Hitachi CIS02-H Operation Manual

Eco compact wired remote controller
Hide thumbs Also See for CIS02-H:

Quick Links

OPERATION MANUAL
Eco Compact
Wired Remote Controller
MODEL
CIS02-H
ORIGINAL INSTRUCTIONS
A16381TN6R
Table of Contents
loading

Summary of Contents for Hitachi CIS02-H

  • Page 1 – OPERATION MANUAL – Eco Compact Wired Remote Controller MODEL CIS02-H ORIGINAL INSTRUCTIONS A16381TN6R...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents 1. Safety Summary ................................1 2. Setting Names and Functions ............................7 3. Operation Method ................................8 3.1 Operation Mode (Cool, Heat, Dry, Cool and Heat Automatic and Fan Operation) ..........8 3.2 Temperature Setting ..............................9 3.3 Fan Speed Setting ..............................
  • Page 3 Table of Contents 5.4 Sleep Mode Details Setting ............................29 5.5 Operation Sound Setting ............................30 5.6 IR Receiver Setting ..............................31 6. Clock Setting ................................... 33 7. Operation Schedule Details Setting..........................35 8. Individual Louver Setting ............................... 37 8.1 Individual Louver Setting ............................37 8.2 Cancel Individual Louver Setting ..........................
  • Page 4: Safety Summary

    1. Safety Summary 1. Safety Summary Singal Words Indicates a hazardous situation that, if not avoided, could result in death or serious injury. Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury. Indicates information considered important, but not hazard-related (for example, messages relating to property damage).
  • Page 5 Use only Johnson Controls-Hitachi Air Conditioning recommended, provided as standardized, or replacement parts. • Johnson Controls-Hitachi Air Conditioning will not assume any liability for injuries or damage caused by not following steps outlined or described in this manual. Unauthorized modifications to Johnson Controls-Hitachi Air Conditioning products are prohibited as they…...
  • Page 6 1. Safety Summary Take the following precautions to reduce the risk of property damage. • Do not touch the main circuit board or electronic components in the controller or remote devices. Make sure that dust and/or steam does not accumulate on the circuit board. •...
  • Page 7 1. Safety Summary Installation Precautions Take the following precautions to reduce the risk of electric shock, fire, or explosion resulting in serious injury or death: • If the remote sensors are not used with this controller, then do not install this controller… ○...
  • Page 8 When shielded cabling is applied, proper bonding and termination of the cable shield is required as per Johnson Controls-Hitachi Air Conditioning guidelines. Plenum and riser ratings for communication cables must be considered per application and local code requirements.
  • Page 9 1. Safety Summary • Make sure that the terminals do not come into contact with the surface of the electrical box. If the terminals are too close to the surface, it may lead to failures at the terminal connection. • Do not pour water on the controller as it could cause electric shock and/or damage the unit.
  • Page 10: Setting Names And Functions

    2. Setting Names and Functions 2. Setting Names and Functions The figure below shows all the functions for reference. The actual display during operation is different. Display Part Current Time Set Temperature Operation Mode Louver Direction Fan Speed Run Indicator ON/OFF Button Directional Key Operation Mode Button...
  • Page 11: Operation Method

    3. Operation Method 3. Operation Method 3.1 Operation Mode (Cool, Heat, Dry, Cool and Heat Automatic and Fan Operation) Heat mode is only available when the indoor unit supports cooling and heating. Cooling only machine cannot support heating. 1. Operation mode setting Step1.
  • Page 12: Temperature Setting

    3. Operation Method 3.2 Temperature Setting 1. Temperature setting Step1. Home screen is displayed. Step2. By pressing " ", the temperature is increased by 0.5°C to a maximum of 30 By pressing " ", the temperature is decreased by 0.5°C. •...
  • Page 13: Fan Speed Setting

    3. Operation Method 3.3 Fan Speed Setting 1. This function is used to set fan speed. Step1. Home screen is displayed. Step2. Press " " to set "Fan Speed". The fan speed changes as below depending on the indoor unit type. Auto High High2...
  • Page 14: Louver Swing Direction

    3. Operation Method 3.4 Louver Swing Direction 1. This function is used to set the louver direction. LCD Indication COOL, DRY HEAT, FAN Step1. Press " " (On/Off). Make sure that the air conditioner is ON. Press " " and select "Louver Direction", refer to Auto-Swing "4.
  • Page 15: Operation

    3. Operation Method 3.5 Operation NOTES: • Once the temperature and Fan speed settings are set, the setting status is stored and does not need to be reset. • To change the settings, refer to Page 8 and Page 10. 3.5.1 Operation Start 1.
  • Page 16 3. Operation Method 3.5.2 Operation Stop 1. Operation stops. Step1. Press " " (On/Off). → The run indicator turns OFF and the operation stops. NOTE: • After the heating operation is stopped, it may continue to FAN operation for about 2 minutes.
  • Page 17: Icon Description

    3. Operation Method 3.6 Icon Description The status of the wired remote controller is displayed on the home screen. NOTE: • It may not be displayed depending on the type of outdoor unit or indoor unit you are using. Icon Description It is time to clean the air filter.
  • Page 18 3. Operation Method Icon Description This is the main remote controller setting. Use the main remote controller to set the main capacity control setting. In the case of a single unit, the main does not light up. In communication with the indoor unit. The on timer is set.
  • Page 19: Menu Operation

    4. Menu Operation 4. Menu Operation 1. Menu Display Step1. Press to display the menu screen. " " Step2. By pressing " " , the menu screen changes as below. Home Screen Louver Direction Simple Timer Setting GentleCool Comfort Setting Operation Schedule Setting AutoBoost Setting Sleep Mode Setting Capacity Control Setting...
  • Page 20: Simple Timer Setting

    4. Menu Operation 4.1 Simple Timer Setting This function is used to start or stop the unit operation at the set time. NOTES: • If clock has not been set, the On/Off setting will be skipped automatically. • When the wired remote controller is stopped, only "On Timer" can be set. And when the wired remote controller is ON, only "Off Timer"...
  • Page 21 4. Menu Operation • When the wired remote controller is OFF, set the "On Timer". Icon Set Value • The timer can be set from 0.5 to 23 hours. • Press " " or " " to increase or decrease 30 minutes of each step for 0.5 to 9.5 hours, 1 hour of each step for 10 to 23 hours.
  • Page 22: Gentlecool Comfort Setting

    4. Menu Operation 4.2 GentleCool Comfort Setting This function is used to suppress the indoor unit from blowing over cold air in cool mode. NOTES: • This function cannot be set when the indoor unit does not support this function. •...
  • Page 23: Capacity Control Setting

    4. Menu Operation 4.3 Capacity Control Setting This function is used to suppress the heating and cooling capacity of the outdoor unit. NOTES: • This function cannot be set when the indoor unit and outdoor unit do not support this function. •...
  • Page 24: Sleep Mode Setting

    4. Menu Operation 4.4 Sleep Mode Setting This function is used to get the air conditioner operation sleep-friendly. • When the sleep mode starts, "Off Timer" will be set. • After the sleep mode operates for a certain period of time, the setting temperature will be changed according to the selected operation mode as below table.
  • Page 25 4. Menu Operation 1. Set the sleep mode ON/OFF. Step1. Select "Sleep Mode Setting", refer to “4. Menu Operation”. Step2. Press " " or " " to switch the sleep mode between ON and OFF. Icon Set Value (ON: , OFF: Step3.
  • Page 26: Autoboost Setting

    4. Menu Operation 4.5 AutoBoost Setting This function is used to increase the cooling and heating capacity in 30 minutes once the operation starts. This function is only available when the operation mode is Cool or Heat. The unit starts each time in quick mode until the setting is canceled. NOTES: •...
  • Page 27: Operation Schedule Setting

    4. Menu Operation 4.6 Operation Schedule Setting This function is used to start or stop the unit operation at the set time. NOTES: • Scheduled operation (stop) is not possible when the remote control is prohibited. • If current time is not set, scheduled operation (stop) is not available. Refer to "6.
  • Page 28: Detailed Menu Operation

    5. Detailed Menu Operation 5. Detailed Menu Operation 1. Detailed Menu Display Step1. Press " " for 3 seconds to display the detailed menu screen. Step2. Press " " or " " to switch the item number: Set Value "0 1" ↔ "0 2" ↔ ... ↔ "0 6" Detailed item numbers are shown in the below table: Item No.
  • Page 29: Run Indicator Setting

    5. Detailed Menu Operation 5.1 Run Indicator Setting This function is used to turn on/off the run indicator. NOTE: • When this function is off, the run indicator cannot be lit during the operation. 1. Set the run indicator ON/OFF. Step1.
  • Page 30: Capacity Control Details Setting

    5. Detailed Menu Operation 5.2 Capacity Control Details Setting This function is used to set "Capacity Control Level". NOTES: • This function cannot be set when the indoor unit and outdoor unit do not support this function. • For how to set "Capacity Control" mode ON/OFF, please refer to "4. Menu Operation". 1.
  • Page 31: Gentlecool Comfort Details Setting

    5. Detailed Menu Operation 5.3 GentleCool Comfort Details Setting This function is used to set "GentleCool Comfort Level". NOTES: • This function cannot be set when the indoor unit does not support this function. • For how to set "GentleCool Comfort" mode ON/OFF, please refer to "4. Menu Operation". 1.
  • Page 32: Sleep Mode Details Setting

    5. Detailed Menu Operation 5.4 Sleep Mode Details Setting This function is used to set "Off Timer" in the sleep mode. NOTES: • The default value of "Off Timer" is 8 hours. • For how to set the sleep mode ON/OFF, please refer to "4. Menu Operation". 1.
  • Page 33: Operation Sound Setting

    5. Detailed Menu Operation 5.5 Operation Sound Setting This function is used to set the operation sound ON/OFF. 1. Set the operation sound ON/OFF. Step1. Enter "Operation Sound Setting" by selecting "0 5" as the item number, refer to "5. Detailed Menu Operation". Step2.
  • Page 34: Ir Receiver Setting

    5. Detailed Menu Operation 5.6 IR Receiver Setting The product (wired remote controller) has a built-in "IR Receiver" which can receive commands from the wireless remote controller(sold separately, model: CIR01). By pointing the transmitter of the wireless remote controller to this product, you can set temperature, operation mode, etc.
  • Page 35 5. Detailed Menu Operation NOTES: • The IR receiver function can only be used on the home screen. • The wired remote controller does not support "Differentiate Indoor Units Set Close Together" at the wireless remote controller. • The wired remote controller does not support "Test Run" at the wireless remote controller. •...
  • Page 36: Clock Setting

    6. Clock Setting 6. Clock Setting This function is set the date and time. NOTES: • The clock accuracy is within ±70 seconds each month. It is recommended to set the clock to the current time on regular basis. • The clock can run for 72 hours even if the electricity is cut off.
  • Page 37 6. Clock Setting Step2. Set the clock in the order of "Year" ↔ "Month" ↔ "Day" ↔ "Hour" ↔ "Minute". Press " " or " " to change the settings of selected item, and press " " to switch to the next item. Set Value (Year) Set Value (Month) Set Value (Day)
  • Page 38: Operation Schedule Details Setting

    7. Operation Schedule Details Setting 7. Operation Schedule Details Setting This function is set the schedule timer ("On Timer" and "Off Timer") and the weekly schedule. NOTE: • For how to set the operation schedule ON/OFF, please refer to "4. Menu Operation". 1.
  • Page 39 7. Operation Schedule Details Setting Step4. "Off Timer" screen is displayed. Set Value (Hour) Press " " or " " to set the time. Set Value (Minute) Press " " to switch between "Hour" and "Minute". Icon ( Off Timer) Step5.
  • Page 40: Individual Louver Setting

    8. Individual Louver Setting 8. Individual Louver Setting This function is to individually set the air direction of multiple air outlets. NOTES: • This function is available when the indoor unit supports individual louvers. • It cannot be set while the air conditioner is stopped. •...
  • Page 41: Cancel Individual Louver Setting

    8. Individual Louver Setting Press " " or " " to select the indoor unit by changing the index number. Then press " " to confirm the selection. • If all the indoor units are selected, the "Index No." will be indicated as FF.
  • Page 42: Filter Reminder Reset Setting

    9. Filter Reminder Reset Setting 9. Filter Reminder Reset Setting This function is used to turn off the filter reminder indication and to reset the time of use for the filter. NOTE: • When it is time to clean the air filter, " "...
  • Page 43: Power Failure

    10. In Alarm Condition 10.1 Power Failure • All the indicators are OFF. • Once the air conditioner is stopped by power failure for longer than 2 seconds, the air conditioner is not started again, although power recovers. Perform the starting procedures again. •...
  • Page 44 © 2023 Hitachi-Johnson Controls Air Conditioning, Inc. 2023.05 Ver.A Printed in China...

Table of Contents