Heat pump water heater controller
Hide thumbs Also See for HP200M1-U1:

Quick Links

Heat Pump Water Heater
Controller Operation Guide
Models:
HP200M1-U1
HP250M1-U1
Power ON/OFF.
Mode selection. Press the MODE key to switch
between the four working modes of AUTO, ECO,
ELEC, and VAC.
Adjust the clock settings. Set the time of day in
hours/minutes.
Used to set timer functions/confirm changes to
settings.
Set the temperature and time. Press and hold
for continuous adjustment.
Turns a one-time boost heating function on or
off, using both the heat pump and back-up
electrical element, decreasing the heating time.
The heat pump will operate at any time to
provide hot water when the demand is required.
Operates the heat pump to provide hot water
only during the "off-peak" power period or
when there is an off-peak power signal. Manual
set time, Automatic off-peak signal or
Photovoltaic solar supplementary.
Will only use the electrical element for heating.
This function should only be used if there is a
fault with the heat pump module so that hot
water can be supplied to the user.
Vacation mode: Maintains a minimum water
temperature to save power, then reheats the
water in advance of the return date set by the
user.
Anti-Legionella, sterilizes your stored water
against Legionella, the service will automatically
turn on once every 7 days and raise the
temperature to 65°C, or as user defined.
Stored water temperature display. Bars indicate
temperature variations only and not water
volume.
Heat pump in operation indicator.
Electric heating in operation indicator.
Switching signal of the power supply is active.
HC
Supplementary photovoltaic (PV) solar power
PV
supply signal is active.
Lock screen display icon.
Table of Contents
loading

Summary of Contents for Haier HP200M1-U1

  • Page 1 Stored water temperature display. Bars indicate temperature variations only and not water volume. Models: Heat pump in operation indicator. HP200M1-U1 HP250M1-U1 Electric heating in operation indicator. Switching signal of the power supply is active. Supplementary photovoltaic (PV) solar power supply signal is active.
  • Page 2 Start Up Controls This guide is designed to better explain the controls and operation of the basic modes currently available to you with your Heat Pump Water Heater. Temperature and Time AUTO mode (Automatic operation) ELEC mode (Electric element) VAC mode (Vacation) BOOST function Lock screen Service mode (advanced settings)
  • Page 3: Auto Mode

    AUTO mode Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed to automatically operate the heat pump when the temperature has dropped by a specified amount, just like a thermostatically controlled hot water cylinder. AUTO Mode (under default settings) 1.
  • Page 4: Boost Function

    VAC mode Note: This mode is designed to maintain a minimum water temperature to conserve energy during a period of absence from the property. The unit automatically reheats the water in advance of the return date set. 1. Turn on the appliance by pressing the key if in Standby, otherwise disregard this step.
  • Page 5: Service Mode

    Service mode Note: Many of the features in service mode are for advanced configurations with connections to off-peak power switching or solar, however there are some settings in here that could be beneficial for adjustments to your system such as water sterilization, heat pump maximum working time, setting the day of the week and temperature differential.
  • Page 6: Fault Codes

    11. “ ” will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. – The hours can be adjusted between 5–15, the default is 10. Press key to cycle through settings. Press key to enter the next setting. _ _ _ _ _ _ _ _ _ _ _ 12.
  • Page 7 ECO Mode Controls This guide is designed to better explain the controls and operation of the three economy modes currently available to you with your Heat Pump Water Heater Manual timer Off-peak power signal Photovoltaic (PV) solar power Manual timer operation Note: This appliance must be connected to a power supply providing electricity 24 hours per day.
  • Page 8 10. “ ” will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with – Monday being 1 and Sunday being 7. Press key to cycle through settings. Press key to enter the next setting.
  • Page 9 Off-peak power signal Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed for situations where a meter (eg; smart meter) is constantly supplying electricity but automatically switches depending on peak hours. This is not suitable for situations and meters where tariff or ripple control turns off electricity supply for a period of time (peak.) Please engage your electrician or power provider for further information on the suitability of your...
  • Page 10 11. “ ” will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. – The hours can be adjusted between 5–15, the default is 10. Press key to cycle through settings. Press key to enter the next setting. _ _ _ _ _ _ _ _ _ _ _ 12.
  • Page 11 Photovoltaic (PV) solar power signal operation 1. Enter the Standby Mode by pressing the key, only the temperature and time will be displayed. 2. Press and hold the keys for 5 seconds to enter Service Mode. 3. “ ” will be displayed. The options are “NO” normally open (default) and “NC” normally closed. You must know if the signal from the switching device or solar controller are Normally Open or Normally Closed to meet this setting.
  • Page 12 12. “ ” will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with – Monday being 1 and Sunday being 7. Press key to cycle through settings. Press key to enter the next setting.
  • Page 13: Additional Functions

    Additional functions This guide is designed to better explain the controls and operation of additional functions and controls available with your Heat Pump Water Heater. Real-time parameter query Sterilization (Anti-legionella) Stored hot water display Demo (display) mode Parameter query Enter parameter query: 1.
  • Page 14 Stored hot water display This display indicates the temperature of water in the storage tank, not total volume. The hot water service is a pressurised system and should remain full of stored water. < 35℃ 35-40℃ 41-45℃ 46-50℃ 51-55℃ 56-75℃ Demo (Display) mode This display mode allows for certain display functions to be operational, whilst the appliance itself is not operating.