Haier AS072XVERA Operation And Installation Manual
Haier AS072XVERA Operation And Installation Manual

Haier AS072XVERA Operation And Installation Manual

Wall mounted type indoor units
Hide thumbs Also See for AS072XVERA:

Quick Links

R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER
WALL MOUNTED TYPE INDOOR UNITS
OPERATION & INSTALLATION MANUAL
Please read this manual carefully before using this air conditioner.
Please keep this manual safely for future use.
No.0010576789 B
AS072XVERA
AS092XVERA
AS122XVERA
AS182XVERA
Table of Contents
loading

Summary of Contents for Haier AS072XVERA

  • Page 1 R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER WALL MOUNTED TYPE INDOOR UNITS OPERATION & INSTALLATION MANUAL Please read this manual carefully before using this air conditioner. Please keep this manual safely for future use. No.0010576789 B AS072XVERA AS092XVERA AS122XVERA AS182XVERA...
  • Page 2: Table Of Contents

    Cautions ... Safety precautions... Parts and Functions ... Operation... Notes for safety ... Operation and Maintenance ... Trouble shooting ... Customer Need-to-know ... Instructions to installation ... When trouble happens... Failure code ... 8-18 21-22 24-29...
  • Page 3: Cautions

    Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 4: Cautions

    Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.
  • Page 5: Safety Precautions

    Safety precautions Carefully read the following information in order to operate the air conditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
  • Page 6 Safety precautions Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
  • Page 7 Safety precautions CAUTIONS ON INSTALLATION Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. Air-conditioner can't be installed in the envi- ronment with inflammable gases because the inflammable gases near to air-conditioner may...
  • Page 8: Parts And Functions

    Parts and Functions INDOOR UNIT FRONT VIEW INDOOR UNIT BACK VIEW Display board Signal receiver Heat preservation pipe Connecting pipes Drainage pipes Air inlet grille Front panel Louver Mounting plate...
  • Page 9 Parts and Functions REMOTE CONTROLLER YR-H65 TEMP HEALTH MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK TIMER STERILIZE LIGHT LOCK RESET CODE Power ON/OFF Used for unit start and stop. MODE Used to select AUTO run, COOL, DRY, HEAT and FAN operation. CLOCK Used to set correct time.
  • Page 10: Operation

    Operation Clock set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM"or "PM" flashes. Press to set correct time. Each press will increase or decrease 1 min . If the button is kept pressed, time will change quickly.
  • Page 11 Operation TEMP HEALTH MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK TIMER STERILIZE LIGHT LOCK RESET CODE Note: During Auto run operation, temp. setting will be shown in LCD display, unit will select heating, cooling or fan operation according to the room temp. Press ON/OFF button Unit starts running.
  • Page 12 Operation TEMP Remote HEALTH controller MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK TIMER STERILIZE LIGHT LOCK RESET CODE Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press, operation mode changes as follows: AUTO COOL DRY FAN...
  • Page 13 Operation TEMP HEALTH MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK TIMER STERILIZE RESET CODE LIGHT LOCK Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press, operation mode changes as follows: Remote AUTO COOL...
  • Page 14 Operation TEMP HEALTH MODE HEALTH AIRFLOW FRESH SLEEP SWING CLOCK TIMER STERILIZE RESET CODE LIGHT LOCK Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button. For each press,operation mode changes as follows: Remote AUTO COOL...
  • Page 15 Operation Note: For cooling only type, this function is invalid. TEMP HEALTH MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK TIMER STERILIZE LIGHT LOCK RESET CODE Press ON/OFF button Unit starts running. The previous status appears on the display (except. TIMER, SLEEP mode) Press MODE button.
  • Page 16: Air Flow Adjustment

    Operation Swing louvers (Vertical louvers) (Horizontal louvers) TEMP HEALTH MODE HEALTH AIRFLOW SLEEP FRESH SWING CLOCK TIMER STERILIZE RESET CODE LIGHT LOCK Side from side Swing Press SWING the vertical louvers move from side to side. Note: Put louvers at up position in cooling and down position in heating mode. This will be helpful to keep an even room temp.
  • Page 17: Remote Control Unit

    Operation Remote control unit Before go to bed, you can press the Sleep button, the air conditioner will operate in comfortable sleep mode to make your sleep more comfortable. Usage of the Sleep function After starting, set the Run mode and press the Sleep button.
  • Page 18: Timer Operation

    Operation Remote control unit TIMER operation Set Clock correctly before starting Timer operation (refer to page 2) You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1) After unit start, select your desired operation mode.
  • Page 19 Operation Remote controller operation (1) After unit start, select your desired operation mode. Operation mode will be displayed on LCD. (2) TIMER mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote 12:00 controller...
  • Page 20 Operation TEMP HEALTH MODE HEALTH AIRFLOW FRESH SLEEP SWING CLOCK STERILIZE TIMER LIGHT LOCK CODE RESET Health & Fresh Air operation Health operation After turning on the unit and set the desired working mode. Press the Health button, the LCD will display " health operation (start the negative ion generation device).
  • Page 21: Notes For Safety

    Never connect the earth wire with the gas pipe, water pipe, lightening arrester, or phone line. Do not spray any paint or insecticide on the air conditioner. Insecticide Never pour water on the indoor unit.
  • Page 22: Operation And Maintenance

    Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with clean and soft cloth. If air conditioner is very dirty, clean it with cloth soaked in neutral detergent, then wipe off the detergent with clean water.
  • Page 23: Trouble Shooting

    When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction.
  • Page 24 During heating,indoor fan is still running even unit is stopped. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Power supply switch is not in ON position.
  • Page 25: Customer Need-To-Know

    Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place.
  • Page 26: Instructions To Installation

    Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire. When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant within the refrigeration cycle.
  • Page 27: Preparation For Installation

    Improper placement of earth wires can result in electric shock. An electric leakage breaker must be installed, otherwise electric shock or other accidents would occur. After completion of the installation, the air conditioner shall be electrified to check for electric leakage. 2. Preparation for installation...
  • Page 28 Instructions to installation 5. Method for Cutting and Expanding Pipes. When the pipe is too long or the mouth is damaged, the pipe needs to cut or expanded. 1.cutting hose 2.Removing burr Hose Expander Correct Tilting cracks on expanded mouth 6.
  • Page 29 Instructions to installation Lid for right piping Lid for under piping Fix with adhesive tape 7. Other direction piping Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.
  • Page 30 Instructions to installation Incorrect address setting will cause abnormal to the system.and then put it down perpendicularly. Signal connecting cable must be sheilded type. 8. Indoor unit communication addresses setting CAUTION! FAIL TO DO THIS, THE UNIT WILL NOT WORK. 1.There are two methods to set the communication address A.
  • Page 31 Instructions to installation SW01 1 2 3 4 5 6 7 8 4. How to check the addresses? When finish all the above works, please power off and power on again to the whole system but set all the indoor units in STANDBY. Then continously press the emergency switch until you hear the buzzer sound 5 times(Pi Pi Pi Pi Pi), and then the LCD display board will show the address of this indoor unit.
  • Page 32: When Trouble Happens

    Insufficient cooling Sunlight direct into the room ? When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer.
  • Page 33: Failure Code

    Failure code TROUBLE SHOOTING Faulty temperature sensor Tai Faulty temperature sensor Tc1 Faulty temperature sensor Tc2 Faulty temperature sensor Tm Faulty EEPROM on indoor unit PCB Abnormal communication between indoor and outdoor unit Indoor unit address repeated Central control address repeated Faulty indoor unit fan motor Faulty driver of indoor unit fan motor...
  • Page 34 HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P.R.China Web Site: http://www.haier.com...

This manual is also suitable for:

As092xveraAs122xveraAs182xveraAs182avera

Table of Contents