HP 830 Series Configuration Manual page 394

Poe+ unified wired-wlan switch switching engine web-based
Hide thumbs Also See for HP 830 Series:
Table of Contents
Configuration procedure
Make sure that the IP address of the access device added on the portal server is the IP address of the
interface connected to the host (20.20.20.1 in this example), and the IP address group associated with
the access device is the subnet where the host resides (8.8.8.0/24 in this example).
Assign IP addresses to the host, switches, and servers as shown in
can reach each other.
Configure the RADIUS server to provide authentication and accounting functions for users.
Perform the following configuration on Switch A to implement cross-subnet portal authentication:
1.
Configure the RADIUS authentication server:
Select Authentication > RADIUS from the navigation tree.
a.
The RADIUS server configuration page appears, as shown in
b.
Select Authentication Server as the server type, enter the IP address 192.168.0.112 and port
number 1812, select active from the Primary Server Status list, and click Apply.
Figure 395 Configuring the RADIUS authentication server
2.
Configure a RADIUS accounting server:
On the RADIUS server configuration page, select Accounting Server as the server type, and enter
the IP address 192.168.0.112 and port number 1813, select active from the Primary Server Status
list, and click Apply.
382
Figure 394
and make sure that they
Figure
395.

Hide quick links:

Table of Contents
loading