Table 1-1. LCD Status Messages
Code
Text
E122C
CPU Power
Fault. Power
cycle AC.
E122D
Memory
Regulator #
Failed. Reseat
DIMMs.
E122E
On-board
regulator
failed. Call
support.
E1310
Fan ## RPM
exceeding
range. Check
fan.
E1311
Fan module ##
RPM exceeding
range. Check
fan.
E1313
Fan redundancy
lost. Check
fans.
E1410
Internal Error
detected.
Check "FRU X".
24
About Your System
(continued)
Causes
A power fault was
detected when powering
up the processor.
One of the memory
regulators has failed.
One of the on-board
voltage regulators failed.
RPM of specified fan is
outside of the intended
operating range.
RPM of specified fan in
specified module is
outside of intended
operating range.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.
Specified processor has an
internal error. The error
may or may not have been
caused by the processor.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 161.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 145.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 161.
See "Troubleshooting
System Cooling
Problems" on page 143.
See "Troubleshooting
System Cooling
Problems" on page 143.
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 144.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 161.