions of the PRIMEQUEST 2000 series. Remarks Limitation for PCI Box connections is as follows: Different PRIMEQUEST 2000 series cabinet cannot be connected to the same PCI_Box (PCI_Box sharing). Connection examples are shown below. Straight connections (permitted)
  • Page 77: Figure 2.27 Connection To Different Pci_Boxes Pattern 1 (Permitted)

    CHAPTER 2 Hardware Configuration 2.11 PCI_Box FIGURE 2.27 Connection to different PCI_Boxes pattern 1 (permitted) FIGURE 2.28 Connection to different PCI_Boxes pattern 2 (permitted) FIGURE 2.29 Connection from IOU_1GbE and IOU_10GbE (permitted) C122-B025-02EN...
  • Page 78: Pci_Box Number

    2.12 PCI Express slot The IOU is provided as the PCI Express slot in the PRIMEQUEST 2000 series. It is a shared component of the PRIMEQUEST 2000 series. The following IOUs depend on the available PCI Express card and the bandwidth type.
  • Page 79: Pci Express Cassette

    2.14 Power Supply Unit (PSU) PSU is a power supply unit to convert the AC input to DC 12V. In the PRIMEQUEST 2000 series, common PSU/Fan unit bays are provided in six places at the rear of the cabinet. In the PRIMEQUEST 2000 series, no redundancy of PSU, namely single power feed is considered as the standard.
  • Page 80: Psu_P Specifications

    CHAPTER 2 Hardware Configuration 2.14 Power Supply Unit (PSU) FIGURE 2.31 External view of the PSU Number Description Front Front perspective Right lateral Remarks Different PSUs (PSU_P, PSU_S) cannot be mounted in the same cabinet. For the configuration of the PSU, see ‘4.5.1 PSU Configuration’.
  • Page 81: Psu_S Specifications

    CHAPTER 2 Hardware Configuration 2.14 Power Supply Unit (PSU) TABLE 2.19 PSU_P Specifications Item Specifications 1 φ AC 100 V-120V, 1 φAC200 V-240 V Input voltage Output voltage DC12V Output power AC100 V (*1) 1165 W AC200 V 2685 W Width 137...
  • Page 82: Dual Power Feed Configuration

    Mounting Conditions’ of the “PRIMEQUEST 2000 Series Administration Manual” (C122-E177EN). 2.15 Fan (Cooling mechanism) The PRIMEQUEST 2000 series uses FANU and fan built in the PSU for cooling the main system. Cooling is divided in Group 0 and Group 1.
  • Page 83 CHAPTER 2 Hardware Configuration 2.16 FCoE C122-B025-02EN...
  • Page 84: Table 2.24 Fcoe Connection (Internal)

    CHAPTER 2 Hardware Configuration 2.16 FCoE TABLE 2.24 FCoE Connection (internal) FCoE Connection FCoE boot Component Port Legacy Legacy IPv4/Pv6 IPv4/IPv6 IPv4/IPv6 IPv4/IPv6 SB, MMB Private LAN port 100 Base-TX Not supported Not supported Not supported Not supported Remote KVMS 100 Base -T Not supported Not supported...
  • Page 85: Chapter 3 Software Configuration

    This chapter describes the supported operating systems, bundled software, firmware, and operations management software of the PRIMEQUEST 2000 series. Bundled electronic media Electronic media are bundled with the PRIMEQUEST 2000 series. The operations management software that includes the bundled software, bundled drivers and installation tools are recorded in electronic media.
  • Page 86: Supplied Drivers

    ‘1.5.1 Firmware’. Operations Management Software PRIMEQUEST 2000 series is linked to the operation management products of Fujitsu Limited (Enterprise Server Management (ESM)) (*1). It provides a function for linking with the major operations management software (IBM Tivoli, HP SIM) of other companies.
  • Page 87: Chapter 4 Functions Provided By The Primequest 2000 Series

    This chapter describes the functions and architecture of the system provided by the PRIMEQUEST 2000 series. Basic Architecture The following figure shows the basic architecture of the PRIMEQUEST 2000 series for hardware system management. FIGURE 4.1 Basic architecture Management with MMB This section provides an overview of the MMB management function and its operating environment.
  • Page 88: Mmb Firmware

    CHAPTER 4 Functions provided by the PRIMEQUEST 2000 series 4.2 Management with MMB Also, it controls the entire system in linkage with the PRIMEQUEST 2000 series, BIOS firmware and the BMC firmware. It provides the interface to the higher level operations management software through the SNMP and IPM.
  • Page 89: Hardware Monitoring And Configuration Display

    FIGURE 4.2 [System Status] window (example of configuration display screen) shows an example of the configuration of the PRIMEQUEST 2000 series. At the same time, the configuration information indicates the component status (e.g., normal, abnormal). If the state of the component is abnormal, the system administrator or a field engineer may have to take corrective action.
  • Page 90: Partition Settings And Configuration Display

    CHAPTER 4 Functions provided by the PRIMEQUEST 2000 series 4.3 REMCS (automatic notification function) For the details of the REMCS Agent, see “PRIMEQUEST 2000 series REMCS Service Manual” (C122- E180). 4.2.5 Partition settings and configuration display It is a function that displays the settings and configuration of partition. Settings and configuration display of partition is used for determining the unit of management and controlling and distributing the hardware resources that are installed.
  • Page 91: Saving And Restoring System Settings Information

    FIGURE 4.4 REMCS (Automatic report function) Saving and Restoring System Settings Information The PRIMEQUEST 2000 series stores the system information as shown below. Therefore, even if there is failure in any one of the components, another component can take over the information from the failed component.
  • Page 92: Power Consumption Monitoring

    4.5.3 Optimal Power Allocation The PRIMEQUEST 2000 series is equipped with the optimal power allocation function that varies the number of active power supply units according to the system configuration. Optimal Power Allocation keeps the power supply highly efficient.
  • Page 93: Scheduled Operations

    Uninterruptible Power System (UPS) is an external battery unit. With a UPS connected, the device can be prepared for a power failure or sudden power supply fluctuation. The UPS of the PRIMEQUEST 2000 series is a SMART UPS. Shut down is instructed from PowerChute by the LAN connection.
  • Page 94: Ntp Client

    BMC time synchronizes with the MMB time. 4.6.2 NTP client In PRIMEQUEST 2000 series, the MMB becomes an NTP client to synchronize the time with an external NTP server. When NTP servers in an external network are not connected to the PRIMEQUEST 2000 series, it is recommended to use an NTP server device that uses an external clock.
  • Page 95 Overview of proactive monitoring Proactive monitoring operations Two types of errors detected by hardware The PRIMEQUEST 2000 series detects the following two types of errors, depending on the hardware. Uncorrectable Error ( UE) Correctable Error ( CE) If an uncorrectable error occurs, the hardware stops all the partitions affected by the error, disconnects the component on which the error occurs, and tries a restart.
  • Page 96: Video Redirection

    REMCS (notification (When REMCS connection is specified, the MMB sends a notification.) System Event Log output The transmission destination for mail notification and REMCS notification has to be set in the Web-UI of the MMB. For the details on REMCS, see PRIMEQUEST 2000 series REMCS Service Manual (C122- E180). Video Redirection The video redirection function connects a unit to a partition from a remote terminal emulating the unit, which thus seems to be operated directly.
  • Page 97: Text Console Redirection

    It provides a function that will acquire memory dump into the disk partition dedicated to sadump if an error occurs on RHEL operating system. It enables investigation of the cause of error that occurred in the OS on the PRIMEQUEST 2000 series and therefore professional support can be obtained.
  • Page 98: Memory Dump Function (Windows)

    CHAPTER 4 Functions provided by the PRIMEQUEST 2000 series 4.13 Memory Dump Function (Windows) 4.13 Memory Dump Function (Windows) In Windows, the dump can be acquired using the standard functions of the OS. Before acquiring a dump, it is necessary to ensure the disk region in advance.
  • Page 99: Chapter 5 Partitioning

    (*1) In the PRIMEQUEST 2800B, components mounted in the cabinet can be used within one partition. In the PRIMEQUEST 2000 series, physical partitions with any number of resources can be configured in the granularity unit, in combination of the SB and IOU, using flexible I/O mode (*1).
  • Page 100: Partition Granularity

    CHAPTER 5 Partitioning 5.2 Physical Partitioning (PPAR) FIGURE 5.2 Conceptual diagram of the partitioning (PRIMEQUEST 2800E) 5.2.1 Partition granularity Partition granularity refers to the smallest unit of the components making up a partition. The names that indicate granularity include SB, IOU, DU and PCI_Box. The following table lists the partition granularity of the components that constitute a partition.
  • Page 101: Partition Configuration Rule

    CHAPTER 5 Partitioning 5.3 Extended Partitioning 5.2.2 Partition Configuration rule As a partition configuration rule, which is common to all models, specifies that the following condition must be satisfied. The partition should include at least one SB The partition should include at least one IOU If the above condition is not satisfied, power-on would be prohibited to the corresponding partition.
  • Page 102: Reserved Sb

    Then, the Memory Operation Mode and Reserved SB are set as needed. FIGURE 5.3 [Partition Configuration] screen For details on the setup procedure, see the “PRIMEQUEST 2000 Series Tool Reference” (C122-E177EN). Remarks The changes in the partition configuration are applied in the each partition unit when power cycled. The changes are not applied when rebooting the partition.
  • Page 103: Dynamic Reconfiguration Function

    Flexible I/O Mode The PRIMEQUEST 2000 series (except for 2800B) supports flexible I/O modes as I/ O connection modes. The flexible I/O function can configure a partition by combining any SB and IOU regardless of the mounting location.
  • Page 104 CHAPTER 5 Partitioning 5.9 Home SB PRIMEQUEST 2800B SB#0 is the Home SB. The Home SB cannot be selected and it can be seen which SB is the Home SB by MMB Web Home SB function Unlike the other SBs, the following functions are enabled on the Home SB. Legacy I / O Since the Legacy I/O function is enabled, only the USB ports and VGA port of the Home SB are available for use...
  • Page 105: Chapter 6 Redundancy

    This section describes the redundancy configuration of components. Redundancy In the PRIMEQUEST 2000 series, such as the memory, I/O, transmission paths, the power supply system and fan of the hardware configuration, most of the sections allow for redundancy, and achieve high reliability and high availability.
  • Page 106: Redundancy Of The Management Lan

    CHAPTER 6 Redundancy 6.4 Redundancy of the Management LAN 6.3.2 Redundancy of external storage In the PRIMEQUEST 2000 series, redundancy of external storage that stores the user data can be achieved by the following procedure. TABLE 6.2 Redundancy of external storage...
  • Page 107: Degradation Function

    CHAPTER 6 Redundancy 6.6 Degradation Function Degradation Function The degradation function disconnects (degradation) a faulty component when there is a hardware failure. To continue operation, it configures the system with the remaining hardware resources. The system is always restarted when using the degradation function. System operation can be resumed immediately without a prolonged system failure because the system is started with the faulty component disconnected.
  • Page 108: Chapter 7 Applicable Components For Hot Maintenance

    As a general rule, a field engineer carries out the hot maintenance. For details on the components to which hot maintenance can be applied and the redundant configurations, see 'Chapter 3 Component Configuration and Replacement (Addition and Removal) in the “PRIMEQUEST 2000 Series Administration Manual” (C122- E175EN).
  • Page 109: Overview Of Operations Management Tools

    The MMB Firmware controls the entire server system in linkage with the PRIMEQUEST 2000 series and other firmware (BIOS or BMC Firmware). The PRIMEQUEST 2000 series links with the MMB by communication with IPMI interface via the BMC, and by communication via an internal LAN.
  • Page 110: Command Line Interface (Cli)

    CHAPTER 8 Operations Management Tools 8.3 Video redirection In the PRIMEQUEST 2000 series, the system can be managed with the Web-UI functions utilizing the http/https protocol of the MMB, even without any special software for system management. The GUI can be operated from a remote PC through a Web browser.
  • Page 111: Table 8.1 List Of Svs Function Manuals

    OS or Linux OS, bundled software, etc. SVOM Health ServerView Suite Manual of SVOM for integrated management of Monitoring ServerView Operations Manager the [ (TBD)PRIMEQUEST 2000 series] and Server Management PRIMERGY SVOM Asset ServerView Suite Manual that provides an overview of the Asset...
  • Page 112: Uefi

    UEFI is an interface between the operating system and firmware, which controls the hardware in the place of BIOS. The UEFI is used as a boot firmware in the PRIMEQUEST 2000 series. The UEFI has a menu that offers operations including selective booting of the OS, starting the UEFI shell, and changing the settings of the boot options.
  • Page 113: Chapter 9 Server Maintenance

    This section describes the maintainability and preventive maintenance in the PRIMEQUEST 2000 series. Maintainability In the PRIMEQUEST 2000 series, hot maintenance can be applied to a PSU and fan while the system is running. The PCI Hot Plug function can also be used to enable hot maintenance of HHD and PCI Express card, thereby achieving high maintainability.
  • Page 114: Figure 9.1 [System Event Log] Screen

    Displaying the details of events displayed on the window, Click the [Detail] button. The [System Event Log (Detail)] window appears displaying the details of the events. For details on the Web-UI operation, see “PRIMEQUEST 2000 Series Tool Reference“(C122-E177EN). C122-B025-02EN...
  • Page 115: Chapter 10 Hardware Installation And Connection

    CHAPTER 10 Hardware Installation and Connection CHAPTER 10 Hardware Installation and Connection For details on the installation rack mounting and connection in the PRIMEQUEST 2000 series, see PRIMEQUEST 2000 Series Installation Manual (C122-E174EN). C122-B025-02EN...
  • Page 116: Appendix A Component Mounting Locations

    Appendix A Component Mounting Locations Appendix A Component Mounting Locations For details on the component mounting locations, see ‘Appendix B Physical mounting position and port number' in the “PRIMEQUEST 2000 Series Administration Manual” (C122-E175EN). C122-B025-02EN...
  • Page 117: Appendix B Mounting Locations, Bus Numbers, And Slot Numbers

    For details on the correspondence between the physical location and the BUS number of the built-in I/O, and between the mounting location and slot number in the PRIMEQUEST 2000 series, see 'Appendix D Physical Locations and BUS Numbers of Built-in I/Os, and PCI Slot Mounting Locations and Slot Numbers’ in the “PRIMEQUEST 2000 Series Administration Manual”...
  • Page 118: Appendix C Status Checks With Leds

    Appendix C Status checks with LEDs Appendix C Status checks with LEDs For details on the status check with LEDs in the PRIMEQUEST 2000 series, see 'Appendix F Status Check by LED' in the “PRIMEQUEST 2000 Series Administration Manual” (C122-E175EN)
  • Page 119: Appendix D Component Mounting Conditions

    Appendix D Component Mounting Conditions Appendix D Component Mounting Conditions For details on component mounting conditions, see ‘Appendix G Component Mounting Conditions' in the “PRIMEQUEST 2000 Series Administration Manual (” (C122-E175EN)’. C122-B025-02EN...
  • Page 120: Appendix E Cable (Specifications

    Appendix E Cable (Specifications Appendix E Cable (Specifications For details on cable specifications, see ‘Chapter 2 Connection Information’ in the PRIMEQUEST 2000 series Installation (Manual (C122-H007). C122-B025-02EN...
  • Page 121: Appendix F Tree Structure Of The Mib Provided With The Primequest 2000 Series

    Appendix F Tree Structure of the MIB provided with the PRIMEQUEST 2000 series For details on the MIB tree structure provided in the PRIMEQUEST 2000 series, see 'Appendix H MIB Tree Structure provided in the PRIMEQUEST 2000 series' in the “PRIMEQUEST 2000 Series Administration Manual” (C122-E175EN)’...
  • Page 122: Appendix G Linkage Functions And Services

    G.1 Linkage with Systemwalker Centric Manager Appendix G Linkage functions and Services This section describes the various linkage functions and services provided in the PRIMEQUEST 2000 series. Linkage with Systemwalker Centric Manager For details on the Linkage with Systemwalker Centric Manager, see 'Appendix J Linkage with Systemwalker Centric Manager' in the “PRIMEQUEST 2000 Series Administration Manual”...
  • Page 123: Appendix H Function List Supported By Os

    Appendix H Function list supported by OS G.2 Remote Customer Support System (REMCS) Appendix H Function list supported by OS This section describes whether OS supports EFI Aware, PCI Segment Mode, function related to TPM, respectively. Below table is shown it. EFI Aware/ Legacy Segment...

This manual is also suitable for:

Primequest 2400ePrimequest 2800ePrimequest 2800b

Table of Contents