PRIMEQUEST 2000 series. • For details on the operation of the main unit and other information, refer to the manuals for the PRIMEQUEST 2000 series main unit. • For details on the operating environment of software, refer to the website of each software program.
Page 6
Abbreviations in This Manual Name Abbreviation PRIMEQUEST 2400E 4 socket model PRIMEQUEST 2800B PRIMEQUEST 2000 series or PRIMEQUEST 8 socket model PRIMEQUEST 2800E Microsoft® Windows Server® 2012 R2 Standard Microsoft® Windows Server® 2012 R2 Datacenter Windows Server 2012 Microsoft® Windows Server® 2012 Standard Windows Microsoft®...
Page 7
PRIMEQUEST 2000 Series Administration Manual Administration Manual PRIMEQUEST 2000 Series Tool Reference Tool Reference PRIMEQUEST 2000 Series Linux Design Guide -Red Hat Enterprise Linux- Linux Design Guide PRIMEQUEST 2000 Series Linux Installation Guide -Red Hat Enterprise Linux- Linux Installation Guide •...
1. PRIMEQUEST Overview This chapter describes the overview of PRIMEQUEST. For details, refer to "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Up to 1 partition Up to 8 CPUs and 120 cores Up to 4 CPUs and 60 cores 8 CPUs and 120 cores Highly-reliable servers that are based on the latest Intel architecture PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
“Appendix B OS Specifications”. The maximum number of PCI slots depends on the type and the number of IO Units. For details, refer to "Chapter 1 Product Overview" in "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
1.3 Supported OS For the latest information on the supported OSs, refer to the following URL: http://www.fujitsu.com/global/services/computing/server/primequest/products/software/ PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
1.4 Component Names System Board Power Supply Unit (SB) (PSU)/FAN IO Unit (IOU) Management Board Disk Unit (DU) (MMB) Front Rear (View without the front panel) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Layout and Internal Connection Configuration for 2800B "1.5.1 Basic Configuration (2800B)" Layout and Internal Connection Configuration for 2400E "1.5.2 Basic Configuration (2400E)" Layout and Internal Connection Configuration for 2800E "1.5.3 Basic Configuration (2800E)" PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 14
1.5.1 Basic Configuration (2800B) (1/2) 2800B Layout Basic components Component Max. Installed as installable standard number (must be ordered) (must be ordered) (must be ordered) Front Rear AC cable (must be ordered) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 15
PCI Express slots on IOUs 16 cards (*1) (*1) Three cards per 10GbE IO Unit and four cards per 1GbE IO Unit For details on the configuration, refer to "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 16
1.5.2 Basic Configuration (2400E) (1/2) 2400E Layout Basic components Component Max. Installed as installable standard number (must be ordered) (must be ordered) (must be ordered) Front Rear AC cable (must be ordered) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 17
1GbE IO Unit * The number of available PCI Box slots depends on which type of IO Unit is selected. For details on the configuration, refer to "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 18
1.5.3 Basic Configuration (2800E) (1/2) 2800E Layout Basic components Component Max. Installed as installable standard number (must be ordered) (must be ordered) (must be ordered) Front Rear AC cable (must be ordered) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 19
1GbE IO Unit * The number of available PCI Box slots depends on which type of IO Unit is selected. For details on the configuration, refer to "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
•If a failure occurs in a partition, the hardware can protect other partitions from being affected by the failure. PCI Express PCI Express PCI Express PCI Express card card card card PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Flexible I/O [2400E/2800E Only] Partitioning does not have any limitations on the placement of SBs and IOUs. Flexible I/O enables the Reserved SB function by using alternative SBs. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
* Dynamic Reconfiguration as a hardware and firmware function of PRIMEQUEST supports online removal of SBs. However, as of when this manual is published, no OS vendor states availability of this function. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
A component that is stopped due to a failure can be replaced without stopping the operation of the partition. Original Dump Function For details, refer to "3.3 Key Points for I/O Configuration Design". This function collects system information when a problem occurs in the OS. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Partition redundancy that is based on an inter-cabinet cluster or an intra- cabinet cluster is supported. Boot Devices The following boot types are supported: •Internal HDD/SAS-SSD (RAID card) •HDD/SAS-SSD installed in a JX40 (RAID card) •iSCSI-SAN boot •FC-SAN boot •FCoE boot PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 25
This function directs the serial output from a partition to a terminal via a LAN. USB Port Disable Function • The front USB ports on the Home SB can be enabled or disabled in the BIOS menu. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 26
Reduction of Power Consumption •Power capping for PRIMEQUEST can automatically lower system performance so as to keep power consumption under pre-determined value. Compliant with RoHS Directive (Revision in September 2010) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
2. Basic Hardware Configuration This chapter describes the basic configuration of each component. For details, refer to "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
A sensor for monitoring suction temperature of the main unit is installed. System FRU A system FRU (I2C EEPROM) for storing the information of the main unit is installed. System LEDs Copyright 2014 FUJITSU LIMITED PRIMEQUEST 2000 Series Design Guide...
When multiple SBs are used to configure partitions, only the external ports of the Home SB are available. USB ports • USB 1.1/USB 2.0 x 4 (USB Type A) VGA port • VGA x 1 (D-sub 15pin) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 30
Intel® Xeon® processors are used. A QPI interface and memory controllers are integrated in these processors. It is possible to scale up the configuration by connecting CPUs via the QPI. CPUs Supported by the PRIMEQUEST 2000 Series Number of Product number...
Page 31
•At least one set of memory modules (two modules) must be installed for a CPU. Conditions for Installing Different CPUs Different types of CPUs can be installed in different PPAR blocks. (The CPUs must be supported in the PRIMEQUEST model.) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 32
PPAR installed in the blocks. same PPAR block. Flexible I/O Flexible I/O IOU#0 IOU#1 IOU#0 IOU#1 (*) The CPUs must be supported in the PRIMEQUEST model. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 33
SB#0 SB#1 SB#2 SB#0 SB#1 SB#2 This installation is not allowed because PPAR#0 is switched from SB#0 to SB#2 if a failure occurs in Flexible I/O Flexible I/O SB#0. IOU#0 IOU#0 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 34
Installation Group (1 CPU and Normal Mode) Installation group Memory slot numbers 0A0, 0A3 0A1, 0A4 0A2, 0A5 0B0, 0B3 0B1, 0B4 0B2, 0B5 1D2, 1D5 : Memory slots on an extended memory board PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 35
• When the Memory Spare function is used, install the same memory modules in all six slots of the same Memory Buffer. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 36
For details on installation order, refer to "G.2.1 DIMM mounting sequence" in "Administration Manual“ and the following slides. [Example of Installation Order] 1 CPU and Normal Mode (The same type of memory is shown in the same color.) Memory Installation CPU# slot# order PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 37
When only one CPU is installed, install the DIMMs in the slots starting from the smallest slot number on CPU#0. • Install DIMMs in pairs of two. Refer to the next slide when one PPAR block is configured with eight CPUs (Segment) or the Dynamic Reconfiguration function is used. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 38
When only one CPU is installed and the Dynamic Reconfiguration is enabled, the IOU- Dynamic Reconfiguration requires • memory installation for CPU#0 in the above order. • Install DIMMs in pairs of two. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 39
(8GB DIMM x 2) (*1) Memory rank: A unit of data input and output by a memory controller from the DRAM chips on a DIMM Memory access performance increases as the rank number increases. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Rank 1 Rank 1 DIMM A DIMM B DIMM C DIMM D DIMM E DIMM F * The available memory capacity is five-sixths of the total capacity of the installed memory. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
•Hardware setup (configuration change) function •Power control in the cabinet, sensor monitoring, partition configuration setting, Memory Mirror mode setting, and reset process •Collection and display of operation logs and error logs PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 42
This function prevents wrong operations and malicious operations on partitions. (Partition) (Partition) Management and monitoring MMB (One board is included in the default configuration. Another MMB can be added for redundancy.) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 43
•Port for maintenance x 1 Used by field engineers for maintenance. •COM port for an MMB console Used for initial setting. User ports Port for COM port for an MMB maintenance console PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
•To connect a PCI Box, install a PCI Box connection card in the specified PCI Express slot on the IOU. •1GbE IO Units and 10GbE IO Units can be installed together in the same cabinet. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 45
•Up to three PCI cards can be installed. (If the bracket size of the PCI card is full height, up to two cards can be installed.) 1GbE IO Unit 10GbE IO Unit PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 46
Connection to a backup Addition of LAN ports in external storage device Connection to an external hard cabinet (PRIMERGY SX05) a cluster configuration (ETERNUS) disk cabinet (JX40) PRIMERGY SX05 JX40 ETERNUS PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
IOU#0/IOU#2 RAID10 are supported. •A hot spare disk is supported. •Up to two RAID cards can be installed in a unit. For details on RAID configurations, refer to "3.3.4 HDD Configuration". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
LNKC: Abbreviation of a LINK Card. These cards are installed in PCI Boxes and are used to connect to IOUs. For details on the power supply configuration for a PCI Box, refer to "3.3.7 Power Supply Redundancy". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 49
IOU combinations and the available number of PCI slots Number of Number of Number of Available number of Model Number of PCNCs PCI Boxes 1GbE IO Units 10GbE IO Units slots (2400E/2800E only) 2800B 2400E 2800E PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 50
10GbE IO Units Connection to Different PCI Boxes Connection from Different Cabinets to a PCI Box * The connection configuration depends on the type of IO Unit that is to be installed. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 51
PCI Box is The PCI Box cannot be used Stop until it is repaired. repaired. For details on redundancy of PCI Express cards and connection destinations, refer to "3.3.5 Network Configuration". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
For details on the number of FANUs that must be installed and the installation slots, refer to "4.5.1 PSU Configuration" in "General Description". A total of six units between the PSUs and the FANUs are installed. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
2.9 Peripherals Configuration (1/4) Console Unit A PC is required to connect a console. For details, refer to "4.1 Key Points for Console Operation". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
For details on racks that can be installed and the use of rack products, contact your sales representative. How to Select Racks * Fujitsu recommends setting rack stabilizer against earthquakes with 80 gal or more. (3) Select a rack securing (4) Arrange options.
Page 56
PRIMEQUEST unit per rack. installed. (In some cases, two units can be installed.) PRIMERGY PRIMEQUEST unit (recommended) ETERNUS For details on devices that can be installed, visit our website at http://www.fujitsu.com/global/services/computing/server/primequest/products/peripheral/. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 57
C. Distance from the outside of the front rack posts to the inside of the rear door: 860mm or more Rear door Front door Front Posts Posts For details on rack installation conditions, refer to "Hardware Installation Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Management VLAN (IP addresses that can be switched between MMBs) environment For details, refer to "2.2 Key Points for the MMB Settings" in "Linux Installation Guide" and "3.3 Connection and Setting of MMB" in "Installation Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Switching Reserved SB Rules For details, refer to "3.2.3 Switching Reserved SB Rules". Configuration Example For details, refer to "3.2.4 Configuration Example". Guidelines for selecting a partition configuration Configuration examples for each model PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 61
* If an upper component is degraded, the lower components also cannot be used. (If an IOU is degraded, the DUs and PCI Boxes that are connected to the IOU are also degraded.) PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 62
(2SB-3CPU) cannot be installed. Partition configuration Total number of 2800B 2400E 2800E CPUs (Number of SBs per partition) One SB Two SBs Three SBs Four SBs Yes: Possible -: Not possible PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 63
Home SB. * If the Home SB is removed from the partition or is degraded, the SB with the lowest number in the partition is specified as the Home SB. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
SB#0 SB#0 SB#1 SB#2 SB#3 SB#1 SB#2 SB#3 IOU#0 IOU#1 IOU#2 IOU#3 IOU#0 IOU#1 IOU#2 IOU#3 Test environment partition Test environment partition : Home SB (Cannot be operated) : Reserved SB PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 65
MMB. • The partition configuration information for the last time a Reserved SB was operated is saved. • The saved information can be viewed from the MMB Web-UI. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 66
For a partition that consists of one SB, an SB with one or two CPUs can be set as a Reserved SB. Reserved SB Reserved SB Reserved SB Reserved SB SB#0 SB#1 SB#2 SB#3 SB#0 SB#1 SB#2 IOU#0 IOU#0 Partition#0 Partition#0 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 67
Different types Partition#0 Reserved SB settings that make a configuration violate the rules for installing different types of CPUs after an SB is replaced with a Reserved SB are not supported. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 68
Partition#0 Partition#1 When the Reserved SB is incorporated in partition#1, SB#0 SB#1 SB#2 the number of CPUs increases. Two CPU licenses are required for partition#1. Failed IOU#0 IOU#1 2CPU Partition#0 Partition#1 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 69
When using Reserved SBs, use NTP for time synchronization that is performed after switching. After the Home SB is switched, the connections of the external (VGA and USB) ports must be changed to the switched Home SB. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Hot addition of SBs and IOUs with the PCI Box LH modules is possible with supported OSs and models. Hot removal: Hot removal of IOUs with the PCI Box LH modules is possible with supported OSs and models. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 71
When the Home SB is switched to a Reserved SB, the SB with the lowest SB number among SBs including Reserved SBs is changed to the Home SB. For details on switching conditions, refer to "3.2.3 Reserved SB" in "Administration Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 72
Reserved SB new Home SB. : Home SB * The setting of SB#3 as the Reserved SB for partition#1 is : Reserved SB automatically cancelled when Reserved SB switching occurs. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 73
[Example] Multiple SBs (SB#2 and SB#3) Are Set as Reserved SBs for Partition#0. (If SB#1 Fails) Partition#1 Partition#0 Partition#1 Partition#0 SB#0 SB#0 SB#1 SB#2 SB#3 SB#1 SB#2 SB#3 IOU#0 IOU#1 IOU#2 IOU#3 IOU#0 IOU#1 IOU#2 IOU#3 : Home SB : Reserved SB PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 75
SB#2 SB#3 SB#1 SB#2 SB#3 IOU#0 IOU#1 IOU#2 IOU#3 IOU#0 IOU#1 IOU#2 IOU#3 Powered off Powered off Powered off Powered off Partition#2 : Home SB Cannot be used : Reserved SB PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 76
1 partition 1 to 2 partitions 2 partitions or more partitions Aggregation of PC servers and Core system reconstruction (open MF), UNIX server replacement, Work details higher reliability and DB server/ERP infrastructure PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 77
Number of partitions Number of CPU cores (*1) 24 - 240 Memory Mirror Cluster configuration Reserved SB (*1) Includes the number of CPU cores for Reserved SB Yes: Supported, - : Not supported PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 78
Clustering Cabinet#0 Cabinet#1 * Cabinet#0 and cabinet#1 have the same configuration. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 79
Reserved SB for partition#0, partition#1, and partition#2 to reduce the downtime at a failure. SB#0 SB#1 SB#2 SB#3 IOU#0 IOU#1 IOU#2 IOU#3 : Home SB : Reserved SB PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 80
(C) Example of a Configuration with Four SBs and Three Partitions nEight CPUs are installed in total. nMemory Mirror configuration nThree works are performed in different partitions. SB#0 SB#2 SB#3 SB#1 IOU#0 IOU#1 IOU#2 IOU#3 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 81
(D) Example of a Configuration with Three SBs and Two Partitions nSix CPUs are installed in total. nMemory Mirror configuration nPartition#0 contains two SBs to achieve redundancy for reliability. SB#0 SB#1 SB#2 IOU#0 IOU#1 IOU#2 IOU#3 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 82
3.2.4 Configuration Example - 2400E (E) Example of a Configuration with Two SBs and Two Partitions nThree CPUs are installed in total. nMemory Mirror configuration SB#0 SB#1 IOU#0 IOU#1 IOU#2 IOU#3 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 83
3.2.4 Configuration Example - 2800B (F) Example of a Configuration with Three SBs and One Partition nSix CPUs are installed in total. nMemory Mirror configuration SB#0 SB#2 SB#1 IOU#0 IOU#1 IOU#2 IOU#3 PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
"3.3.6 Setting I/O Space for PCI Devices". I/O space assignment setting Power Supply Redundancy For details, refer to "3.3.7 Power Supply Redundancy". Examples of primary power feed and dual power feed PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 85
It is recommended to use a redundant HDD (hardware RAID or software RAID) as a boot HDD. When an internal disk is used as a boot disk, RAID is configured by using ServerView Installation Manager (SVIM) to install an OS to the disk. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 87
Obtain an FBU installation kit (this kit uses Slot#0 exclusively) •FBUs cannot be connected to RAID cards that are installed in 10GbE IO Units, PCI Boxes, or Slot#3 on 1GbE IO Units. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 88
(*) A hardware RAID uses the cache on the hardware when Write Back or Always Write Back is specified. A disk uses the cache on the hardware when the disk cache is enabled. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 89
When using an internal HDD in an SB, note the following points. When the Reserved SB function is used, the HDD that is used as a boot drive and the data disks cannot be started or operated. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 90
For details, refer to "MegaRAID SAS User's Guide" and "ServerView RAID Manager User's Guide". SAN Boot An OS is started from a boot disk that is set in an external storage. For details, refer to "PRIMEQUEST 1000/2000 Series SAN Boot Environment Configuration Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 91
Work Windows Acquire memory dump Store to a save information destination STOP error For details, refer to "10.4.3 Setting up the dump environment (Windows)" in "Administration Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 92
(Installed memory + 512MB) capacity that is not managed with GDS (EXT3 file system) * Non-Fujitsu storage devices cannot be used for Acquisition area (Installed memory capacity + 1GB) / 0.9 dump areas for sadump. (1st generation) * Required for kdump (Installed memory capacity + 1GB) / 0.9...
* Specify different subnets for the management LAN, cluster LAN, internal LAN, and maintenance LAN. * When counting the number of LAN ports that are required for a partition, consider that two ports are used for the management LAN. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 94
When configuring partitions with multiple components, install internal ports on different components. Example of IOUs Separate IOUs from each other. IOU#0 IOU#1 PCI Express PCI Express Slots Slots Partition A Partition B PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 95
1000Base-T (Dual) Not used PCI Box LH FC card (Single) Duplicated Empty Duplicated PCI Box connection card 1000Base-T (Dual) PCI Box connection card Not used PCI Box LH FC card (Single) Empty PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 96
When MMBs are duplicated but user ports are not, the active MMB must be switched manually if an MMB fails. For details, refer to "1.3.3 Redundant configuration of the management LAN" in "Administration Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 97
10GbE environment is used. Infiniband cards can be used for the paths to synchronize databases. Use of Infiniband cards with PCIeSSDs can provide better effects within the network. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 98
PCH). The following devices can be assigned: Onboard LANs RAID cards in SBs RAID cards in DUs PCI Express slots on IOUs PCI Boxes PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 99
This type of assignment is easy to use and can be used when the partition configuration is relatively small and 16 or less devices require the I/O space. For details, refer to “3.4 [Device Manager] Menu" in "Tool Reference". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
* When using a redundant configuration or dual power feed for the main unit, also use the same power supply configuration for PCI Boxes. For details on PSU configurations, refer to "2.7 Power Supply Unit (PSU)". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 101
Power Calculator ("Tool"). As the above example shows, if the maximum apparent power is 4.500VA or less , the number of power distribution boxes can be reduced. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Windows => Windows Server Failover Clustering (WSFC) Improved reliability of SBs and QPI network RHEL => PRIMECLUSTER l Flexible I/O mechanism l Reserved SB (spare SB) Cost for Installation and Operation PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 103
"3.4.2 Intra-Cabinet Cluster". •Windows Clustering with Windows Server Failover Clustering (OS standard function) is recommended. * A server for Active Directory (AD server) is required separately. •Linux Clustering with PRIMECLUSTER is recommended. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 104
CPU frequency, memory capacity, HDD capacity, and number of HDDs). • If an IOU fails, the redundancy of the system is lost and components such as the midplane become single points of failure. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 105
• When Oracle SE-RAC is used, a cluster configuration is possible only for 2400E. For 2800E, Oracle SE-RAC cannot be used, but Oracle EE-RAC can be used. • When Oracle SE-RAC is used, only an intra-cluster configuration is possible for 2400E. • When Oracle EE-RAC is used, an inter-cluster configuration is possible. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 106
Cabinet#1 Cabinet#0 Partition#0 Partition#0 The cluster interconnect is configured separately from the operation LAN Cluster software Cluster software and management LAN. MMB#0 MMB#1 MMB#0 MMB#1 (Active) (Standby) (Active) (Standby) Management LAN PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 107
Operation LAN AD server Private network Public network (Operation LAN) Partition#Y Partition#X Cluster software Cluster software Partition#Y Partition#X Clustering Cluster service Cluster service (PRIMECLUSTER) Clustering MMB#0 MMB#1 (WSFC) (Active) (Standby) Management LAN PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
4. Operation Management Design This chapter describes the key points for designing operation management. For details, refer to "Administration Manual". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Text console Maintenance Management Action That Is Required When Reserved SB Switching Occurs If switching by the Reserved SB function occurs, the console connection must be changed. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 110
Console Connection Configuration Operation LAN : SW redundancy : Redundancy with teaming (PRIMECLUSTER GLS etc.) : Disabled on the standby side Video redirection Text console Remote storage Management LAN Maintenance LAN PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
•The same information is stored also in the flash memory of the MMB. •When duplicated MMBs are used, the same information is always stored in both MMBs. Backup Contents •Firmware setting information •Device identification information PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
(*2) Only for a SAN boot configuration with an ETERNUS disk storage system. Floppy disk drives cannot be connected to the PRIMEQUEST 2000 series. Select a method that does not require direct connection of a floppy disk drive. * The software support information is as of February 2014. For the latest software information, contact your sales representative.
* To ensure the stability of the NTP operation, specify multiple NTP System System clock clock servers from each NTP client. * Select NTP servers that have a high-precision clock in the Internet or intranet. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
5.1 Arrangement Information For details on the types of OSs and support, contact your sales representative. For details on OS specifications, refer to "Appendix B OS Specifications" and the website of each vendor. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
The tools below can be installed all together by using ServerView Installation Manager (SVIM). Tool Windows RHEL SUSE DSNAP Software Support Guide ServerView Operations Manager ServerView Agentless Service ServerView Agent ServerView RAID Manager Dynamic Reconfiguration utility Yes: Supported, -: Not supported PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 120
Drivers are provided with ServerView Suite. The latest versions can be downloaded from the following URL: http://www.fujitsu.com/global/services/computing/server/primequest/ Related Software Server Management Software For details, refer to "1.5.3 Server management software" in "General Description". PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Maximum file size: 16TB (implementation restrictions, the logical maximum value is 2^64-1 clusters) ReFS, which is the latest file system for Windows Server 2012, can be used for data areas, but ReFS is not recommended because its use has not been proven well. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 122
(*2) To install 1TB or more memory, Windows Server 2008 R2 SP1 must be applied. If SP1 is not available, apply KB980598. For details, refer to the KB information that is available from Microsoft (http://support.microsoft.com/kb/980598/). PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 123
- The number of LUNs for each of the lower-level drivers (mptsas, mptspi, lpfc, and megaraid_sas) cannot exceed the value that is set for the SCSI common layer. - To specify a non-default value, use the option parameter of each driver. PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 124
Maximum file size (EXT3) Maximum number of PCI slots All slots can be used. PCI Hot Plug PCI Box is supported. No IOU is supported. (Specification of the main unit) Firmware UEFI support Supported PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 125
Maximum volume capacity 64TB Maximum number of FC-HBAs Maximum number of physical For details, refer to "Networking Maximums" in NIC ports "Configuration Maximums for VMware vSphere 5.1". Firmware UEFI support Not Supported PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 126
Maximum volume capacity 64TB Maximum number of FC-HBAs Maximum number of physical For details, refer to "Networking Maximums" in NIC ports "Configuration Maximums for VMware vSphere 5.5". Firmware UEFI support Supported PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 127
Revision Record Revised location Description Edition Date 2014-02-18 All pages Created the first edition PRIMEQUEST 2000 Series Design Guide Copyright 2014 FUJITSU LIMITED...
Page 128