Cisco WS-C3524-PWR-XL-EN Installation Manual page 98

Installation guide
Hide thumbs Also See for WS-C3524-PWR-XL-EN:
Table of Contents
Table A-2
Technical Specifications for the Catalyst 3512, 3524, and 3548 XL Switches
Environmental Ranges
Operating
temperature
Storage
temperature
Relative
humidity
Operating
altitude
Storage altitude
Power Requirements
AC input
voltage
DC input
voltages
Power
consumption
Physical Dimensions
Weight
Dimensions (H x
D x W)
Catalyst 3500 Series XL Hardware Installation Guide
A-2
Catalyst 3512 XL
32 to 113°F (0 to 45°C)
–4 to 149°F (–10 to 65°C) –4 to 149°F (–10 to 65°C) –4 to 149°F (–10 to 65°C)
10 to 85%
(noncondensing)
Up to 10,000 ft (3000 m) Up to 10,000 ft (3000 m) Up to 10,000 ft (3000 m)
15,000 ft (4570 m)
100 to 127/200 to 240
VAC
(autoranging) 50 to 60 Hz
+5V
@8.0A,
12V
@0.5A
50W
171 Btus per hour
10.25 lb (4.65 kg)
1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)
Appendix A
Catalyst 3524 XL
32 to 113°F (0 to 45°C)
10 to 85%
(noncondensing)
15,000 ft (4570 m)
100 to 127/200 to 240
VAC
(autoranging) 50 to 60 Hz
+5V
@10A,
12V
@0.5A
75W
256 Btus per hour
8.5 lb (3.86 kg)
1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)
Technical Specifications
Catalyst 3548 XL
32 to 113°F (0 to 45°C)
10 to 85%
(noncondensing)
15,000 ft (4570 m)
100 to 127/200 to 240
VAC
(autoranging) 50 to 60 Hz
+3.3V
@17A
+12V
@1.1A
100W
342 Btus per hour
12 lb (5.45 kg)
1.73 x 15.34 x 17.5 in
(4.39 x 39.0 x 44.45 cm)
78-6456-04
Table of Contents
loading

Table of Contents