Mitsubishi Electric FR-A720-00030-NA Instruction Manual page 304

Table of Contents
Inverter
Forward
STF
rotation
Voltage/current
input switch
SD
0 to 5VDC
10
Frequency
2
setting
5
Connection diagram using
terminal 2 (0 to 5VDC)
Inverter
Forward
STF
Voltage/current
input switch
rotation
SD
0 to 10VDC
10E
Frequency
2
setting
5
Connection diagram
using terminal 2 (0 to 10VDC)
Inverter
Forward
rotation
STF
Terminal 4
AU
input selection
SD
DC0 to 5V
10
Frequency
4
setting
5
Connection diagram
using terminal 4 (0 to 5VDC)
(2) Perform operation by analog input voltage
 The frequency setting signal inputs 0 to 5VDC (or 0 to 10VDC) to across
the terminals 2 and 5. The 5V (10V) input is the maximum output
frequency. The maximum output frequency is reached when 5V (10V) is
input.
 The power supply 5V (10V) can be input by either using the internal
power supply or preparing an external power supply. The internal power
supply outputs 5VDC across terminals 10 and 5, or 10V across terminals
10E and 5.
Terminal
10
10E
 When inputting 10VDC to the terminal 2, set any of "0, 2, 4, 10, 12, 14"
in Pr. 73. (The initial value is 0 to 5V)
 Setting "1 (0 to 5VDC)" or "2 (0 to 10VDC)" in Pr. 267 and a voltage/
current input switch in the OFF position changes the terminal 4 to the
voltage input specification. When the AU signal turns ON, the terminal 4
input becomes valid.
Voltage/current
REMARKS
input switch
The wiring length of the terminal 10, 2, 5 should be 30m (98.4 feet) maximum.
Frequency/torque setting by analog
Inverter Built-in Power
Frequency Setting
Supply Voltage
Resolution
5VDC
0.030Hz/60Hz
10VDC
0.015Hz/60Hz
input (terminal 1, 2, 4)
Pr. 73 (terminal 2
input voltage)
0 to 5VDC input
0 to 10VDC input
293