Failure 11: Low pressure switch failure
Reason: 1. Too low system pressure causes that the unit stops and the compressor protection works, the failure can
be resumed.
2. Pressure switch wire is not fixed well or in open circuit.
start
check if the connector
between pressure
switch and PCB is
fixed badly or damaged
(CN20 on PCB)
yes
replace pressure switch
connector, shut off and
be electrified again,
re-check
7. X Multi assistant Software
A ft er i nstal l at i on, you c an us e l apt op and Hai er devi c e GDGZ-01 to test system ,
software X-Multi assistant Software can help you diagnose system well or not.
check if the 2
straight lugs on
no
no
the pressure
switch work badly
yes
replace pressure
switch connector, shut
off and be electrified
again, re-check
-1
26-
if indoor fan motor
cannot startup normally
no
in heating mode(except
for defrost)
yes
check if the
no
indoor motor has
power input
replace main
control board
and check again
replace indoor
motor and check
again
Table of Contents