Recommended Configuration Procedure; Configuring The Rmon Statistics Function; Configuring The Rmon Alarm Function - HP 830 Series Configuration Manual

Poe+ unified wired-wlan switch switching engine web-based
Hide thumbs Also See for HP 830 Series:
Table of Contents

Recommended configuration procedure

Configuring the RMON statistics function

The RMON statistics function can be implemented by either the Ethernet statistics group or the history
group, but the objects of the statistics are different, as follows:
A statistics object of the Ethernet statistics group is a variable defined in the Ethernet statistics table,
and the recorded content is a cumulative sum of the variable from the time the statistics entry is
created to the current time. Perform the tasks in
function.
A statistics object of the history group is the variable defined in the history record table, and the
recorded content is a cumulative sum of the variable in each period. Perform the tasks in
to configure RMON history statistics function.
Table 20 Configuring a RMON statistics group
Task
Configuring a statistics entry
Table 21 Configuring a RMON history group
Task
Configuring a history entry

Configuring the RMON alarm function

To send traps to the NMS when an alarm is triggered, configure the SNMP agent as described in
"Configuring
Perform the tasks in
Remarks
Required.
You can create up to 100 statistics entries in a statistics table.
After you create a statistics entry on an interface, the system collects
various traffic statistics on the interface, including network collisions, CRC
alignment errors, undersize/oversize packets, broadcasts, multicasts,
bytes received, and packets received. The statistics are cleared at a
reboot.
You can create only one statistics entry on one interface.
Remarks
Required.
You can create up to 100 history entries in a history table.
After an entry is created, the system periodically samples the number of
packets received/sent on the current interface. It saves the statistics as an
instance under the leaf node of the etherHistoryEntry table.
When you create an entry, if the value of the specified sampling interval is
identical to that of the existing history entry, the system considers their
configurations are the same and the creation fails.
SNMP" before configuring the RMON alarm function.
Table 22
to configure RMON alarm function.
Table 20
IMPORTANT:
IMPORTANT:
81
to configure RMON Ethernet statistics
Table 21

Hide quick links:

Table of Contents
loading

Table of Contents